Improving the quality of biomarker candidates in untargeted metabolomics via peak table-based alignment of comprehensive two-dimensional gas chromatography-mass spectrometry data

被引:41
作者
Bean, Heather D. [1 ]
Hill, Jane E. [1 ]
Dimandja, Jean-Marie D. [2 ]
机构
[1] Dartmouth Coll, Thayer Sch Engn, Hanover, NH 03755 USA
[2] Spelman Coll, Dept Chem & Biochem, Atlanta, GA 30314 USA
关键词
Comprehensive two-dimensional gas chromatography; GC x GC-MS; Data alignment; Untargeted metabolomics; Biomarker; CHEMOMETRIC ANALYSIS; SEPARATIONS; METABOLITES; DISCOVERY;
D O I
10.1016/j.chroma.2015.03.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The potential of high-resolution analytical technologies like GC x GC/TOF MS in untargeted metabolomics and biomarker discovery has been limited by the development of fully automated software that can efficiently align and extract information from multiple chromatographic data sets. In this work we report the first investigation on a peak-by-peak basis of the chromatographic factors that impact GC x GC data alignment. A representative set of 16 compounds of different chromatographic characteristics were followed through the alignment of 63 GC x GC chromatograms. We found that varying the mass spectral match parameter had a significant influence on the alignment for poorly-resolved peaks, especially those at the extremes of the detector linear range, and no influence on well-chromatographed peaks. Therefore, optimized chromatography is required for proper GC x GC data alignment. Based on these observations, a workflow is presented for the conservative selection of biomarker candidates from untargeted metabolomics analyses. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:111 / 117
页数:7
相关论文
共 29 条
[11]   Model-based peak alignment of metabolomic profiling from comprehensive two-dimensional gas chromatography mass spectrometry [J].
Jeong, Jaesik ;
Shi, Xue ;
Zhang, Xiang ;
Kim, Seongho ;
Shen, Changyu .
BMC BIOINFORMATICS, 2012, 13
[12]   Comparative Analysis of Mass Spectral Similarity Measures on Peak Alignment for Comprehensive Two-Dimensional Gas Chromatography Mass Spectrometry [J].
Kim, Seongho ;
Zhang, Xiang .
COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2013, 2013
[13]   An optimal peak alignment for comprehensive two-dimensional gas chromatography mass spectrometry using mixture similarity measure [J].
Kim, Seongho ;
Fang, Aiqin ;
Wang, Bing ;
Jeong, Jaesik ;
Zhang, Xiang .
BIOINFORMATICS, 2011, 27 (12) :1660-1666
[14]   Semi-automated non-target processing in GC x GC-MS metabolomics analysis: applicability for biomedical studies [J].
Koek, Maud M. ;
van der Kloet, Frans M. ;
Kleemann, Robert ;
Kooistra, Teake ;
Verheij, Elwin R. ;
Hankemeier, Thomas .
METABOLOMICS, 2011, 7 (01) :1-14
[15]   Quantitative metabolomics based on gas chromatography mass spectrometry: status and perspectives [J].
Koek, Maud M. ;
Jellema, Renger H. ;
van der Greef, Jan ;
Tas, Albert C. ;
Hankemeier, Thomas .
METABOLOMICS, 2011, 7 (03) :307-328
[16]   Tile-based Fisher-ratio software for improved feature selection analysis of comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry data [J].
Marney, Luke C. ;
Siegler, W. Christopher ;
Parsons, Brendon A. ;
Hoggard, Jamin C. ;
Wright, Bob W. ;
Synovec, Robert E. .
TALANTA, 2013, 115 :887-895
[17]   Trends in data processing of comprehensive two-dimensional chromatography: State of the art [J].
Matos, Joao T. V. ;
Duarte, Regina M. B. O. ;
Duarte, Armando C. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 910 :31-45
[18]  
Mostafa A, 2013, LC GC EUR, V26, P672
[19]   Optimization aspects of comprehensive two-dimensional gas chromatography [J].
Mostafa, Ahmed ;
Edwards, Matthew ;
Gorecki, Tadeusz .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1255 :38-55
[20]   Comprehensive multidimensional separations for the analysis of petroleum [J].
Nizio, Katie D. ;
McGinitie, Teague M. ;
Harynuk, James J. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1255 :12-23