Inferior vena cava filter tilting between placement and retrieval is associated with caval diameter and need for complex retrieval techniques

被引:6
作者
Laidlaw, Grace L. [1 ]
Chick, Jeffrey Forris Beecham [1 ]
Ingraham, Christopher R. [1 ]
Monroe, Eric J. [2 ]
Johnson, Guy E. [1 ]
Valji, Karim [1 ]
Shin, David S. [1 ]
机构
[1] Univ Washington, Sect Vasc & Intervent Radiol, Dept Radiol, 1959 Northeast Pacific St, Seattle, WA 98195 USA
[2] Univ Wisconsin, Sect Vasc & Intervent Radiol, Dept Radiol, 1675 Highland Ave, Madison, WI 53792 USA
关键词
IVC filter; Filter tilt; Advanced retrieval technique; COMPLICATIONS; GUIDELINES;
D O I
10.1016/j.clinimag.2021.07.019
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Inferior vena cava (IVC) filter tilt may lead to apex embedment and need for advanced retrieval techniques. This study assesses factors associated with filter tilt change over time and need for complex retrieval procedures. Materials and methods: 252 consecutive patients underwent retrievable IVC filter placement and removal at a single academic institution over 58 months. 182 (72.2%) patients met inclusion criteria. IVC filters included 168 (92.3%) Gunther Tulip and 14 (7.7%) Option filters. The primary outcome was medial-to-lateral IVC filter tilt change between placement and retrieval. Secondary outcomes included advanced retrieval technique use and multiple retrieval attempts. Independent variables included demographics, IVC diameter, filter hook position relative to the renal veins, and dwell time. Associations were determined using student's t-tests, ANOVA, and linear and logistic regressions. Results: Mean IVC diameter at placement was 19.2 +/- 3.3 mm. Mean filter tilts at placement and retrieval were 6.1 +/- 4.9 degrees and 5.2 +/- 5.0 degrees, respectively. Mean tilt change was 5.0 +/- 5.0 degrees. Larger IVC diameter was associated with greater filter tilt change (p = 0.0004). While IVC diameter did not independently predict retrieval difficulty, greater tilt change and prolonged dwell time were associated with increased advanced retrieval technique use (p = 0.01 and 0.002, respectively). Results were unchanged in a subgroup analysis of patients treated with Gunther Tulip filters. Conclusion: Larger IVC diameter predicts increased filter tilt change, which in turn is associated with challenging retrievals. Attention to IVC diameter during filter placement may anticipate tilt-related complications.
引用
收藏
页码:243 / 248
页数:6
相关论文
共 20 条
  • [11] Antithrombotic Therapy for VTE Disease CHEST Guideline and Expert Panel Report
    Kearon, Clive
    Akl, Elie A.
    Ornelas, Joseph
    Blaivas, Allen
    Jimenez, David
    Bounameaux, Henri
    Huisman, Menno
    King, Christopher S.
    Morris, Timothy A.
    Sood, Namita
    Stevens, Scott M.
    Vintch, Janine R. E.
    Wells, Philip
    Woller, Scott C.
    Moores, Lisa
    [J]. CHEST, 2016, 149 (02) : 315 - 352
  • [12] An analysis of factors associated with increased fluoroscopy time or the need for complex techniques at IVC filter retrieval
    Kleedehn, Mark
    Moore, Kelli
    Longo, Katherine
    Woo, Kaitlin
    Laeseke, Paul
    [J]. EUROPEAN RADIOLOGY, 2019, 29 (04) : 1931 - 1938
  • [13] Analysis of tilt of the Gunther tulip filter
    Sag, Alan A.
    Stavas, Joseph M.
    Burke, Charles T.
    Dixon, Robert G.
    Marquess, Joel S.
    Mauro, Matthew A.
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (05) : 669 - 676
  • [14] Complications of inferior vena cava filters
    Sella, David M.
    Oldenburg, W. Andrew
    [J]. SEMINARS IN VASCULAR SURGERY, 2013, 26 (01) : 23 - 28
  • [15] Stratification, Imaging, and Management of Acute Massive and Submassive Pulmonary Embolism
    Sista, Akhilesh K.
    Kuo, William T.
    Schiebler, Mark
    Madoff, David C.
    [J]. RADIOLOGY, 2017, 284 (01) : 5 - 24
  • [16] Long-term Retrieval Success Rate Profile for the Gunther Tulip Vena Cava Filter
    Smouse, H. Bob
    Rosenthal, David
    Van Ha, Thuong
    Knox, Michael F.
    Dixon, Robert G.
    Voorhees, William D., III
    McCann-Brown, Jennifer A.
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (07) : 871 - 877
  • [17] Embedded inferior vena cava filter removal: Use of endobronchial forceps
    Stavropoulos, S. William
    Dixon, Robert G.
    Burke, Charles T.
    Stavas, Joseph M.
    Shah, Anand
    Shlansky-Goldberg, Richard D.
    Trerotola, Scott O.
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (09) : 1297 - 1301
  • [18] Medical progress: Acute pulmonary embolism
    Tapson, Victor F.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2008, 358 (10) : 1037 - 1052
  • [19] Complications and Retrieval Data of Vena Cava Filters Based on Specific Infrarenal Location
    Tullius, Thomas G., Jr.
    Bos, Aaron S.
    Patel, Mikin V.
    Funaki, Brian
    Van Ha, Thuong G.
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 41 (02) : 239 - 244
  • [20] von Elm E, 2008, J CLIN EPIDEMIOL, V61, P344, DOI [10.1016/j.jclinepi.2007.11.008, 10.2471/BLT.07.045120]