Bond behavior between deformed steel bars and recycled aggregate concrete after freeze-thaw cycles

被引:43
作者
Liu, Kaihua [1 ]
Yan, Jiachuan [2 ,3 ]
Meng, Xiangxin [4 ]
Zou, Chaoying [2 ,3 ]
机构
[1] Guangdong Univ Technol, Sch Civil & Transportat Engn, Guangzhou 510006, Peoples R China
[2] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150090, Peoples R China
[3] Harbin Inst Technol, Key Lab Smart Prevent & Mitigat Civil Engn Disast, Minist Ind & Informat Technol, Harbin 150090, Peoples R China
[4] HIT, Architectural Design & Res Inst, Harbin 150090, Peoples R China
基金
中国国家自然科学基金;
关键词
Bond behavior; Recycled aggregate concrete; Freeze-thaw cycles; Bond strength; Bond stress-slip; RESISTANCE; DURABILITY;
D O I
10.1016/j.conbuildmat.2019.117236
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In cold regions, freeze-thaw damage can deteriorate the structural performance of reinforced concrete structures. This paper investigated the bond behavior between recycled aggregate concrete (RAC) and deformed steel bars after freeze-thaw cycles (FTCs). Sixty-three specimens for pull-out tests were prepared with three different recycled coarse aggregate replacement ratios (0%, 30% and 50%) and seven different FTCs (0, 50, 100, 150, 200, 250 and 300). Additionally, nine made-to-measure pull-out specimens with built-in strain gauges were tested to tentatively study the bond stress distribution along the interface between the steel bars and the RAC after the FTCs. The results show that as the FTCs increased, the bond strength decreased and became increasingly significant as the RCA replacement ratios increased, while the bond slip was relatively stable as the FTCs increased and exhibited a similar increasing trend for all the mixtures at the higher number of FTCs. The bond stress focused on local areas and formed local stress concentrations when the pull-out force was close to the peak value. Finally, a two-segment bond stress-slip model to describe the bond behavior between RAC with RCA replacement ratios less than 50% and deformed steel bars after FTCs was proposed, showing a good correlation with the test results. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:12
相关论文
共 35 条
[1]  
Abbas A., MAT CHARACT, V60
[2]   Durability of recycled aggregate concrete designed with equivalent mortar volume method [J].
Abbas, Abdelgadir ;
Fathifazl, Gholamreza ;
Isgor, O. Burkan ;
Razaqpur, A. Ghani ;
Fournier, Benoit ;
Foo, Simon .
CEMENT & CONCRETE COMPOSITES, 2009, 31 (08) :555-563
[3]   Construction and demolition waste generation and properties of recycled aggregate concrete: A global perspective [J].
Akhtar, Ali ;
Sarmah, Ajit K. .
JOURNAL OF CLEANER PRODUCTION, 2018, 186 :262-281
[4]   Freeze-thaw resistance of concrete produced with fine recycled concrete aggregates [J].
Alexandre Bogas, J. ;
de Brito, J. ;
Ramos, Duarte .
JOURNAL OF CLEANER PRODUCTION, 2016, 115 :294-306
[5]   REINFORCEMENT ANCHORAGE SLIP UNDER MONOTONIC LOADING [J].
ALSIWAT, JM ;
SAATCIOGLU, M .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1992, 118 (09) :2421-2438
[6]  
[Anonymous], 2006, 522006 JGJ CHIN IND
[7]  
[Anonymous], 2009, 500822009 GBT CHIN N
[8]  
[Anonymous], 2004, CAN3A233 CSA
[9]  
[Anonymous], 2008, Building code requirements for structural concrete
[10]  
[Anonymous], 2010, 251772010 GBT CHIN N