Real-time correction of magnetic field inhomogeneity-induced image distortions for MRI-guided conventional and proton radiotherapy

被引:43
作者
Crijns, S. P. M. [1 ]
Raaymakers, B. W. [1 ]
Lagendijk, J. J. W. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiotherapy, NL-3584 CX Utrecht, Netherlands
关键词
FEASIBILITY;
D O I
10.1088/0031-9155/56/1/017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Image-guided radiotherapy has the potential to increase the success of treatment by decreasing uncertainties concerning tumour position and shape. We pursue integrated diagnostic quality MRI functionality with radiotherapy systems to boost the possibilities of image guidance by providing images with superior soft-tissue contrast during treatment. However, the use of MR images in radiotherapy can be hindered by geometrical distortions due to magnetic field inhomogeneity problems. A method for fast correction of these distortions is presented and implemented. Using a 20 cm square phantom containing a regular grid, a measure of residual deformation after correction is established. At very low gradient strength (which leads to large deformations) a maximum displacement of 2.9 mm is shown to be reduced to 0.63 mm. Next, the method is applied in vivo to the case of pelvic body contour extraction for prostate radiotherapy treatment planning. Here, again with low gradient strengths, distortions of up to 6 mm can be reduced to 2 mm. All results are provided within a lag time of 8 ms. We discuss implications of image distortions for MRI-guided photon and proton radiotherapy separately, since the dose-depth curves in these treatments are very different. We argue that, although field inhomogeneities cannot be prevented from occurring, distortion correction is not always necessary in practice. This work opens new possibilities for investigating on-line MRI-based plan adaptations and ultimately MRI-based treatment planning.
引用
收藏
页码:289 / 297
页数:9
相关论文
共 25 条
[1]   A two-step scheme for distortion rectification of magnetic resonance images [J].
Baldwin, Lesley N. ;
Wachowicz, Keith ;
Fallone, B. Gino .
MEDICAL PHYSICS, 2009, 36 (09) :3917-3926
[2]   A device for realtime 3D image-guided IMRT [J].
Dempsey, JF ;
Benoit, D ;
Fitzsimmons, JR ;
Haghighat, A ;
Li, JG ;
Low, DA ;
Mutic, S ;
Palta, JR ;
Romeijn, HE ;
Sjoden, GE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02) :S202-S202
[3]   A complete distortion correction for MR images: I. Gradient warp correction [J].
Doran, SJ ;
Charles-Edwards, L ;
Reinsberg, SA ;
Leach, MO .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (07) :1343-1361
[4]   First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system [J].
Fallone, B. G. ;
Murray, B. ;
Rathee, S. ;
Stanescu, T. ;
Steciw, S. ;
Vidakovic, S. ;
Blosser, E. ;
Tymofichuk, D. .
MEDICAL PHYSICS, 2009, 36 (06) :2084-2088
[5]   Real-time 2D parallel windowed Fourier transform for fringe pattern analysis using Graphics Processing Unit [J].
Gao, Wenjing ;
Huyen, Nguyen Thi Thanh ;
Loi, Ho Sy ;
Kemao, Qian .
OPTICS EXPRESS, 2009, 17 (25) :23147-23152
[6]   Validation of functional imaging with pathology for tumor delineation in the prostate [J].
Groenendaal, Greetje ;
Moman, Maaike R. ;
Korporaal, Johannes G. ;
van Diest, Paul J. ;
van Vulpen, Marco ;
Philippens, Marielle E. P. ;
van der Heide, Uulke A. .
RADIOTHERAPY AND ONCOLOGY, 2010, 94 (02) :145-150
[7]  
Haacke E.M., 1999, Magnetic Resonance Imaging: Physical Principles and Sequence Design
[8]   Fast, automated, N-dimensional phase-unwrapping algorithm [J].
Jenkinson, M .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) :193-197
[9]  
Karasev Peter A., 2007, 2007 IEEE Radar Conference, P574, DOI 10.1109/RADAR.2007.374282
[10]   Treatment plan adaptation for MRI-guided radiotherapy using solely MRI data: a CT-based simulation study [J].
Kerkhof, E. M. ;
Balter, J. M. ;
Vineberg, K. ;
Raaymakers, B. W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (16) :N433-N440