Navigation for placement of scaphoid screws.: A new indication for intraoperative 3D navigation -: a cadaver study

被引:14
作者
Kendoff, D.
Citak, M.
Gaulke, R.
Gardner, M. J.
Geerling, J.
Krettek, C.
Huefner, T.
机构
[1] Hannover Med Sch, Unfallchirurg Klin, D-30625 Hannover, Germany
[2] Hosp Special Surg, Dept Orthopaed, New York, NY 10021 USA
来源
UNFALLCHIRURG | 2007年 / 110卷 / 09期
关键词
scaphoid screw; 3D navigation; computer-assisted surgery; reference tracker;
D O I
10.1007/s00113-007-1280-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction Up to now, the use of navigation systems for the placement of scaphoid screws has been impossible, mainly because there have been no ways of fixing the reference markers. Faulty placement rates in internal fixation of the scaphoid show there is a current need for a 3D image-based navigation system and intraoperative monitoring of how successful the procedure will be. For this reason, we have developed a new radiotransparent hand fixation device (Scaph-Splint (R)), which allows reliable and accurate drilling of the scaphoid using 3D navigation. Tests of this device and the simultaneous precise placement of screws securing an internal fixation device are described in this paper. Material and Methods Relative movements between the wrist and fixation device were measured with a 3-D ultrasound motion analyser system. Five cadaveric upper extremity specimens were then used for further navigated test applications. Each specimen was placed in the fixation device, and both the forearm and hand were secured to the two surfaces, with the wrist in approximately 80 degrees of extension. A reference marker was then securely fixed to the fixation device. A commercial navigation system and 3-D fluoroscopic imaging were used for each trial. Under navigation, the scaphoid was drilled in retrograde fashion, and a screw was placed into the drilled hole. Following screw placement, a 3D scan was performed to evaluate its position. The screw placement was analysed blindly to optimal placement and drill or screw perforation, and the image quality was rated on a visual analog scale (VAS). Results There were few artefacts, and the image quality of the 3-D scan was judged as as good (VAS 7-9). Deviations of >= N0.2 mm between planned trajectory and drilling tunnal were not found in any of the specimens; there were deviations of >= 1 mm in one case, and all other cases showed deviations of >= 1 mm. There were no registration failures of the navigation system, indicating that no loosening of the reference marker or movement of the hand occurred. There was one case of scaphoid perforation at the distal pole. Discussion We found that the Scaph-Split allowed complete immobilisation of the hand and carpus. This allowed for adequate reference tracker stability and subsequent successful 3D navigated fluoroscopic drilling and screw placement in the scaphoid. While further tests on fresh-frozen cadavers is warranted, this technique may prove clinically to be very useful for surgeons treating scaphoid fractures.
引用
收藏
页码:745 / 750
页数:6
相关论文
共 20 条
[1]   TECHNICAL FACTORS RELATED TO HERBERT SCREW FIXATION [J].
ADAMS, BD ;
BLAIR, WF ;
REAGAN, DS ;
GRUNDBERG, AB .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1988, 13A (06) :893-899
[2]   Measurement of the scaphoid humpback deformity using longitudinal computed tomography: Intra- and interobserver variability using various measurement techniques [J].
Bain, GI ;
Bennett, JD ;
MacDermid, JC ;
Slethaug, GP ;
Richards, RS ;
Roth, JH .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (01) :76-81
[3]  
Citak M, 2006, Technol Health Care, V14, P473
[4]  
Citak M, 2006, Comput Aided Surg, V11, P209, DOI 10.1080/10929080600890015
[5]   Should acute scaphoid fractures be fixed? A randomized controlled trial [J].
Dias, JJ ;
Wildin, CJ ;
Bhowal, B ;
Thompson, JR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (10) :2160-2168
[6]  
Frahm R, 1992, Handchir Mikrochir Plast Chir, V24, P62
[7]   Does computer-assisted spine surgery reduce intraoperative radiation doses? [J].
Gebhard, Florian T. ;
Kraus, Michael D. ;
Schneider, Eugen ;
Liener, Ulrich C. ;
Kinzl, Lothar ;
Arand, Markus .
SPINE, 2006, 31 (17) :2024-2027
[8]  
HERBERT TJ, 1999, J HAND SURG-BRIT, V17, P415
[9]   Navigated ISO-C3D-based drilling of an osteochondral lesion of the talus [J].
Kendoff, D ;
Geerling, J ;
Mahlke, L ;
Citak, M ;
Kfuri, M ;
Hüfner, T ;
Krettek, C .
UNFALLCHIRURG, 2003, 106 (11) :963-967
[10]  
Kendoff Daniel, 2005, Comput Aided Surg, V10, P157, DOI 10.1080/10929080500229868