Characterization and Ex Vivo evaluation of an extracorporeal high-intensity focused ultrasound (HIFU) system

被引:12
|
作者
Zhou, Yufeng [1 ]
Cunitz, Bryan W. [2 ]
Dunmire, Barbrina [2 ]
Wang, Yak-Nam [2 ]
Karl, Steven G. [2 ]
Warren, Cinderella [3 ]
Mitchell, Stuart [2 ]
Hwang, Joo Ha [2 ,3 ]
机构
[1] Northwestern Ploytech Univ, Sch Mech Engn, Xian, Peoples R China
[2] Univ Washington, Dept Med, Div Gastroenterol, Seattle, WA USA
[3] Univ Washington, Appl Phys Lab, Ctr Ind & Med Ultrasound, Seattle, WA 98105 USA
来源
关键词
acoustic nonlinearity; characterization; In-situ acoustic energy; high-intensity focused ultrasound; lesion; CANCER; TEMPERATURE; HYDROPHONE; LESIONS; FIELDS;
D O I
10.1002/acm2.13074
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background High-intensity focused ultrasound (HIFU) has been in clinical use for a variety of solid tumors and cancers. Accurate and reliable calibration is in a great need for clinical applications. An extracorporeal clinical HIFU system applied for the investigational device exemption (IDE) to the Food and Drug Administration (FDA) so that evaluation of its characteristics, performance, and safety was required. Methods The acoustic pressure and power output was characterized by a fiber optic probe and a radiation force balance, respectively, with the electrical power up to 2000 W. An in situ acoustic energy was established as the clinical protocol at the electrical power up to 500 W. Temperature elevation inside the tissue sample was measured by a thermocouple array. Generated lesion volume at different in situ acoustic energies and pathological examination of the lesions was evaluated ex vivo. Results Acoustic pressure mapping showed the insignificant presence of side/grating lobes and pre- or post-focal peaks (<=-12 dB). Although distorted acoustic pressure waveform was found in the free field, the nonlinearity was reduced significantly after the beam propagating through tissue samples (i.e., the second harmonic of -11.8 dB at 500 W). Temperature elevation was <10 degrees C at a distance of 10 mm away from a 20-mm target, which suggests the well-controlled HIFU energy deposition and no damage to the surrounding tissue. An acoustic energy in the range of 750-1250 J resulted in discrete lesions with an interval space of 5 mm between the treatment spots. Histology confirmed that the lesions represented a region of permanently damaged cells by heat fixation, without causing cell lysis by either cavitation or boiling. Conclusions Our characterization and ex vivo evaluation protocol met the IDE requirement. The in-situ acoustic energy model will be used in clinical trials to deliver almost consistent energy to the various targets.
引用
收藏
页码:345 / 359
页数:15
相关论文
共 50 条
  • [41] High-energy shockwaves and extracorporeal high-intensity focused ultrasound
    Madersbacher, S
    Marberger, M
    JOURNAL OF ENDOUROLOGY, 2003, 17 (08) : 667 - 672
  • [42] Development of a High Intensity Focused Ultrasound (HIFU) Hydrophone System
    Schafer, Mark E.
    Gessert, James
    8TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2009, 1113 : 301 - +
  • [43] In Vitro and In Vivo High-Intensity Focused Ultrasound Thrombolysis
    Wright, Cameron
    Hynynen, Kullervo
    Goertz, David
    INVESTIGATIVE RADIOLOGY, 2012, 47 (04) : 217 - 225
  • [44] Development of a High Intensity Focused Ultrasound (HIFU) hydrophone system
    Schafer, ME
    Gessert, J
    Moore, W
    2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 1739 - 1742
  • [45] Extracorporeal ablation of uterine fibroids with high-intensity focused ultrasound - Imaging and histopathologic evaluation
    Ren, Xiao-Long
    Zhou, Xiao-Dong
    Zhang, Jun
    He, Guang-Bin
    Han, Zeng-Hui
    Zheng, Min-Juan
    Li, Li
    Yu, Ming
    Wang, Lei
    JOURNAL OF ULTRASOUND IN MEDICINE, 2007, 26 (02) : 201 - 212
  • [46] Development of a High Intensity Focused Ultrasound (HIFU) hydrophone system
    Schafer, Mark E.
    Gessert, James
    Moore, Wayne
    THERAPEUTIC ULTRASOUND, 2006, 829 : 609 - +
  • [47] High-Intensity Focused Ultrasound (HIFU) Is Not Indicated for Treatment of Primary Bone Sarcomas
    Bielack, Stefan S.
    Marina, Neyssa
    Bernstein, Mark
    CANCER, 2011, 117 (12) : 2822 - 2822
  • [48] High-Intensity Focused Ultrasound (HIFU)-Assisted Hepatic Resection in an Animal Model
    Gandini, Alessandro
    Melodelima, David
    Schenone, Francesco
    N'Djin, Apoutou William
    Chapelon, Jean Yves
    Rivoire, Michel
    ANNALS OF SURGICAL ONCOLOGY, 2012, 19 : S447 - S454
  • [49] Intensification of the impact of high-intensity focused ultrasound (HIFU) with special spatiotemporal modulation
    V. A. Gusev
    O. V. Rudenko
    Acoustical Physics, 2013, 59 : 45 - 50
  • [50] High-Intensity Focused Ultrasound (HIFU)-Assisted Hepatic Resection in an Animal Model
    Alessandro Gandini
    David Melodelima
    Francesco Schenone
    Apoutou William N’Djin
    Jean Yves Chapelon
    Michel Rivoire
    Annals of Surgical Oncology, 2012, 19 : 447 - 454