Automated registration of sequential breath-hold dynamic contrast-enhanced MR images: a comparison of three techniques

被引:16
作者
Rajaraman, Sivaramakrishnan [2 ]
Rodriguez, Jeffrey J. [2 ]
Graff, Christian [3 ]
Altbach, Maria I.
Dragovich, Tomislav [4 ]
Sirlin, Claude B. [5 ]
Korn, Ronald L. [6 ]
Raghunand, Natarajan [1 ,4 ]
机构
[1] Univ Arizona, Arizona Canc Ctr, Dept Radiol, Tucson, AZ 85724 USA
[2] Univ Arizona, Dept Elect & Comp Engn, Tucson, AZ 85721 USA
[3] Univ Arizona, Program Appl Math, Tucson, AZ 85721 USA
[4] Univ Arizona, Ctr Canc, Tucson, AZ 85724 USA
[5] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[6] Scottsdale Med Imaging Ltd, Scottsdale, AZ USA
基金
美国国家卫生研究院;
关键词
Dynamic; Gadolinium; MRI; Mutual information; Non-rigid registration; Elastic registration; Tracer kinetics; NONRIGID REGISTRATION; VOLUME;
D O I
10.1016/j.mri.2011.02.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is increasingly in use as an investigational biomarker of response in cancer clinical studies. Proper registration of images acquired at different time points is essential for deriving diagnostic information from quantitative pharmacokinetic analysis of these data. Motion artifacts in the presence of time-varying intensity due to contrast enhancement make this registration problem challenging. DCE-MRI of chest and abdominal lesions is typically performed during sequential breath-holds, which introduces misregistration due to inconsistent diaphragm positions and also places constraints on temporal resolution vis-a-vis free-breathing. In this work, we have employed a computer-generated DCE-MRI phantom to compare the performance of two published methods, Progressive Principal Component Registration and Pharmacokinetic Model-Driven Registration, with Sequential Elastic Registration (SER) to register adjacent time-sample images using a published general-purpose elastic registration algorithm. In all three methods, a 3D rigid-body registration scheme with a mutual information similarity measure was used as a preprocessing step. The DCE-MRI phantom images were mathematically deformed to simulate misregistration, which was corrected using the three schemes. All three schemes were comparably successful in registering large regions of interest (ROIs) such as muscle, liver, and spleen. SER was superior in retaining tumor volume and shape, and in registering smaller but important ROIs such as tumor core and tumor rim. The performance of SER on clinical DCE-MRI data sets is also presented. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:668 / 682
页数:15
相关论文
共 27 条
  • [1] The visible human project
    Ackerman, MJ
    [J]. PROCEEDINGS OF THE IEEE, 1998, 86 (03) : 504 - 511
  • [2] The effects of renal variation upon measurements of perfusion and leakage volume in breast tumours
    Ahearn, TS
    Staff, RT
    Redpath, TW
    Semple, SIK
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (10) : 2041 - 2051
  • [3] BANERJI A, 2008, P 16 ANN M ISMRM TOR
  • [4] PERFORMANCE OF OPTICAL-FLOW TECHNIQUES
    BARRON, JL
    FLEET, DJ
    BEAUCHEMIN, SS
    [J]. INTERNATIONAL JOURNAL OF COMPUTER VISION, 1994, 12 (01) : 43 - 77
  • [5] Tracer kinetic model-driven registration for dynamic contrast-enhanced MRI time-series data
    Buonaccorsi, Giovanni A.
    O'Connor, James P. B.
    Caunce, Angela
    Roberts, Caleb
    Cheung, Sue
    Watson, Yvonne
    Davies, Karen
    Hope, Lynn
    Jackson, Alan
    Jayson, Gordon C.
    Parker, Geoffrey J. M.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (05) : 1010 - 1019
  • [6] Anisotropic multi-scale fluid registration: evaluation in magnetic resonance breast imaging
    Crum, WR
    Tanner, C
    Hawkes, DJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (21) : 5153 - 5174
  • [7] GRAFF C, 2008, P 16 ANN M ISMRM TOR
  • [8] Hayton P, 1997, Med Image Anal, V1, P207, DOI 10.1016/S1361-8415(97)85011-6
  • [9] HEEGER DJ, 1987, INT J COMPUT VISION, V1, P279, DOI 10.1007/BF00133568
  • [10] HILL A, 2006, 28 ANN INT C IEEE EN, V1, P3049