CFD study of the transient wet gas flow behavior through orifice plate flow meters

被引:8
作者
Weise, Josiane [1 ]
Balino, Jorge L. [2 ]
Paladino, Emilio E. [1 ]
机构
[1] Univ Fed Santa Catarina, Mech Engn Dept, SINMEC Computat Fluid Dynam Lab, BR-88040900 Florianopolis, SC, Brazil
[2] State Univ Sao Paulo, Politech Sch, Dept Mech Engn, Av Prof Mello Moraes 2231,Cidade Univ, BR-05508900 Sao Paulo, SP, Brazil
关键词
Wet gas; Over-reading; Orifice plate meter; Differential pressure fluctuations; Two-fluid model; DIFFERENTIAL PRESSURE; 2-PHASE FLOW; VENTURI;
D O I
10.1016/j.flowmeasinst.2021.102077
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Differential pressure flow meters are widely used in wet gas flow measurement, typically, combined with a method to determine the liquid fraction. An alternative with significant advantages for industry, in term of cost, operation and maintenance, is determining the liquid fraction based on its relation with the statistical parameters of transient differential pressure signal fluctuations. In this way, a single measurement device can provide mass flow rate and liquid fraction simultaneously. For this method to be more feasible in the wet gas flow measurement, it is essential to understand how the differential pressure signal fluctuations and the gas-liquid flow behavior at the restriction are correlated. On this basis, this paper presents a transient 3D Computational Fluid Dynamics (CFD) study of the wet gas flow through an orifice plate, operating under field conditions, using the two-fluid model. Steady-state results, calculated from the time averaging of the transient solution, for the over-reading OR parameter were validated with experimental field data and results obtained by correlations available in the literature, showing very good agreement. The transient results from simulations presented a trend in agreement with experimental data from the literature, showing a positive correlation of the standard deviation of differential pressure signal with liquid fraction upstream of the orifice plate. However, these results should be analyzed qualitatively due to model limitations, mainly related to the interfacial transfer closure in gas-liquid flows with changing phase morphologies. Despite this fact, some important insights regarding the 3D transient flow structure with a practical value were obtained from the model.
引用
收藏
页数:15
相关论文
共 42 条
  • [1] Effect of pipe diameter on the drop size in a horizontal annular gas-liquid flow
    Al-Sarkhi, A
    Hanratty, TJ
    [J]. INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2002, 28 (10) : 1617 - 1629
  • [2] Orifice plate meter field performance: Formulation and validation in multiphase flow conditions
    Campos, S. R. V.
    Balino, J. L.
    Slobodcicov, I.
    Filho, D. F.
    Paz, E. F.
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2014, 58 : 93 - 104
  • [3] RESEARCH NOTE - 2-PHASE FLOW THROUGH SHARP-EDGED ORIFICES
    CHISHOLM, D
    [J]. JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 1977, 19 (03): : 128 - 130
  • [4] DELEEUW R, 1997, N SEA FLOW MEAS WORK
  • [5] MATHEMATICAL-MODELING OF 2-PHASE FLOW
    DREW, DA
    [J]. ANNUAL REVIEW OF FLUID MECHANICS, 1983, 15 : 261 - 291
  • [6] Falcone G., 2001, All Days, DOI [10.2118/71474-MS, DOI 10.2118/71474-MS]
  • [7] A comparison of correlations used for Venturi wet gas metering in oil and gas industry
    Fang Lide
    Tao, Zhang
    Jin Ningde
    [J]. JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2007, 57 (3-4) : 247 - 256
  • [8] STRUCTure-based URANS simulations of thermal mixing in T-junctions
    Feng, Jinyong
    Frahi, Tarek
    Baglietto, Emilio
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2018, 340 : 275 - 299
  • [9] Study on the metering characteristics of a slotted orifice for wet gas flow
    Geng, YF
    Zheng, J
    Shi, TM
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2006, 17 (02) : 123 - 128
  • [10] Two-phase mass flow coefficient of V-Cone throttle device
    He, Deng-Hui
    Bai, Bo-Feng
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2014, 57 : 77 - 85