The Effect of Different Light-curing Units and Tip Distances on the Polymerization Efficiency of Bulk-fill Materials

被引:14
作者
Al Nahedh, H. N. A. [1 ]
Al-Senan, D. F. [2 ]
Alayad, A. S. [1 ]
机构
[1] King Saud Univ, Coll Dent, Dept Restorat Dent Sci, Riyadh, Saudi Arabia
[2] Princess Nourah Univ, Coll Dent, Clin Dent Sci Dept, Riyadh, Saudi Arabia
关键词
DENTAL COMPOSITES; CONVERSION; DEPTH; CURE; MICROHARDNESS; SHRINKAGE; HARDNESS;
D O I
10.2341/20-282-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Problem Statement: In an average class II posterior preparation, the curing light tip is placed at a distance from the restoration surface that far exceeds the 1-mm manufacturer's recommendation. This distance can have potentially detrimental effects on the curing efficiency of the light-curing unit as well as the properties of the resin-based composite restoration, especially at the bottom of the cavity preparation. Purpose: The purpose of this study was to evaluate the effects of various types of light-curing units (LCUs) and the different curing distances on the degree of conversion (DC) and the surface hardness of bulk-fill composite materials. Methods and Materials: A total of 390 specimens of three resin-based composites (RBCs) were fabricated. Two bulk-fill RBCs, including Filtek Bulk Fill Posterior (3M ESPE GmbH, Seefeld, Germany) and Tetric N-Ceram Bulk Fill (Ivoclar Vivadent AG, Schaan, Liechtenstein), as well as a Filtek Z350 XT nano-filled composite (3M ESPE GmbH, Seefeld, Germany), were utilized. In this study, the Vickers microhardness number (VMN) and the DC were evaluated at 2 and 4 mm thicknesses. Polymerization for 20 seconds was performed using two high-power light-curing units, namely the polywave Bluephase G2 light-emitting diode (LED) LCU (Ivoclar Vivadent AG, Schaan, Liechtenstein) and the monowave Elipar Deep Cure S LED LCU (3M Oral Care, St Paul, MN, USA) at 0, 2, and 4 mm distance between the curing tip and the RBC surface. The results were analyzed using the two-way analysis of variance method. Scheffe's post-hoc multiple comparison tests were used to determine significant differences between the materials, the LCU, and the tip distances. Results: The highest DC (70.17) was shown by Filtek Bulk Fill Posterior at a distance of 0 mm, whereas the lowest DC (45.99) was measured for the conventional Filtek Z350 XT at a 4 mm distance. Moreover, higher VMNs were shown by Filtek Bulk Fill and Filtek Z350 composites at 0 mm distance than by the Tetric N-Ceram Bulk Fill composite material when cured with a Bluephase G2 LCU. For all materials, a significant decrease in the DC and mean VMN values was observed at a 4 mm distance in comparison with 0 and 2 mm distances. Conclusions: The DC and VMN values among the studied bulk fill materials were more significantly affected by the material composition and curing protocols. The increased distance from the light tip has a detrimental effect on the mechanical properties of composite resin materials. Significant differences were observed in the curing efficiency of the two LCUs investigated.
引用
收藏
页码:E197 / E210
页数:14
相关论文
共 27 条
[1]  
Bicalho A A, 2014, Oper Dent, V39, pE83, DOI 10.2341/12-442-L
[2]   Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites [J].
Bucuta, Stefan ;
Ilie, Nicoleta .
CLINICAL ORAL INVESTIGATIONS, 2014, 18 (08) :1991-2000
[3]  
Caldas DBM, 2003, OPER DENT, V28, P315
[4]   Impact of the distance of light curing on the degree of conversion and microhardness of a composite resin [J].
Catelan, Anderson ;
Napoleao De Araujo, Larissa Sgarbosa ;
Martins Da Silveira, Bruna Cilene ;
Kawano, Yoshio ;
Bovi Ambrosano, Glaucia Maria ;
Marchi, Giselle Maria ;
Baggio Aguiar, Flavio Henrique .
ACTA ODONTOLOGICA SCANDINAVICA, 2015, 73 (04) :298-301
[5]   Effect of light curing protocol on degree of conversion of composites [J].
Catelan, Anderson ;
Aguiar Jordao Mainardi, Maria Do Carmo ;
Soares, Giulliana Panfiglio ;
De Lima, Adriano Fonseca ;
Bovi Ambrosano, Glaucia Maria ;
Nunes Leite Lima, Debora Alves ;
Marchi, Giselle Maria ;
Baggio Aguiar, Flavio Henrique .
ACTA ODONTOLOGICA SCANDINAVICA, 2014, 72 (08) :898-902
[6]   Developing a more complete understanding of stresses produced in dental composites during polymerization [J].
Ferracane, JL .
DENTAL MATERIALS, 2005, 21 (01) :36-42
[7]  
Garcia-Contreras R, 2015, J ORAL RES, V4, P313
[8]   Influence of increment thickness on light transmission, degree of conversion and micro hardness of bulk fill composites [J].
Garoushi, Sufyan ;
Vallittu, Pekka ;
Shinya, Akikazu ;
Lassila, Lippo .
ODONTOLOGY, 2016, 104 (03) :291-297
[9]   Sufficiency of curing in high-viscosity bulk-fill resin composites with enhanced opacity [J].
Ilie, Nicoleta .
CLINICAL ORAL INVESTIGATIONS, 2019, 23 (02) :747-755
[10]   Effect of light curing units on the polymerization of bulk fill resin-based composites [J].
Kenji Shimokawa, Carlos Alberto ;
Turbino, Miriam Lacalle ;
Giannini, Marcelo ;
Braga, Roberto Ruggiero ;
Price, Richard Bengt .
DENTAL MATERIALS, 2018, 34 (08) :1211-1221