Medical proton dosimetry using radioluminescence from aluminium oxide crystals attached to optical-fiber cables

被引:17
作者
Andersen, C. E. [1 ]
Edmund, J. M.
Medin, J.
Grusell, E.
Jain, M.
Mattsson, S.
机构
[1] Riso Natl Lab, DK-4000 Roskilde, Denmark
[2] Lund Univ, Malmo Univ Hosp, Dept Med Radiat Phys, SE-20502 Malmo, Sweden
[3] Univ Copenhagen Hosp, Finsen Ctr, Dept Radiat Oncol, DK-2100 Copenhagen, Denmark
[4] Univ Uppsala Hosp, Dept Hosp Phys, SE-75185 Uppsala, Sweden
关键词
radiation-induced luminescence; dosimetry; neutron and proton;
D O I
10.1016/j.nima.2007.05.129
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The prime objective of this study is to investigate if radioluminescence (RL) from carbon-doped aluminum oxide (Al2O3:C) crystals potentially can be used for absorbed dose-rate measurements during proton radiotherapy. The RL from two separate (2 mg) Al2O3:C crystals attached to optical-fiber cables were recorded during irradiations in water in a 175 MeV clinical proton beam. The RL response for low-LET protons in the plateau region of the Bragg curve was found to closely resemble that observed for a clinical 6 MV X-ray beam. An identical response was found in the Bragg peak (where the dose-averaged LET is about 4 keV/mu m) for absorbed doses less than 0.3 Gy. For doses in the range of 0.3-3Gy, we observed a significant decrease in luminescence efficiency with LET. At 3 Gy, the luminescence efficiency was about 60% in the Bragg-peak region. The study implies that the RL-signal from Al2O3:C could potentially be suitable for medical proton dosimetry in the 0-0.3 Gy range even without any LET-dependent correction factors. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:466 / 468
页数:3
相关论文
共 5 条
[1]   An algorithm for real-time dosimetry in intensity-modulated radiation therapy using the radioluminescence signal from Al2O3:C [J].
Andersen, C. E. ;
Marckmann, C. J. ;
Aznar, M. C. ;
Botter-Jensen, L. ;
Kjaer-Kristoffersen, F. ;
Medin, J. .
RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) :7-13
[2]   Real-time optical-fibre luminescence dosimetry for radiotherapy:: physical characteristics and applications in photon beams [J].
Aznar, MC ;
Andersen, CE ;
Botter-Jensen, L ;
Bäck, SÅJ ;
Mattsson, S ;
Kjær-Kristoffersen, F ;
Medin, J .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (09) :1655-1669
[3]   General characteristics of the use of silicon diode detectors for clinical dosimetry in proton beams [J].
Grusell, E ;
Medin, J .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09) :2573-2582
[4]  
MEDIN J, 1997, THESIS STOCKHOL U
[5]  
Peto A, 1996, RADIAT PROT DOSIM, V65, P139, DOI 10.1093/oxfordjournals.rpd.a031607