Point-of-care immunotesting: Approaching the analytical performance of central laboratory methods

被引:220
作者
von Lode, P [1 ]
机构
[1] Univ Turku, Dept Biotechnol, FIN-20520 Turku, Finland
关键词
point-of-care testing; immunoassay; unit-dose devices; automation; miniaturization;
D O I
10.1016/j.clinbiochem.2005.03.008
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The use of point-of-care (POC) immunoassays has increased significantly and the menu of analytes continues to expand. Most of the rapid immunoassays are currently based on simple manual assay devices such as the immunochromatographic, agglutination, and immunofiltration assays. Although automated readers have recently been introduced at an increasing pace, the major benefit of these genuinely hand-portable assay devices is that they do not usually necessitate instrumentation but can be performed anywhere. Significant advances in assay and detection technologies have, however, recently facilitated the introduction of truly quantitative, sophisticated immunoassay methods to POC settings as well, with the analytical performance characteristics approaching those of conventional laboratory assays. Furthermore, innovative assay technologies such as those based on immumosensors have been introduced to POC testing (POCT) without ever being employed in clinical laboratories. However, further simplification of the assay procedures and analyzers is still feasible, and strong efforts are directed towards the development of miniaturized and simple, yet sensitive and quantitative, novel assay technologies to keep up with the increasing expectations set on future POC immunotesting. (C) 2005 The Canadian Society of Clinical Chemists. All rights reserved.
引用
收藏
页码:591 / 606
页数:16
相关论文
共 145 条
  • [1] Comparative evaluation of urine-based and other minimally invasive methods for the diagnosis of Helicobacter pylori infection
    Adachi, K
    Kawamura, A
    Ono, M
    Masuzaki, K
    Takashima, T
    Yuki, M
    Fujishiro, H
    Ishihara, S
    Kinoshita, Y
    [J]. JOURNAL OF GASTROENTEROLOGY, 2002, 37 (09) : 703 - 708
  • [2] ENZYME IMMUNOSENSOR .3. AMPEROMETRIC DETERMINATION OF HUMAN CHORIONIC-GONADOTROPIN BY MEMBRANE-BOUND ANTIBODY
    AIZAWA, M
    MORIOKA, A
    SUZUKI, S
    NAGAMURA, Y
    [J]. ANALYTICAL BIOCHEMISTRY, 1979, 94 (01) : 22 - 28
  • [3] ALFTHAN H, 1992, CLIN CHEM, V38, P1981
  • [4] Myocardial infarction redefined -: A consensus Document of the Joint European Society of Cardiology/American College of Cardiology Committee for the Redefinition of Myocardial Infarction
    Alpert, JS
    Antman, E
    Apple, F
    Armstrong, PW
    Bassand, JP
    de Luna, AB
    Beller, G
    Breithardt, G
    Chaitman, BR
    Clemmensen, P
    Falk, E
    Fishbein, MC
    Galvani, M
    Garson, A
    Grines, C
    Hamm, C
    Jaffe, A
    Katus, H
    Kjekshus, J
    Klein, W
    Klootwijk, P
    Lenfant, C
    Levy, D
    Levy, RI
    Luepker, R
    Marcus, F
    Näslund, U
    Ohman, M
    Pahlm, O
    Poole-Wilson, P
    Popp, R
    Alto, P
    Pyörälä, K
    Ravkilde, J
    Rehnquist, N
    Roberts, W
    Roberts, R
    Roelandt, J
    Rydén, L
    Sans, S
    Simoons, ML
    Thygesen, K
    Tunstall-Pedoe, H
    Underwood, R
    Uretsky, BF
    Van de Werf, F
    Voipio-Pulkki, LM
    Wagner, G
    Wallentin, L
    Wijns, W
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (03) : 959 - 969
  • [5] Management of patients with suspected deep vein thrombosis in the Emergency Department: Combining use of a clinical diagnosis model with D-dimer testing
    Anderson, DR
    Wells, PS
    Stiell, I
    MacLeod, B
    Simms, M
    Gray, L
    Robinson, KS
    Bormanis, J
    Mitchell, M
    Lewandowski, B
    Flowerdew, G
    [J]. JOURNAL OF EMERGENCY MEDICINE, 2000, 19 (03) : 225 - 230
  • [6] [Anonymous], POINT CARE J NEAR PA
  • [7] [Anonymous], POINT OF CARE TESTIN
  • [8] Analytical performance of the i-STAT cardiac troponin I assay
    Apple, FS
    Murakami, MM
    Christenson, RH
    Campbell, JL
    Miller, CJ
    Hock, KG
    Scott, MG
    [J]. CLINICA CHIMICA ACTA, 2004, 345 (1-2) : 123 - 127
  • [9] Apple FS, 1999, CLIN CHEM, V45, P199
  • [10] Evaluation of diagnostic reliability of DCA 2000 for rapid and simple monitoring of HbA1c
    Arsie, MP
    Marchioro, L
    Lapolla, A
    Giacchetto, GF
    Bordin, MR
    Rizzotti, P
    Fedele, D
    [J]. ACTA DIABETOLOGICA, 2000, 37 (01) : 1 - 7