In vitro and numerical simulation of blood removal from cerebrospinal fluid: comparison of lumbar drain to Neurapheresis therapy

被引:20
作者
Khani, Mohammadreza [1 ]
Sass, Lucas R. [1 ]
Sharp, M. Keith [2 ]
McCabe, Aaron R. [3 ]
Verbick, Laura M. [3 ]
Lad, Shivanand P. [4 ]
Martin, Bryn A. [1 ]
机构
[1] Univ Idaho, Dept Biol Engn, 875 Perimeter Dr,MS 0904, Moscow, ID 83844 USA
[2] Univ Louisville, Dept Mech Engn, 332 Eastern Pkwy, Louisville, KY 40292 USA
[3] Minnetronix Neuro Inc, 1635 Energy Pk Dr, St Paul, MN 55108 USA
[4] Duke Univ, Sch Med, Dept Neurosurg, 3100 Tower Blvd, Durham, NC 27707 USA
基金
美国国家卫生研究院;
关键词
Computational fluid dynamics; In-vitro model; Subarachnoid hemorrhage; Neurapheresis therapy; Cerebrospinal fluid filtration; Multiphase simulation; ANATOMICAL FINE-STRUCTURE; SUBARACHNOID HEMORRHAGE; CEREBRAL VASOSPASM; CISTERNAL IRRIGATION; SODIUM FLUORESCEIN; FLOW; DYNAMICS; CLEARANCE; PREVENTION; UROKINASE;
D O I
10.1186/s12987-020-00185-5
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background Blood removal from cerebrospinal fluid (CSF) in post-subarachnoid hemorrhage patients may reduce the risk of related secondary brain injury. We formulated a computational fluid dynamics (CFD) model to investigate the impact of a dual-lumen catheter-based CSF filtration system, called Neurapheresis (TM) therapy, on blood removal from CSF compared to lumbar drain. Methods A subject-specific multiphase CFD model of CSF system-wide solute transport was constructed based on MRI measurements. The Neurapheresis catheter geometry was added to the model within the spinal subarachnoid space (SAS). Neurapheresis flow aspiration and return rate was 2.0 and 1.8 mL/min, versus 0.2 mL/min drainage for lumbar drain. Blood was modeled as a bulk fluid phase within CSF with a 10% initial tracer concentration and identical viscosity and density as CSF. Subject-specific oscillatory CSF flow was applied at the model inlet. The dura and spinal cord geometry were considered to be stationary. Spatial-temporal tracer concentration was quantified based on time-average steady-streaming velocities throughout the domain under Neurapheresis therapy and lumbar drain. To help verify CFD results, an optically clear in vitro CSF model was constructed with fluorescein used as a blood surrogate. Quantitative comparison of numerical and in vitro results was performed by linear regression of spatial-temporal tracer concentration over 24-h. Results After 24-h, tracer concentration was reduced to 4.9% under Neurapheresis therapy compared to 6.5% under lumbar drain. Tracer clearance was most rapid between the catheter aspiration and return ports. Neurapheresis therapy was found to have a greater impact on steady-streaming compared to lumbar drain. Steady-streaming in the cranial SAS was 50x smaller than in the spinal SAS for both cases. CFD results were strongly correlated with the in vitro spatial-temporal tracer concentration under Neurapheresis therapy (R-2 = 0.89 with + 2.13% and - 1.93% tracer concentration confidence interval). Conclusion A subject-specific CFD model of CSF system-wide solute transport was used to investigate the impact of Neurapheresis therapy on tracer removal from CSF compared to lumbar drain over a 24-h period. Neurapheresis therapy was found to substantially increase tracer clearance compared to lumbar drain. The multiphase CFD results were verified by in vitro fluorescein tracer experiments.
引用
收藏
页数:17
相关论文
共 73 条
[1]  
[Anonymous], 2018, Extracorporeal Filtration of Subarachnoid Hemorrhage Via Spinal Catheter (PILLAR)
[2]   Relationship between cerebrospinal fluid and blood dynamics in healthy volunteers and patients with communicating hydrocephalus [J].
Balédent, O ;
Gondry-Jouet, C ;
Meyer, ME ;
De Marco, G ;
Le Gars, D ;
Henry-Feugeas, MC ;
Idy-Peretti, I .
INVESTIGATIVE RADIOLOGY, 2004, 39 (01) :45-55
[3]   Prospective Trial of Cerebrospinal Fluid Filtration After Aneurysmal Subarachnoid Hemorrhage via Lumbar Catheter (PILLAR) [J].
Blackburn, Spiros L. ;
Grande, Andrew W. ;
Swisher, Christa B. ;
Hauck, Erik F. ;
Jagadeesan, Bharathi ;
Provencio, J. Javier .
STROKE, 2019, 50 (09) :2558-2561
[4]   Novel Dual Lumen Catheter and Filtration Device for Removal of Subarachnoid hemorrhage: First Case Report [J].
Sekhar, Laligam N. ;
Mooney, Michael ;
Nakaji, Peter ;
Bulsara, Ketan R. .
OPERATIVE NEUROSURGERY, 2019, 16 (05) :E152-E153
[5]   Does Phase-Contrast Imaging through the Cerebral Aqueduct Predict the Outcome of Lumbar CSF Drainage or Shunt Surgery in Patients with Suspected Adult Hydrocephalus? [J].
Blitz, A. M. ;
Shin, J. ;
Baledent, O. ;
Page, G. ;
Bonham, L. W. ;
Herzka, D. A. ;
Moghekar, A. R. ;
Rigamonti, D. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (12) :2224-2230
[6]   CSF pathways: a review [J].
Brodbelt, A. ;
Stoodley, M. .
BRITISH JOURNAL OF NEUROSURGERY, 2007, 21 (05) :510-520
[7]   Diffusion and Aggregation of Sodium Fluorescein in Aqueous Solutions [J].
Casalini, Tommaso ;
Salvalaglio, Matteo ;
Perale, Giuseppe ;
Masi, Maurizio ;
Cavallotti, Carlo .
JOURNAL OF PHYSICAL CHEMISTRY B, 2011, 115 (44) :12896-12904
[8]   Automated segmentation of MR imaging to determine normative central nervous system cerebrospinal fluid volumes in healthy volunteers [J].
Chazen, J. Levi ;
Dyke, Jonathan P. ;
Holt, Robert W. ;
Horky, Laura ;
Pauplis, Rachel A. ;
Hesterman, Jacob Y. ;
Mozley, P. David ;
Verma, Ajay .
CLINICAL IMAGING, 2017, 43 :132-135
[9]  
Coffey CE, 1998, ARCH NEUROL-CHICAGO, V55, P627
[10]   Normal brain development and aging: Quantitative analysis at in vivo MR imaging in healthy volunteers [J].
Courchesne, E ;
Chisum, HJ ;
Townsend, J ;
Cowles, A ;
Covington, J ;
Egaas, B ;
Harwood, M ;
Hinds, S ;
Press, GA .
RADIOLOGY, 2000, 216 (03) :672-682