Automated image acquisition and processing using a new generation of 4K x 4K CCD cameras for cryo electron microscopic studies of macromolecular assemblies

被引:38
作者
Zhang, PJ
Borgnia, MJ
Mooney, P
Shi, D
Pan, M
O'Herron, P
Mao, A
Brogan, D
Milne, JLS
Subramaniam, S [1 ]
机构
[1] NCI, Biochem Lab, NIH, Bethesda, MD 20892 USA
[2] NCI, Cell Biol Labs, NIH, Bethesda, MD 20892 USA
[3] GATAN Inc, Pleasanton, CA USA
关键词
cryo electron microscopy; CCD camera; image processing;
D O I
10.1016/S1047-8477(03)00124-2
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
We have previously reported the development of AutoEM, a software package for semi-automated acquisition of data from a transmission electron microscope. In continuing efforts to improve the speed of structure determination of macromolecular assemblies by electron microscopy, we report here on the performance of a new generation of 4K CCD cameras for use in cryo electron microscopic applications. We demonstrate that at 120 kV, and at a nominal magnification of 67 000 x, power spectra and signal-to-noise ratios for the new 4K CCD camera are comparable to values obtained for film images scanned using a Zeiss scanner to resolutions as high as similar to1/6.5 Angstrom(-1). The specimen area imaged for each exposure on the 4K CCD is about one-third of the area that can be recorded with a similar exposure on film. The CCD camera also serves the purpose of recording images at low magnification from the center of the hole to measure the thickness of vitrified ice in the hole. The performance of the camera is satisfactory under the low-dose conditions used in cryo electron microscopy, as demonstrated here by the determination of a three-dimensional map at 15 Angstrom for the catalytic core of the 1.8 MDa Bacillus stearothermophilus icosahedral pyruvate dehydrogenase complex, and its comparison with the previously reported atomic model for this complex obtained by X-ray crystallography. Published by Elsevier Inc.
引用
收藏
页码:135 / 144
页数:10
相关论文
共 32 条
[1]   The catalytic domain of dihydrolipoyl acetyltransferase from the pyruvate dehydrogenase multienzyme complex of Bacillus stearothermophilus - Expression, purification and reversible denaturation [J].
Allen, MD ;
Perham, RN .
FEBS LETTERS, 1997, 413 (02) :339-343
[2]  
[Anonymous], 1996, 3 DIMENSIONAL ELECT
[3]   Leginon: An automated system for acquisition of images from vitreous ice specimens [J].
Carragher, B ;
Kisseberth, N ;
Kriegman, D ;
Milligan, RA ;
Potter, CS ;
Pulokas, J ;
Reilein, A .
JOURNAL OF STRUCTURAL BIOLOGY, 2000, 132 (01) :33-45
[4]   Virus maturation involving large subunit rotations and local refolding [J].
Conway, JF ;
Wikoff, WR ;
Cheng, N ;
Duda, RL ;
Hendrix, RW ;
Johnson, JE ;
Steven, AC .
SCIENCE, 2001, 292 (5517) :744-748
[5]   Development and performance of a fast fibre-plate coupled CCD camera at medium energy and image processing system for electron holography [J].
Daberkow, I ;
Herrmann, KH ;
Liu, L ;
Rau, WD ;
Tietz, H .
ULTRAMICROSCOPY, 1996, 64 (1-4) :35-48
[6]   PERFORMANCE OF ELECTRON IMAGE CONVERTERS WITH YAG SINGLE-CRYSTAL SCREEN AND CCD SENSOR [J].
DABERKOW, I ;
HERRMANN, KH ;
LIU, LB ;
RAU, WD .
ULTRAMICROSCOPY, 1991, 38 (3-4) :215-223
[7]   3-DIMENSIONAL STRUCTURE OF LIPID VESICLES EMBEDDED IN VITREOUS ICE AND INVESTIGATED BY AUTOMATED ELECTRON TOMOGRAPHY [J].
DIERKSEN, K ;
TYPKE, D ;
HEGERL, R ;
WALZ, J ;
SACKMANN, E ;
BAUMEISTER, W .
BIOPHYSICAL JOURNAL, 1995, 68 (04) :1416-1422
[8]   Performance of a 2k CCD camera designed for electron crystallography at 400 kV [J].
Downing, KH ;
Hendrickson, FM .
ULTRAMICROSCOPY, 1999, 75 (04) :215-233
[9]  
DOWNING KH, 2000, P 58 ANN M MICR SOC, P734
[10]   Evaluation of gadolinium oxy-sulphide (P43) phosphor used in CCD detectors for electron microscopy [J].
Faruqi, AR ;
Tyrell, GC .
ULTRAMICROSCOPY, 1999, 76 (1-2) :69-75