Current status and future developments of LC-MS/MS in clinical chemistry for quantification of biogenic amines

被引:54
作者
de Jong, Wilhelmina H. A. [1 ]
de Vries, Elisabeth G. E. [2 ]
Kema, Ido P. [1 ]
机构
[1] Univ Groningen, Dept Lab Med, Univ Med Ctr Groningen, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen, Dept Med Oncol, Univ Med Ctr Groningen, NL-9700 RB Groningen, Netherlands
关键词
TANDEM-MASS-SPECTROMETRY; SOLID-PHASE EXTRACTION; PERFORMANCE LIQUID-CHROMATOGRAPHY; PLASMA-FREE METANEPHRINES; STABLE-ISOTOPE DILUTION; CARCINOID-TUMORS; BIOCHEMICAL-DIAGNOSIS; HOMOVANILLIC-ACID; TRACE-ANALYSIS; CATECHOLAMINE METABOLITES;
D O I
10.1016/j.clinbiochem.2010.07.006
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is rapidly gaining ground in special clinical chemistry laboratories. It significantly increases the analytic potential in clinical chemistry, especially in the field of low molecular weight biomarker analysis. This review overviews current LC-MS/MS methods used for the quantification of biogenic amines and their metabolites. New possibilities offered by this technique are illustrated by recently developed assays for biogenic amines. Major shortcomings of conventional chromatographic techniques, such as labor-intensive sample preparation, long analysis times and often the relatively low specificity, are circumvented by using LC-MS/MS. In addition, LC-MS/MS has broad analyte compatibility and high analytical performance. In the last 5 years introduction of LC-MS/MS in routine diagnostics has resulted in improved assays for diagnosis and follow-up of neuroendocrine tumors characterized by the secretion of biogenic amines. Due to their labile nature and low concentration ranges biogenic amines require extensive and careful sample preparation. Introduction of new sophisticated techniques such as selective sorbents adsorption is evolving. This enables not only more specific analyte selection, but also automation of the complicated clean-up procedure. Automated sample clean-up can be directly coupled to LC-MS/MS, which facilitates reproducible and efficient handling of the growing number of samples to be analyzed in laboratories.. (C) 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:95 / 103
页数:9
相关论文
共 95 条
[1]   Poly(ethylene glycol)-Based Stable Isotope Labeling Reagents for the Quantitative Analysis of Low Molecular Weight Metabolites by LC-MS [J].
Abello, Nicolas ;
Geurink, Paul P. ;
van der Toorn, Marco ;
van Oosterhout, Antoon J. M. ;
Lugtenburg, Johan ;
van der Marel, Gijs A. ;
Kerstjens, Huib A. M. ;
Postma, Dirkje S. ;
Overkleeft, Hermen S. ;
Bischoff, Rainer .
ANALYTICAL CHEMISTRY, 2008, 80 (23) :9171-9180
[2]   Quantitation of tryptophan, kynurenine and kynurenic acid in human plasma by capillary liquid chromatography-electrospray ionization tandem mass spectrometry [J].
Amirkhani, A ;
Heldin, E ;
Markides, KE ;
Bergquist, J .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 780 (02) :381-387
[3]   Ion suppression in mass spectrometry [J].
Annesley, TM .
CLINICAL CHEMISTRY, 2003, 49 (07) :1041-1044
[4]   Catecholamines and methods for their identification and quantitation in biological tissues and fluids [J].
Bergquist, J ;
Sciubisz, A ;
Kaczor, A ;
Silberring, J .
JOURNAL OF NEUROSCIENCE METHODS, 2002, 113 (01) :1-13
[5]  
BOOMSMA F, 1993, CLIN CHEM, V39, P2503
[6]  
Boos KS, 1997, LC GC-MAG SEP SCI, V15, P602
[7]  
Chan ECY, 2000, RAPID COMMUN MASS SP, V14, P1959, DOI 10.1002/1097-0231(20001115)14:21<1959::AID-RCM117>3.0.CO
[8]  
2-T
[9]   Quantification of testosterone and epitestosterone in biological samples by capillary electrophoresis with immunoaffinity extraction [J].
Chen, Hong-Xu ;
Deng, Qin-Pei ;
Zhang, Li-Wei ;
Zhang, Xin-Xiang .
TALANTA, 2009, 78 (02) :464-470
[10]   Measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in human serum using liquid chromatography-tandem mass spectrometry and its comparison to a radioimmunoassay method [J].
Chen, Huiping ;
McCoy, Leslie F. ;
Schleicher, Rosemary L. ;
Pfeiffer, Christine M. .
CLINICA CHIMICA ACTA, 2008, 391 (1-2) :6-12