Proximity focusing RICH with flat panel PMT as photon detector and aerogel as radiator

被引:15
作者
Krizan, P [1 ]
Adachi, I
Fratina, S
Fukushima, S
Gorisek, A
Iijima, T
Kawai, H
Konishi, H
Korpar, S
Kozakai, Y
Matsumoto, T
Mazuka, Y
Nishida, S
Ogawa, S
Ohtake, S
Pestotnik, R
Saitoh, S
Seki, T
Sumiyoshi, T
Uchida, Y
Unno, Y
Yamamoto, S
机构
[1] Univ Ljubljana, Fac Math & Phys, Ljubljana, Slovenia
[2] J Stefan Inst, Ljubljana, Slovenia
[3] Chiba Univ, Chiba, Japan
[4] Nagoya Univ, Nagoya, Aichi, Japan
[5] Univ Maribor, Fac Chem & Chem Engn, SLO-2000 Maribor, Slovenia
[6] Tokyo Metropolitan Univ, Tokyo 158, Japan
[7] Toho Univ, Funabashi, Chiba 274, Japan
关键词
ring imaging Cherenkov counter; proximity focusing; aerogel; H8500 flat panel PMT; particle identification; belle;
D O I
10.1016/j.nima.2005.08.007
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Using aerogel as radiator and 64-channel flat panel multi-anode PMTs (Hamamatsu H8500) for photon detection, a proximity focusing Cherenkov ring imaging detector has been constructed and tested in the KEK pi 2 beam. The single photon resolution obtained in the tests (typically around 14 mrad) is well approximated by estimates of contributions from pixel size and emission point uncertainty. The number of detected photons per Cherenkov ring, typically about 6 for a 2 cm thick aerogel radiator tile, is in good agreement with estimates based on aerogel and detector characteristics. The detector allows a very efficient separation of kaons and pions at 4 GeV/c. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:58 / 63
页数:6
相关论文
共 10 条
  • [1] ABE K, 200404 KEK
  • [2] Tests of a proximity focusing RICH with aerogel as radiator
    Adachi, I
    Bizjak, I
    Gorisek, A
    Iijima, T
    Iwamoto, M
    Korpar, S
    Krizan, P
    Pestotnik, R
    Staric, M
    Stanovnik, A
    Sumiyoshi, T
    Suzuki, K
    Tabata, T
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (04) : 1142 - 1146
  • [3] STUDY OF A THRESHOLD CHERENKOV COUNTER BASED ON SILICA AEROGELS WITH LOW REFRACTIVE-INDEXES
    ADACHI, I
    SUMIYOSHI, T
    HAYASHI, K
    IIDA, N
    ENOMOTO, R
    TSUKADA, K
    SUDA, R
    MATSUMOTO, S
    NATORI, K
    YOKOYAMA, M
    YOKOGAWA, H
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 355 (2-3) : 390 - 398
  • [4] The HERMES dual-radiator ring imaging Cherenkov detector
    Akopov, N
    Aschenauer, EC
    Bailey, K
    Bernreuther, K
    Bianchi, N
    Capitani, GP
    Carter, P
    Cisbani, E
    De Leo, R
    De Sanctis, E
    De Schepper, D
    Djordjadze, V
    Filippone, BW
    Frullani, S
    Garibaldi, F
    Hansen, JO
    Hommez, B
    Iodice, M
    Jackson, HE
    Jung, P
    Kaiser, R
    Kanesaka, J
    Kowalczyk, R
    Lagamba, L
    Maas, A
    Muccifora, V
    Nappi, E
    Negodaeva, K
    Nowak, WD
    O'Connor, T
    O'Neill, TG
    Potterveld, DH
    Ryckbosch, D
    Sakemi, Y
    Sato, F
    Schwind, A
    Shibata, TA
    Suetsugu, K
    Thomas, E
    Tytgat, M
    Urciuoli, GM
    Van de Kerckhove, K
    Van de Vyver, R
    Yoneyama, S
    Zohrabian, H
    Zhang, LF
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 479 (2-3) : 511 - 530
  • [5] SILICA AEROGELS USED AS CHERENKOV RADIATORS
    CANTIN, M
    CASSE, M
    KOCH, L
    JOUAN, R
    MESTREAU, P
    ROUSSEL, D
    BONNIN, F
    MOUTEL, J
    TEICHNER, SJ
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1974, 118 (01): : 177 - 182
  • [6] Aerogel Cherenkov counter for the BELLE detector
    Iijima, T
    Adachi, I
    Enomoto, R
    Suda, R
    Sumiyoshi, T
    Leonidopoulos, C
    Marlow, DR
    Prebys, E
    Kawai, H
    Kurihara, E
    Nanao, M
    Suzuki, K
    Unno, Y
    Ogawa, S
    Murakami, A
    Khan, MHR
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 453 (1-2) : 321 - 325
  • [7] Single-channel prototype of a CMOS SVD preamplifier for the B-factory experiment, BELLE
    Ikeda, H
    Saitoh, Y
    Yamanaka, J
    Kitta, T
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 372 (1-2) : 125 - 134
  • [8] KORPAR S, 2001, IEEE NSS 2001 C SAN
  • [9] Studies of proximity focusing RICH with an aerogel radiator using flat-panel multi-anode PMTs (Hamamatsu H8500)
    Matsumoto, T
    Korpar, S
    Adachi, I
    Fratina, S
    Iijima, T
    Ishibashi, R
    Kawai, H
    Krizan, P
    Ogawa, S
    Pestotnik, R
    Saitoh, S
    Seki, T
    Sumiyoshi, T
    Suzuki, K
    Tabata, T
    Uchida, Y
    Unno, Y
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 521 (2-3) : 367 - 377
  • [10] Silica aerogels in high energy physics
    Sumiyoshi, T
    Adachi, I
    Enomoto, R
    Iijima, T
    Suda, R
    Yokoyama, M
    Yokogawa, H
    [J]. JOURNAL OF NON-CRYSTALLINE SOLIDS, 1998, 225 (01) : 369 - 374