Long-term Excretion of Gadolinium-based Contrast Agents: Linear versus Macrocyclic Agents in an Experimental Rat Model

被引:94
作者
Jost, Gregor [1 ]
Frenzel, Thomas [1 ]
Boyken, Janina [2 ]
Lohrke, Jessica [1 ]
Nischwitz, Volker [3 ]
Pietsch, Hubertus [1 ]
机构
[1] Bayer, Dept MR & CT Contrast Media Res, Muellerstr 178, D-13353 Berlin, Germany
[2] Charite, Inst Physiol, Berlin, Germany
[3] Forschungszentrum Juelich, Julich, Germany
关键词
T1-WEIGHTED MR-IMAGES; HIGH SIGNAL INTENSITY; DENTATE NUCLEUS; MAGNETIC-RESONANCE; GLOBUS-PALLIDUS; HEALTHY RATS; BRAIN; ADMINISTRATIONS; RETENTION; INCREASE;
D O I
10.1148/radiol.2018180135
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the long-term course of MRI signal intensity (SI) changes and the presence of gadolinium in the rat brain during a 1-year period after multiple administrations of gadolinium-based contrast agents (GBCAs). Materials and Methods: Rats received a linear GBCA (gadodiamide, gadopentetate dimeglumine, gadobenate dimeglumine), a macrocyclic GBCA (gadobutrol, gadoterate meglumine, gadoteridol), or saline. Animals received eight injections over 2 weeks (1.8 mmol/kg per injection). Brain MRI and gadolinium measurements were performed with inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS 5, 26, and 52 weeks after administration. Results: Animals that received linear GBCAs showed higher deep cerebellar nuclei (DCN)-to-brainstem SI ratios compared with the saline group (P<.001 at all time points). After 1 year, mean gadolinium concentrations in the cerebellum were 3.38 nmol/g (gadodiamide), 2.13 nmol/g (gadopentetate dimeglumine), and 1.91 nmol/g (gadobenate dimeglumine). For linear agents, laser ablation ICP-MS revealed gadolinium depositions in the cerebellar nuclei. For macrocyclic GBCAs, the DCN-to-brainstem SI ratios did not significantly differ from those in the saline group (P>.42) and the cerebellar gadolinium concentrations decreased between weeks 5 and 52, reaching 0.08 nmol/g (gadobutrol), 0.04 nmol/g (gadoterate meglumine), and 0.07 nmol/g (gadoteridol). The respective laser ablation ICP-MS analysis showed no gadolinium depositions. Conclusion: Increased signal intensity in the deep cerebellar nuclei of rats persists for at least 1 year after administration of linear gadolinium-based contrast agents (GBCAs), in line with persistent brain gadolinium concentrations with no elimination after the initial 5-week period. The animals that received macrocyclic GBCAs showed an ongoing elimination of gadolinium from the brain during the entire observation period. (c) RSNA, 2018
引用
收藏
页码:340 / 348
页数:9
相关论文
共 35 条
[1]   What Evidence Is There That Gadobutrol Causes Increasing Signal Intensity within the Dentate Nucleus and Globus Pallidus on Unenhanced T1W MRI in Patients with RRMS? [J].
Agris, Jacob ;
Pietsch, Hubertus ;
Balzer, Thomas .
EUROPEAN RADIOLOGY, 2016, 26 (03) :816-817
[2]  
[Anonymous], GUID IND EST MAX SAF
[3]   Signal Enhancement of the Dentate Nucleus at Unenhanced MR Imaging after Very High Cumulative Doses of the Macrocyclic Gadolinium-based Contrast Agent Gadobutrol: An Observational Study [J].
Bjornerud, Atle ;
Vatnehol, Svein Are Sirirud ;
Larsson, Christopher ;
Due-Tonnessen, Paulina ;
Hol, Per Kristian ;
Groote, Inge Rasmus .
RADIOLOGY, 2017, 285 (02) :434-444
[4]   Dentate Update: Imaging Features of Entities That Affect the Dentate Nucleus [J].
Bond, K. M. ;
Brinjikji, W. ;
Eckel, L. J. ;
Kallmes, D. F. ;
McDonald, R. J. ;
Carr, C. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (08) :1467-1474
[5]   Gadolinium Accumulation in the Deep Cerebellar Nuclei and Globus Pallidus After Exposure to Linear but Not Macrocyclic Gadolinium-Based Contrast Agents in a Retrospective Pig Study With High Similarity to Clinical Conditions [J].
Boyken, Janina ;
Frenzel, Thomas ;
Lohrke, Jessica ;
Jost, Gregor ;
Pietsch, Hubertus .
INVESTIGATIVE RADIOLOGY, 2018, 53 (05) :278-285
[6]   Differences in gadolinium retention after repeated injections of macrocyclic MR contrast agents to rats [J].
Bussi, Simona ;
Coppo, Alessandra ;
Botteron, Catherine ;
Fraimbault, Valerie ;
Fanizzi, Antonello ;
De Laurentiis, Elisa ;
Colombo Serra, Sonia ;
Kirchin, Miles A. ;
Tedoldi, Fabio ;
Maisano, Federico .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (03) :746-752
[7]   Signal Change in the Dentate Nucleus on T1-Weighted MR Images After Multiple Administrations of Gadopentetate Dimeglumine Versus Gadobutrol [J].
Cao, Yan ;
Huang, Daisy Q. ;
Shih, George ;
Prince, Martin R. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (02) :414-419
[8]   Progressive Increase of T1 Signal Intensity of the Dentate Nucleus on Unenhanced Magnetic Resonance Images Is Associated With Cumulative Doses of Intravenously Administered Gadodiamide in Patients With Normal Renal Function, Suggesting Dechelation [J].
Errante, Yuri ;
Cirimele, Vincenzo ;
Mallio, Carlo Augusto ;
Di Lazzaro, Vincenzo ;
Zobel, Bruno Beomonte ;
Quattrocchi, Carlo Cosimo .
INVESTIGATIVE RADIOLOGY, 2014, 49 (10) :685-690
[9]  
Espagnet MCR, 2017, PEDIATR RADIOL, V47, P1345, DOI 10.1007/s00247-017-3874-1
[10]   Quantification and Assessment of the Chemical Form of Residual Gadolinium in the Brain After Repeated Administration of Gadolinium-Based Contrast Agents Comparative Study in Rats [J].
Frenzel, Thomas ;
Apte, Chirag ;
Jost, Gregor ;
Schockel, Laura ;
Lohrke, Jessica ;
Pietsch, Hubertus .
INVESTIGATIVE RADIOLOGY, 2017, 52 (07) :396-404