Glucose in human serum determined by capillary electrophoresis with glucose micro-biosensor

被引:21
|
作者
Wang, Xiaolei [1 ,2 ]
Zhang, Yan [1 ]
Cheng, Cuicui [1 ]
Dong, Ranran [1 ]
Hao, Jingcheng [3 ]
机构
[1] Shandong Normal Univ, Coll Chem Chem Engn & Mat Sci, Engn Res Ctr Pesticide & Med Intermediate Clean P, Key Lab Mol & Nano Probes,Minist Educ,Shandong Pr, Jinan 250014, Peoples R China
[2] Shandong Univ, Inst Crystal Mat, Jinan 250100, Peoples R China
[3] Shandong Univ, Minist Educ, Key Lab Colloid & Interface Chem, Jinan 250100, Peoples R China
关键词
ELECTROCHEMICAL DETECTION; GOLD NANOPARTICLE; REDOX ENZYMES; OXIDASE; ELECTRODE; SENSOR; FILM; IMMOBILIZATION; PRECOLUMN; BILAYER;
D O I
10.1039/c0an00348d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glucose micro-biosensor was employed as detector in capillary electrophoresis (CE) for determining the concentration of glucose in human serum. The micro-biosensor was based on the immobilization of the SWNTs-glucose oxidase-chitosan biocomposite at a platinized Au electrode by electrodeposition. The influencing factors including separation voltage, detection potential, pH value, and the concentration of the buffer were studied. Suitable conditions were obtained for the determination of glucose: running buffer, 25 mM PBS (pH 8.0); separation field strength, 250 V cm(-1); detection potential, 0.80 V vs. saturated calomel electrode. Under optimized detection conditions, glucose responded linearly from the range of 5 mM to 1 mM with a correlation coefficient of 0.9986 for the injection voltage of 5.0 kV and injection time of 10 s. The concentration limit of detection of the method was 1 mM (S/N 3). The micro-biosensor exhibited good stability and durability in the analytical procedures. The relative standard deviation of the migration time and peak current were 1.7% and 2.6%, respectively. Glucose in human serum from two healthy individuals and two diabetics was successfully determined, giving a good prospect for a new clinical diagnostic instrument.
引用
收藏
页码:1753 / 1759
页数:7
相关论文
共 50 条
  • [41] Capillary glucose meters cannot substitute serum glucose measurement to determine the cerebrospinal fluid to blood glucose ratio: A prospective observational study
    Asmolov, Romain
    Rousseau, Geoffroy
    Grammatico-Guillon, Leslie
    Guillon, Antoine
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2017, 34 (12) : 854 - 856
  • [42] Simultaneous Determination of Levodopa and Methyldopa in Human Serum by Capillary Electrophoresis
    Wang Chun
    Wang Zhi
    Han Dandan
    Hu Yanxue
    Zhao Jin
    Yang Xiumin
    Song Shuangju
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2006, 24 (04) : 389 - 391
  • [43] Microchip-based capillary electrophoresis of human serum proteins
    Colyer, CL
    Mangru, SD
    Harrison, DJ
    JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) : 271 - 276
  • [44] Measurement of glucose concentrations in human blood sera with a bacterial biosensor
    Reshetilov, AN
    Ilyasov, PV
    Donova, MV
    Dovbnya, DV
    Boronin, AM
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 1995, 120 (08) : 861 - 864
  • [45] Microchip capillary electrophoresis with electrochemical detector for precolumn enzymatic analysis of glucose, creatinine, uric acid and ascorbic acid in urine and serum
    Lee, HL
    Chen, SC
    TALANTA, 2004, 64 (03) : 750 - 757
  • [46] Ultrasensitive analysis of glucose in serum by capillary electrophoresis with LIF detection in combination with signal amplification strategies and on-column enzymatic assay
    Guan, Yueqing
    Zhou, Guobin
    ELECTROPHORESIS, 2016, 37 (5-6) : 834 - 840
  • [47] GLUCOSE CONTENT IN CEREBROSPINAL-FLUID - COMPARISON WITH GLUCOSE LEVELS IN SERUM AS DETERMINED BY COPPER REDUCTION AND HEXOKINASE METHODS
    GREENAWA.KA
    SPEICHER, CE
    EVERS, W
    HENRY, JB
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1973, 59 (04) : 518 - 520
  • [48] On-chip micro-biosensor for the detection of human CD4+ cells based on AC impedance and optical analysis
    Mishra, NN
    Retterer, S
    Zieziulewicz, TJ
    Isaacson, M
    Szarowski, D
    Mousseau, DE
    Lawrence, DA
    Turner, JN
    BIOSENSORS & BIOELECTRONICS, 2005, 21 (05): : 696 - 704
  • [49] UNICELLULAR HISTOGENESIS OF UTERINE LEIOMYOMAS AS DETERMINED BY ELECTROPHORESIS OF GLUCOSE-6-PHOSPHATE DEHYDROGENASE
    TOWNSEND, DE
    SPARKES, RS
    BALUDA, MC
    MCCLELLAND, G
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1970, 107 (08) : 1168 - +
  • [50] Determination of human blood glucose levels using microchip electrophoresis
    Maeda, Eilki
    Kataoka, Masatoshi
    Hino, Mami
    Kajimoto, Kazuaki
    Kaji, Noritada
    Tokeshi, Manabu
    Kido, Jun-Ichi
    Shinohara, Yasuo
    Baba, Yoshinobu
    ELECTROPHORESIS, 2007, 28 (16) : 2927 - 2933