Glucose in human serum determined by capillary electrophoresis with glucose micro-biosensor

被引:21
|
作者
Wang, Xiaolei [1 ,2 ]
Zhang, Yan [1 ]
Cheng, Cuicui [1 ]
Dong, Ranran [1 ]
Hao, Jingcheng [3 ]
机构
[1] Shandong Normal Univ, Coll Chem Chem Engn & Mat Sci, Engn Res Ctr Pesticide & Med Intermediate Clean P, Key Lab Mol & Nano Probes,Minist Educ,Shandong Pr, Jinan 250014, Peoples R China
[2] Shandong Univ, Inst Crystal Mat, Jinan 250100, Peoples R China
[3] Shandong Univ, Minist Educ, Key Lab Colloid & Interface Chem, Jinan 250100, Peoples R China
关键词
ELECTROCHEMICAL DETECTION; GOLD NANOPARTICLE; REDOX ENZYMES; OXIDASE; ELECTRODE; SENSOR; FILM; IMMOBILIZATION; PRECOLUMN; BILAYER;
D O I
10.1039/c0an00348d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glucose micro-biosensor was employed as detector in capillary electrophoresis (CE) for determining the concentration of glucose in human serum. The micro-biosensor was based on the immobilization of the SWNTs-glucose oxidase-chitosan biocomposite at a platinized Au electrode by electrodeposition. The influencing factors including separation voltage, detection potential, pH value, and the concentration of the buffer were studied. Suitable conditions were obtained for the determination of glucose: running buffer, 25 mM PBS (pH 8.0); separation field strength, 250 V cm(-1); detection potential, 0.80 V vs. saturated calomel electrode. Under optimized detection conditions, glucose responded linearly from the range of 5 mM to 1 mM with a correlation coefficient of 0.9986 for the injection voltage of 5.0 kV and injection time of 10 s. The concentration limit of detection of the method was 1 mM (S/N 3). The micro-biosensor exhibited good stability and durability in the analytical procedures. The relative standard deviation of the migration time and peak current were 1.7% and 2.6%, respectively. Glucose in human serum from two healthy individuals and two diabetics was successfully determined, giving a good prospect for a new clinical diagnostic instrument.
引用
收藏
页码:1753 / 1759
页数:7
相关论文
共 50 条
  • [31] Direct analysis of bromide in human serum by capillary electrophoresis
    Pascali, Jennifer P.
    Trettene, Maristella
    Bortolotti, Federica
    de Paoli, Giorgia
    Gottardo, Rossella
    Tagliaro, Franco
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 839 (1-2): : 2 - 5
  • [32] Micro-Sized glucose biosensor based on composite pH sensor
    Bal Altuntas, Derya
    Tavukcuoglu, Ozlem
    PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI, 2018, 24 (07): : 1355 - 1359
  • [33] Behaviour of micro-fabricated composite membrane as amperometric glucose biosensor
    Pereira, CM
    Oliveira, JM
    Silva, F
    NANOSTRUCTURED MATERIALS AND COATINGS FOR BIOMEDICAL AND SENSOR APPLICATIONS, 2003, 102 : 365 - 370
  • [34] COULOMETRIC DETERMINATION OF GLUCOSE IN HUMAN SERUM
    SIMON, RK
    CHRISTIAN, GD
    PURDY, WC
    CLINICAL CHEMISTRY, 1968, 14 (05) : 463 - +
  • [35] EFFECT OF TURBIDITY ON SERUM GLUCOSE RESULTS AS DETERMINED ON THE DUPONT ACA
    MERRILL, C
    STATLAND, BE
    CLINICAL CHEMISTRY, 1981, 27 (06) : 1051 - 1051
  • [36] Assays for serum cholinesterase activity by capillary electrophoresis and an amperometric flow injection choline biosensor
    Hsieh, Bo-Chuan
    Hsiao, Hsien-Yi
    Cheng, Tzong-Jih
    Chen, Richie L. C.
    ANALYTICA CHIMICA ACTA, 2008, 623 (02) : 157 - 162
  • [37] Successive detection of glucose and bio-copper in human serum based on a multiplex biosensor of gold nanorods
    Chen, Shenna
    Zhao, Qian
    Zhang, Lingyang
    Xia, Xiaodong
    Huang, Haowen
    ANALYTICAL METHODS, 2015, 7 (03) : 1018 - 1025
  • [38] Expanding the capillary electrophoresis-based glucose unit database of the GUcal app
    Jarvas, Gabor
    Szigeti, Marton
    Campbell, Matthew P.
    Guttman, Andras
    GLYCOBIOLOGY, 2020, 30 (06) : 362 - 364
  • [39] N-GLYCAN GLUCOSE UNIT (GU) DATABASE FOR CAPILLARY GEL ELECTROPHORESIS
    Kerekgyarto, Marta
    Guttman, Andras
    CECE 2014: 11TH INTERNATIONAL INTERDISCIPLINARY MEETING ON BIOANALYSIS, 2014, : 275 - 277
  • [40] Determination of salicylic acid in human serum with capillary zone electrophoresis
    Goto, Y
    Makino, K
    Kataoka, Y
    Shuto, H
    Oishi, R
    JOURNAL OF CHROMATOGRAPHY B, 1998, 706 (02): : 329 - 335