Glucose in human serum determined by capillary electrophoresis with glucose micro-biosensor

被引:21
|
作者
Wang, Xiaolei [1 ,2 ]
Zhang, Yan [1 ]
Cheng, Cuicui [1 ]
Dong, Ranran [1 ]
Hao, Jingcheng [3 ]
机构
[1] Shandong Normal Univ, Coll Chem Chem Engn & Mat Sci, Engn Res Ctr Pesticide & Med Intermediate Clean P, Key Lab Mol & Nano Probes,Minist Educ,Shandong Pr, Jinan 250014, Peoples R China
[2] Shandong Univ, Inst Crystal Mat, Jinan 250100, Peoples R China
[3] Shandong Univ, Minist Educ, Key Lab Colloid & Interface Chem, Jinan 250100, Peoples R China
关键词
ELECTROCHEMICAL DETECTION; GOLD NANOPARTICLE; REDOX ENZYMES; OXIDASE; ELECTRODE; SENSOR; FILM; IMMOBILIZATION; PRECOLUMN; BILAYER;
D O I
10.1039/c0an00348d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glucose micro-biosensor was employed as detector in capillary electrophoresis (CE) for determining the concentration of glucose in human serum. The micro-biosensor was based on the immobilization of the SWNTs-glucose oxidase-chitosan biocomposite at a platinized Au electrode by electrodeposition. The influencing factors including separation voltage, detection potential, pH value, and the concentration of the buffer were studied. Suitable conditions were obtained for the determination of glucose: running buffer, 25 mM PBS (pH 8.0); separation field strength, 250 V cm(-1); detection potential, 0.80 V vs. saturated calomel electrode. Under optimized detection conditions, glucose responded linearly from the range of 5 mM to 1 mM with a correlation coefficient of 0.9986 for the injection voltage of 5.0 kV and injection time of 10 s. The concentration limit of detection of the method was 1 mM (S/N 3). The micro-biosensor exhibited good stability and durability in the analytical procedures. The relative standard deviation of the migration time and peak current were 1.7% and 2.6%, respectively. Glucose in human serum from two healthy individuals and two diabetics was successfully determined, giving a good prospect for a new clinical diagnostic instrument.
引用
收藏
页码:1753 / 1759
页数:7
相关论文
共 50 条
  • [21] Activation of nylon net and its application to a biosensor for determination of glucose in human serum
    Nan, Caifeng
    Zhang, Yan
    Zhang, Guomei
    Dong, Chuan
    Shuang, Shaomin
    Choi, Martin M. F.
    ENZYME AND MICROBIAL TECHNOLOGY, 2009, 44 (05) : 249 - 253
  • [22] Nonimmobilized Biomaterial Capillary Electrophoresis for Screening Drugs Targeting Human Glucose Transporter 1
    Wu, Ruijun
    Zhu, Kai
    Zhang, Xiaodan
    Zhang, Sufang
    Liu, Yanmeng
    Ren, Jinyu
    Li, Cong
    Ye, Min
    Lin, Xiaomei
    ANALYTICAL CHEMISTRY, 2017, 89 (23) : 12951 - 12959
  • [23] Studies on the interaction of photosensitizers and glucose oxidase using capillary electrophoresis
    Hu, P
    Luo, GA
    Wang, RJ
    Dong, RA
    Song, XQ
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1997, 18 (09): : 1459 - 1461
  • [24] THIN-FILM BIOSENSOR FOR THE MEASUREMENT OF GLUCOSE-CONCENTRATION IN HUMAN SERUM AND URINE
    YU, PG
    ZHOU, D
    ANALYTICA CHIMICA ACTA, 1995, 300 (1-3) : 91 - 97
  • [25] Detection of Human Plasma Glucose Using a Self-Powered Glucose Biosensor
    Slaughter, Gymama
    Kulkarni, Tanmay
    ENERGIES, 2019, 12 (05)
  • [26] Enzymatic in-capillary derivatization for glucose determination by electrophoresis with spectrophotometric detection
    Rzygalinski, Ignacy
    Pobozy, Ewa
    Drewnowska, Renata
    Trojanowicz, Marek
    ELECTROPHORESIS, 2008, 29 (08) : 1741 - 1748
  • [27] Determination of ribavirin in human serum and plasma by capillary electrophoresis
    Breadmore, MC
    Theurillat, R
    Thormann, W
    ELECTROPHORESIS, 2004, 25 (10-11) : 1615 - 1622
  • [28] CAPILLARY ELECTROPHORESIS OF HUMAN SERUM-PROTEINS AND APOLIPOPROTEINS
    LEHMANN, R
    LIEBICH, H
    GRUBLER, G
    VOELTER, W
    ELECTROPHORESIS, 1995, 16 (06) : 998 - 1001
  • [29] Determination of fosmidomycin in human serum and urine by capillary electrophoresis
    Bronner, S
    Renault, C
    Hintz, M
    Wiesner, J
    Jomaa, H
    Monteil, H
    Jehl, F
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 806 (02): : 255 - 261
  • [30] Determination of antiretroviral agents in human serum by capillary electrophoresis
    Pereira, EA
    Micke, GA
    Tavares, MFM
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1091 (1-2) : 169 - 176