Glucose in human serum determined by capillary electrophoresis with glucose micro-biosensor

被引:21
|
作者
Wang, Xiaolei [1 ,2 ]
Zhang, Yan [1 ]
Cheng, Cuicui [1 ]
Dong, Ranran [1 ]
Hao, Jingcheng [3 ]
机构
[1] Shandong Normal Univ, Coll Chem Chem Engn & Mat Sci, Engn Res Ctr Pesticide & Med Intermediate Clean P, Key Lab Mol & Nano Probes,Minist Educ,Shandong Pr, Jinan 250014, Peoples R China
[2] Shandong Univ, Inst Crystal Mat, Jinan 250100, Peoples R China
[3] Shandong Univ, Minist Educ, Key Lab Colloid & Interface Chem, Jinan 250100, Peoples R China
关键词
ELECTROCHEMICAL DETECTION; GOLD NANOPARTICLE; REDOX ENZYMES; OXIDASE; ELECTRODE; SENSOR; FILM; IMMOBILIZATION; PRECOLUMN; BILAYER;
D O I
10.1039/c0an00348d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glucose micro-biosensor was employed as detector in capillary electrophoresis (CE) for determining the concentration of glucose in human serum. The micro-biosensor was based on the immobilization of the SWNTs-glucose oxidase-chitosan biocomposite at a platinized Au electrode by electrodeposition. The influencing factors including separation voltage, detection potential, pH value, and the concentration of the buffer were studied. Suitable conditions were obtained for the determination of glucose: running buffer, 25 mM PBS (pH 8.0); separation field strength, 250 V cm(-1); detection potential, 0.80 V vs. saturated calomel electrode. Under optimized detection conditions, glucose responded linearly from the range of 5 mM to 1 mM with a correlation coefficient of 0.9986 for the injection voltage of 5.0 kV and injection time of 10 s. The concentration limit of detection of the method was 1 mM (S/N 3). The micro-biosensor exhibited good stability and durability in the analytical procedures. The relative standard deviation of the migration time and peak current were 1.7% and 2.6%, respectively. Glucose in human serum from two healthy individuals and two diabetics was successfully determined, giving a good prospect for a new clinical diagnostic instrument.
引用
收藏
页码:1753 / 1759
页数:7
相关论文
共 50 条
  • [1] Determination of glucose in human stomach cancer cell extracts and single cells by capillary electrophoresis with a micro-biosensor
    Wang, Xiaolei
    Ma, Yanfang
    Zhao, Man
    Zhou, Minfeng
    Xiao, Yan
    Sun, Zifei
    Tong, Lili
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1469 : 128 - 134
  • [2] Preparation of micro-biosensor for continuous glucose monitoring
    Yasuzawa, Mikito
    Toba, Taketo
    Hiura, Kentaro
    Li, Jiang
    Koinkar, Pankaj M.
    Ueki, Tomoyuki
    Fuchiwaki, Yusuke
    MODERN PHYSICS LETTERS B, 2015, 29 (6-7):
  • [3] FAST DETERMINATION OF WHOLE-BLOOD GLUCOSE WITH A CALORIMETRIC MICRO-BIOSENSOR
    XIE, B
    HEDBERG, U
    MECKLENBURG, M
    DANIELSSON, B
    SENSORS AND ACTUATORS B-CHEMICAL, 1993, 15 (1-3) : 141 - 144
  • [4] Amperometric Biosensor Coupled to Capillary Electrophoresis for Glucose Determination
    Gang Chen
    Yuting Wang
    Pengyuan Yang
    Microchimica Acta, 2005, 150 : 239 - 245
  • [5] Amperometric biosensor coupled to capillary electrophoresis for glucose determination
    Chen, G
    Wang, YT
    Yang, PY
    MICROCHIMICA ACTA, 2005, 150 (3-4) : 239 - 245
  • [6] Glucose micro-biosensor for scanning electrochemical microscopy characterization of cellular metabolism in hypoxic microenvironments
    De Zio, Simona
    Becconi, Maila
    Solda, Alice
    Malferrari, Marco
    Lesch, Andreas
    Rapino, Stefania
    BIOELECTROCHEMISTRY, 2023, 150
  • [7] IOHEXOL IN SERUM DETERMINED BY CAPILLARY ELECTROPHORESIS
    SHIHABI, ZK
    CONSTANTINESCU, MS
    CLINICAL CHEMISTRY, 1992, 38 (10) : 2117 - 2120
  • [8] Novel biosensor capable of monitoring glucose in human serum
    Yoon, Hye Joo
    Yoon, Dong Joo
    Bae, Hojae
    Lee, Ji Hoon
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 240
  • [9] An optical biosensor for the rapid determination of glucose in human serum
    Wang, Xu-Dong
    Zhou, Ting-Yao
    Chen, Xi
    Wong, Kwok-Yin
    Wang, Xiao-Ru
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 129 (02) : 866 - 873