Risk for Radiation-Induced Cataract for Staff in Interventional Cardiology: Is There Reason for Concern?

被引:262
作者
Ciraj-Bjelac, Olivera [2 ]
Rehani, Madan M. [1 ]
Sim, Kui Hian [3 ]
Liew, Houng Bang [3 ]
Vano, Eliseo [4 ]
Kleiman, Norman J. [5 ]
机构
[1] IAEA, A-1400 Vienna, Austria
[2] Vinca Inst Nucl Sci, Belgrade, Serbia
[3] Sarawak Gen Hosp, Dept Cardiol, Kuching, Malaysia
[4] Univ Complutense, Dept Radiol, E-28040 Madrid, Spain
[5] Columbia Univ, Mailman Sch Publ Hlth, Dept Environm Hlth Sci, New York, NY USA
关键词
cardiac catheterization; fluoroscopy; occupational exposure; posterior subcapsular cataract (psc); lens opacity; IONIZING-RADIATION; EXPOSURE; LENS; RADIOLOGY; OPACITIES; HAZARDS;
D O I
10.1002/ccd.22670
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To examine the prevalence of radiation-associated lens opacities among interventional cardiologists and nurses and correlate with occupational radiation exposure. Background: Interventional cardiology personnel are exposed to relatively high levels of X-rays and based on recent findings of radiation-associated lens opacities in other cohorts, they may be at risk for cataract without use of ocular radiation protection. Methods: Eyes of interventional cardiologists, nurses, and age-and sex-matched unexposed controls were screened by dilated slit lamp examination and posterior lens changes graded using a modified Merriam-Focht technique. Individual cumulative lens X-ray exposure was calculated from responses to a questionnaire and personal interview. Results: The prevalence of radiation-associated posterior lens opacities was 52% (29/56, 95% CI: 35-73) for interventional cardiologists, 45% (5/11, 95% CI: 15-100) for nurses, and 9% (2/22, 95% CI: 1-33) for controls. Relative risks of lens opacity was 5.7 (95% CI: 1.5-22) for interventional cardiologists and 5.0 (95% CI: 1.2-21) for nurses. Estimated cumulative ocular doses ranged from 0.01 to 43 Gy with mean and median values of 3.4 and 1.0 Gy, respectively. A strong dose-response relationship was found between occupational exposure and the prevalence of radiation-associated posterior lens changes. Conclusions: These findings demonstrate a dose dependent increased risk of posterior lens opacities for interventional cardiologists and nurses when radiation protection tools are not used. While study of a larger cohort is needed to confirm these findings, the results suggest ocular radio-protection should be utilized. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:826 / 834
页数:9
相关论文
共 50 条
[1]   Radiation Cataractogenesis: A Review of Recent Studies [J].
Ainsbury, E. A. ;
Bouffler, S. D. ;
Doerr, W. ;
Graw, J. ;
Muirhead, C. R. ;
Edwards, A. A. ;
Cooper, J. .
RADIATION RESEARCH, 2009, 172 (01) :1-9
[2]  
[Anonymous], 1995, 122 NCRP
[3]   GUIDELINES FOR PERSONNEL RADIATION MONITORING IN THE CARDIAC-CATHETERIZATION LABORATORY [J].
BALTER, S .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 30 (04) :277-279
[4]  
Balter S, 1999, CATHETER CARDIO INTE, V47, P229, DOI 10.1002/(SICI)1522-726X(199906)47:2<229::AID-CCD23>3.3.CO
[5]  
2-N
[6]   Patient radiation doses during cardiac catheterization procedures [J].
Betsou, S ;
Efstathopoulos, EP ;
Katritsis, D ;
Faulkner, K ;
Panayiotakis, G .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (846) :634-639
[7]  
Blakely E A, 2010, Radiat Res, V173, P709, DOI 10.1667/RRXX19.1
[8]   Statistics notes - The odds ratio [J].
Bland, JM ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 2000, 320 (7247) :1468-1468
[9]   The lens is more sensitive to radiation than we had believed [J].
Brown, NP .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1997, 81 (04) :257-257
[10]  
Caulfield LE, 1999, AM J CLIN NUTR, V69, P237