Construction of a cryogen-free thermal desorption gas chromatographic system with off-the-shelf components for monitoring ambient volatile organic compounds

被引:5
作者
Ou-Yang, Chang-Feng [1 ,2 ]
Liao, Wei-Cheng [1 ]
Wang, Pei-Chieh [1 ]
Fan, Gang-Jei [1 ]
Hsiao, Chien-Cheng [1 ]
Chuang, Ming-Tung [3 ]
Chang, Chih-Chung [4 ]
Lin, Neng-Huei [2 ]
Wang, Jia-Lin [1 ]
机构
[1] Natl Cent Univ, Dept Chem, Taoyuan 32001, Taiwan
[2] Natl Cent Univ, Dept Atmospher Sci, Taoyuan 32001, Taiwan
[3] Natl Cent Univ, Grad Inst Energy Engn, Taoyuan 32001, Taiwan
[4] Acad Sinica, Res Ctr Environm Changes, Taipei 115, Taiwan
关键词
Air quality; Deans switch; Ethylene; Ozone precursors; SPECTROMETRY PTR-MS; REAL-TIME ANALYSIS; MASS-SPECTROMETRY; OZONE PRECURSORS; HYDROCARBONS; CHEMISTRY; EMISSIONS; TRAP; VOCS; SITE;
D O I
10.1002/jssc.201501336
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated gas chromatographic system aimed at performing unattended measurements of ambient volatile organic compounds was configured and tested. By exploiting various off-the-shelf components, the thermal desorption unit was easily assembled and can be connected with any existing commercial gas chromatograph in the laboratory to minimize cost. The performance of the complete thermal desorption gas chromatographic system was assessed by analyzing a standard mixture containing 56 target nonmethane hydrocarbons from C-2-C-12 at sub-ppb levels. Particular attention was given to the enrichment efficiency of the C-2 compounds, such as ethane (b.p. = -88.6 degrees C) and ethylene (b.p. = -104.2 degrees C), due to their extremely high volatilities. Quality assurance was performed in terms of the linearity, precision and limits of detection of the target compounds. To further validate the system, field measurements of target compounds in ambient air were compared with those of a commercial total hydrocarbon analyzer and a carbon monoxide analyzer. Highly coherent results from the three instruments were observed during a two-month period of synchronized measurements. Moreover, the phenomenon of opposite diurnal variations between the biogenic isoprene and anthropogenic species was exploited to help support the field applicability of the thermal desorption gas chromatographic method.
引用
收藏
页码:1489 / 1499
页数:11
相关论文
共 42 条
[1]   Atmospheric chemistry of VOCs and NOx [J].
Atkinson, R .
ATMOSPHERIC ENVIRONMENT, 2000, 34 (12-14) :2063-2101
[2]  
Blake N.J., 2002, ENCY ATMOSPHERIC SCI, P2438
[3]   Demonstration of proton-transfer reaction time-of-flight mass spectrometry for real-time analysis of trace volatile organic compounds [J].
Blake, RS ;
Whyte, C ;
Hughes, CO ;
Ellis, AM ;
Monks, PS .
ANALYTICAL CHEMISTRY, 2004, 76 (13) :3841-3845
[4]   CHROMATOGRAPHIC CRYOFOCUSING AND CRYOTRAPPING WITH THE VORTEX TUBE [J].
BRUNO, TJ .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1994, 32 (03) :112-115
[5]  
CARTER WPL, 1994, J AIR WASTE MANAGE, V44, P881
[6]   Network monitoring of speciated vs. total non-methane hydrocarbon measurements [J].
Chen, Sheng-Po ;
Liao, Wei-Cheng ;
Chang, Chih-Chung ;
Su, Yuan-Chang ;
Tong, Yu-Huei ;
Chang, Julius S. ;
Wang, Jia-Lin .
ATMOSPHERIC ENVIRONMENT, 2014, 90 :33-42
[7]  
Ciccioli P., 1999, Reactive Hydrocarbons in the Atmosphere, P159, DOI [10.1016/B978-012346240-4/50006-0, DOI 10.1016/B978-012346240-4/50006-0]
[8]   USE OF HEART CUTTING IN GAS-CHROMATOGRAPHY - A REVIEW [J].
DEANS, DR .
JOURNAL OF CHROMATOGRAPHY, 1981, 203 (JAN) :19-28
[9]   ADSORPTION CHROMATOGRAPHY ON PLOT (POROUS-LAYER OPEN-TUBULAR) COLUMNS - A NEW LOOK AT THE FUTURE OF CAPILLARY GC [J].
DEZEEUW, J ;
DENIJS, RCM ;
HENRICH, LT .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1987, 25 (02) :71-83
[10]  
Finlayson-Pitts B.J., 2000, Chemistry of the Upper and Lower Atmosphere: Theory, Experiments, and Applications, Vfirst