Appraising the Seismic Response of a Retrofitted Adobe Historic Structure, the Role of Modal Updating and Advanced Computations

被引:10
作者
Ahmadi, Seyed Salar [1 ]
Karanikoloudis, Georgios [1 ]
Mendes, Nuno [1 ]
Illambas, Rogiros [1 ]
Lourenco, Paulo B. [1 ]
机构
[1] Univ Minho, Dept Civil Engn, ISISE, P-4800058 Guimaraes, Portugal
关键词
adobe church; strengthening of historical constructions; in situ survey; non-destructive test campaign; FE modeling; modal updating; static nonlinear analysis; performance-based seismic assessment; BEHAVIOR;
D O I
10.3390/buildings12111795
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The concepts of structural assessment and retrofit of historical constructions are of particular complexity and require advanced knowledge in material science, conservation techniques and structural analysis. In particular, adobe constructions, given their low mechanical properties and brittle failure modes, are in immense need of comprehensive assessment and retrofitting plans. The current work focuses on the adobe Church of Kunotambo in Peru, having experienced long periods of deterioration and earthquake-related damage. Under the ongoing Seismic Retrofitting Project (SRP) of the Getty Conservation Institute (GCI), the structural assessment of the church initiated in 2015 confirmed the low lateral capacity of the building and the poor connectivity between the structural parts. Based on the existing cracks and damage, a strengthening scheme was optimized and validated. After the implementation of the retrofitting plan, the quality of its execution and efficiency were assessed in 2019 with a new in situ campaign, which included ambient vibration testing (AVT) and sonic testing. From the acquired field data, the FE model of the retrofitted church was optimized, by updating the stiffness properties of masonry and discontinuities. Moreover, nonlinear static analyses were performed on the updated model in all in-plan directions. Finally, a displacement-based performance assessment was undertaken, under different earthquake limit states, demonstrating the adequacy of the retrofitting.
引用
收藏
页数:34
相关论文
共 44 条
[1]  
AIC, 1994, AIC COD ETH GUID PRA
[2]  
[Anonymous], 2014, ASCE/SEI 41-13, DOI DOI 10.1061/9780784412855
[3]  
[Anonymous], 2004, EUROCODE 8 DESIGN ST
[4]  
[Anonymous], 2020, DIANA USERS MANUAL
[5]  
[Anonymous], 2016, E030 TECHN STAND BUI
[6]  
[Anonymous], 2017, SEISMIC RETROFITTING
[7]  
[Anonymous], 2006, RNE E 10 TECHN NORM
[8]  
[Anonymous], 2006, ARTEMIS EXTRACTOR PR
[9]  
Blondet M., 2008, P 14 WORLD C EARTHQ
[10]  
Cancino C., 2011, DAMAGE ASSESSMENT HI