Effect of Saturated Steam Carried Downward on the Flow Properties in the Downcomer of Steam Generator

被引:0
|
作者
Liu, Yan [1 ,2 ]
Shi, Hui-lie [2 ]
Gui, Chun [2 ]
Wang, Xian-yuan [1 ,2 ]
Tian, Rui-feng [2 ]
机构
[1] Harbin Engn Univ, Fundamental Sci Nucl Safety & Simulat Technol Lab, Harbin 150001, Heilongjiang, Peoples R China
[2] Res Inst Nucl Power Operat, Wuhan 430223, Hubei, Peoples R China
关键词
direct contact and condensation of steam; natural circulation steam generator; downcomer; condensation model; DIRECT-CONTACT CONDENSATION; NUMERICAL-SIMULATION; HEAT-TRANSFER; PATTERN; WATER; JET;
D O I
10.3390/en12193650
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The saturated water separated by the steam separator in a natural circulation steam generator may carry a small amount of saturated steam into the downcomer. The steam contacts subcooled water and condenses directly in the downcomer causing the variations in the pressure and steam quality and likely affecting the stability of the water cycle in the secondary loop. It is not conducive to core heat extraction and thus affects nuclear safety. The mathematical model of the downcomer was established in this study based on the internal structures of a natural circulation steam generator. The volume-of-fluid (VOF) and large-eddy-simulation (LES) models were used for analysis on FLUENT software (ANSYS, Pittsburgh, PA. USA) platform. The influence of direct contact condensation of top-down flowing steam on the flow properties in the downcomer of the steam generator under high pressure was studied. The trend of the temperature, pressure, and the void fraction were obtained by combining these models with the condensation model. Further, a one-dimensional calculation program based on the differential drop was also developed to assess the flow field in the downcomer. The calculation results are in good agreement with the experimental results which indicated that, when affected by the saturated steam carried downward, the flow temperature close to the exit of the downcomer rises slightly due to the absorption of the heat released by the steam condensation. Furthermore, the density corrected by the pressure-drop is more reliable than that corrected by the temperature. After the velocity in the downcomer has increased to a certain value, the sensitivity of steam quality to the subcooling degree in the downcomer begins to decline. The results in this paper can be used to perform stability analyses and to design steam generators. The results of research are helpful to the stability analysis and the design of a steam generator, and to improve the accuracy of the measurement of the steam generator operating parameters, thus enhancing the safety of Pressurize Water Reactor operating system.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] Investigation of the Heat-Insulation Properties of the Steam-Water Gap in the Downcomer Pipes of a Steam Generator
    A. A. Semchenkov
    O. Yu. Novosel’skii
    Yu. V. Lemekhov
    A. G. Khizhnyak
    S. V. Shpanskii
    V. P. Shishov
    Atomic Energy, 2014, 115 : 294 - 299
  • [2] Investigation of the Heat-Insulation Properties of the Steam-Water Gap in the Downcomer Pipes of a Steam Generator
    Semchenkov, A. A.
    Novosel'skii, O. Yu.
    Lemekhov, Yu. V.
    Khizhnyak, A. G.
    Shpanskii, S. V.
    Shishov, V. P.
    ATOMIC ENERGY, 2014, 115 (05) : 294 - 299
  • [3] Properties of saturated steam
    不详
    JOURNAL OF THE FRANKLIN INSTITUTE, 1934, 218 : 262 - 264
  • [4] Ultrasonic downcomer flow measurements for recirculating steam generators
    Janzen, Victor
    Luloff, Brian
    Sedman, Ken
    NUCLEAR ENGINEERING AND DESIGN, 2015, 289 : 266 - 277
  • [5] CALCULATION OF SATURATED STEAM PROPERTIES
    JAGANNATH, S
    TAPPI JOURNAL, 1986, 69 (12): : 142 - 143
  • [6] COMPUTING PROPERTIES OF SATURATED STEAM
    WILLIAMS.IM
    CHEMICAL ENGINEERING, 1972, 79 (11) : 128 - &
  • [7] DOWN STEAM-WATER FLOW STEAM-GENERATOR
    WORLEY, NG
    NUCLEAR ENERGY-JOURNAL OF THE BRITISH NUCLEAR ENERGY SOCIETY, 1980, 19 (04): : 297 - 302
  • [8] DOWN STEAM-WATER FLOW STEAM GENERATOR.
    Worley, N.G.
    Nuclear Energy, 1980, 19 (04): : 297 - 302
  • [9] Steam generator tube flow rate regulation of HTGR steam generator test loop
    Li, Xiao-Wei
    Wu, Xin-Xin
    Ju, Huai-Ming
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2012, 46 (SUPPL.2): : 859 - 862
  • [10] Investigation of Probable Cause of Premature Cracking of Downcomer Nozzle of Heat Recovery Steam Generator
    Ghosh, D.
    Roy, H.
    Shukla, A. K.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2009, 9 (06) : 517 - 521