A Ten-Year Radiostereometric Analysis of Polyethylene Wear Between Oxidized Zirconium and Cobalt Chrome Articulations in Total Hip Arthroplasty

被引:6
作者
Salipas, Andrew [1 ]
Poole, Andrew S. [1 ]
Teeter, Matthew G. [1 ]
Somerville, Lyndsay E. [1 ]
Naudie, Douglas D. [1 ]
McCalden, Richard W. [1 ]
机构
[1] London Hlth Sci, Div Orthopaed Surg, Dept Surg, London, ON, Canada
关键词
wear; highly-crosslinked polyethylene; femoral head; total hip arthroplasty; oxidized zirconium; cobalt chromium; CROSS-LINKED POLYETHYLENE; RANDOMIZED CONTROLLED-TRIAL; FEMORAL HEADS; CLINICAL-OUTCOMES; OXINIUM; RATES; THAS;
D O I
10.1016/j.arth.2022.02.099
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Oxidized zirconium (OxZi) femoral heads combine the decreased abrasive properties of ceramics with the toughness of metal alloys to lower wear and increase the durability of total hip arthroplasty. The purpose of this study was to compare the 10-year polyethylene wear rates between OxZi/XLPE and cobalt chrome (CoCr)/XLPE articulations. Methods: A radiostereometric analysis (RSA) was performed on two cohorts of 23 patients who underwent total hip arthroplasty using either OxZi/XLPE or CoCr/XLPE at a minimum of 10-year follow-up. Cohorts were matched for age, gender, body mass index (BMI), and diagnosis. Polyethylene wear was measured using RSA to determine total and steady-state wear rates for both cohorts. Preoperative and postoperative patient-reported outcome measures (SF12, HHS, and Western Ontario and McMaster Universities Arthritis Index scores) were compared. Results: The mean total head penetration rate was found to be statistically different between the entire cohorts (OxZi 0.048 +/- 0.021 mm/y, CoCr 0.035 +/- 0.017 mm/y, P = .02) but not when 28-mm heads only (OxZi 0.045 +/- 0.016 mm/y, CoCr 0.034 +/- 0.017 mm/y, P = .066) were directly compared. The mean steady-state wear rate was not significantly different between the entire cohorts (OxZi 0.031 +/- 0.021 mm/y, CoCr 0.024 +/- 0.019 mm/y, P = .24) or 28-mm head cohorts (OxZi 0.028 +/- 0.019 mm/y, CoCr 0.024 +/- 0.019 mm/y, P = .574). Outcome measures showed no statistical difference except for the Harris Hip Score where the OxZi cohort demonstrated higher median scores. Conclusion: Using RSA to evaluate the 10-year in-vivo head penetration, there was no statistically significant difference in steady-state wear rates between OxZi and CoCr articulations. Both bearing combinations demonstrated wear rates well below the threshold for osteolysis. (C) 2022 Elsevier Inc. All rights reserved.
引用
收藏
页码:S692 / S696
页数:5
相关论文
共 26 条
[1]  
[Anonymous], 2021, NASA Aerospace Safety Advisory Panel Annual Report, Annual Report for 2020
[2]  
[Anonymous], 2015, BONE JOINT J, V97, P1463
[3]   Polyethylene Wear With Ceramic and Metal Femoral Heads at 5 Years: A Randomized Controlled Trial With Radiostereometric Analysis [J].
Bergvinsson, Halldor ;
Sundberg, Martin ;
Flivik, Gunnar .
JOURNAL OF ARTHROPLASTY, 2020, 35 (12) :3769-3776
[4]  
Bottner F, 2005, HSS J, V1, P94, DOI 10.1007/s11420-005-0114-2
[5]   CHARNLEY LOW-FRICTION TOTAL HIP REPLACEMENT [J].
CAMPBELL, RE ;
ROTHMAN, RH .
AMERICAN JOURNAL OF ROENTGENOLOGY RADIUM THERAPY AND NUCLEAR MEDICINE, 1971, 113 (04) :634-&
[6]   Center index methodan alternative for wear measurements with radiostereometry (RSA) [J].
Dahl, Jon ;
Figved, Wender ;
Snorrason, Finnur ;
Nordsletten, Lars ;
Rohrl, Stephan M. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (03) :480-484
[7]  
Davis Edward T, 2020, JB JS Open Access, V5, pe0075, DOI [10.2106/jbjs.oa.19.00075, 10.2106/JBJS.OA.19.00075]
[8]   A literature review of the association between wear rate and osteolysis in total hip arthroplasty [J].
Dumbleton, JH ;
Manley, MT ;
Edidin, AA .
JOURNAL OF ARTHROPLASTY, 2002, 17 (05) :649-661
[9]   Estimating the osteolysis-free life of a total hip prosthesis depending on the linear wear rate and head size [J].
Elke, Reinhard ;
Rieker, Claude B. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2018, 232 (08) :753-758
[10]   Low Wear Rates Seen in THAs With Highly Crosslinked Polyethylene at 9 to 14 Years in Patients Younger Than Age 50 Years [J].
Garvin, Kevin L. ;
White, Tyler C. ;
Dusad, Anand ;
Hartman, Curtis W. ;
Martell, John .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (12) :3829-3835