Empowering Technology Enabled Care Using IoT and Smart Devices: A Review

被引:41
作者
Baali, Hamza [1 ,2 ]
Djelouat, Hamza [1 ]
Amira, Abbes [1 ]
Bensaali, Faycal [1 ]
机构
[1] Qatar Univ, Coll Engn, Doha, Qatar
[2] Hamad Bin Khalifa Univ, Coll Sci & Engn, Doha, Qatar
关键词
Connected health; compressed sensing; energy efficiency; IoT; wearable devices; SIGNAL-QUALITY INDEXES; LOW-POWER; BLOOD-PRESSURE; MU-W; SAR ADC; INSTRUMENTATION AMPLIFIER; INTEGRATED-CIRCUITS; WEARABLE DEVICES; DATA-COMPRESSION; SENSOR NETWORKS;
D O I
10.1109/JSEN.2017.2786301
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Designing power aware wearable devices is the main key in building compact size autonomous smart devices to successfully connect health Internet of things solutions. With their ability to perform tasks ranging from simple self-monitoring to complex interactive tasks, these devices hold great promises in providing a large scale cost effective solution to the challenges facing nowadays healthcare systems. Despite the advances in sensing and hardware design, there still remain several technical challenges facing the research community to build devices that meet the computational requirements with a self-powered capability. Overcoming these challenges require major improvements in all the building blocks of wearable devices including sensors, power management, signal processing, computing architectures, and communication. This paper surveys some of the past milestones related to these subsystems and discusses promising research directions addressing their limitations.
引用
收藏
页码:1790 / 1809
页数:20
相关论文
共 169 条
[1]   A Multichannel EEG Acquisition Scheme Based on Single Ended Amplifiers and Digital DRL [J].
Alejandro Haberman, Marcelo ;
Mario Spinelli, Enrique .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2012, 6 (06) :614-618
[2]  
[Anonymous], 2015, Sampling Theory: Beyond Bandlimited Systems
[3]  
[Anonymous], 2014, 1708 IEEE STAND ASS
[4]  
[Anonymous], 2001, Multiresolution Signal Decompo-sition: Transforms, Subbands, and Wavelets
[5]  
ARM Ltd, 2015, BIG LITTL WHIT PAP
[6]  
Artan N. S., 2017, BIOMEDICAL ENG CONCE, P413
[7]  
Baraniuk R., 2006, PREPRINT, V100, P1
[8]  
Barth AT, 2009, SIXTH INTERNATIONAL WORKSHOP ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS, PROCEEDINGS, P71, DOI [10.1109/BSN.2009.39, 10.1109/P3644.38]
[9]   THE DURATION OF HOLTER MONITORING IN PATIENTS WITH SYNCOPE - IS 24 HOURS ENOUGH [J].
BASS, EB ;
CURTISS, EI ;
ARENA, VC ;
HANUSA, BH ;
CECCHETTI, A ;
KARPF, M ;
KAPOOR, WN .
ARCHIVES OF INTERNAL MEDICINE, 1990, 150 (05) :1073-1078
[10]   Low-Power ECG-Based Processor for Predicting Ventricular Arrhythmia [J].
Bayasi, Nourhan ;
Tekeste, Temesghen ;
Saleh, Hani ;
Mohammad, Baker ;
Khandoker, Ahsan ;
Ismail, Mohammed .
IEEE TRANSACTIONS ON VERY LARGE SCALE INTEGRATION (VLSI) SYSTEMS, 2016, 24 (05) :1962-1974