DEVELOPMENT OF SOLID CONTACT MICROPIPETTE Zn-ION SELECTIVE ELECTRODE FOR CORROSION STUDIES

被引:11
作者
Varga, Agnes [1 ]
Nagy, Livia [1 ]
Izquierdo, Javier [2 ]
Bitter, Istvan [3 ]
Souto, Ricardo M. [2 ]
Nagy, Geza [2 ]
机构
[1] Univ Pecs, Dept Gen & Phys Chem, H-7624 Pecs, Hungary
[2] Univ La Laguna, Dept Phys Chem, Tenerife, Spain
[3] Budapest Univ Technol & Econ, Budapest, Hungary
关键词
Corrosion; SECM; Zinc ion selective electrode; SCANNING ELECTROCHEMICAL MICROSCOPY; CONCENTRATION PROFILES; DEGRADATION PROCESSES; GALVANIC CORROSION; FAST-RESPONSE; SVET; SENSOR; SECM;
D O I
10.1080/00032719.2011.582545
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Micron-size ion selective micropipettes can be used in scanning electrochemical microscopy (SECM). They can provide excellent spatial resolution. Unfortunately the resistance of these small sensors is high. Their application needs special shielding and slow scanning rates. Usually their lifetime hardly exceeds a few days. Zinc layer or dispersed zinc particles containing films are often used for providing cathodic protection against corrosion in case of metal surfaces. Therefore, in corrosion studies, measurements of local zinc ion concentration can give important information about the nature of the process. For corrosion studies we needed SECM measuring tips for imaging concentration profiles of Zn(2+)ions involved in surface processes. Based on our earlier experience, solid contact micropipettes for selective measurements of Zn(2+)ion concentration were prepared with a tip size of a few micrometers. The properties of the micropipettes were investigated. They were also used in SECM imaging. In this paper, details of Zn(2+)ion selective microelectrode preparation are described. Data about their properties, lifetime, resistance, and ion activity response are shown. Preliminary findings in SECM imaging of zinc ion concentration profiles are shown. The improvement of the scanning rate achieved by lowering tip resistance is a main advantage in potentiometric SECM.
引用
收藏
页码:2876 / 2886
页数:11
相关论文
共 28 条
[21]   Use of SVET and SECM to study the galvanic corrosion of an-iron-zinc cell [J].
Simoes, A. M. ;
Bastos, A. C. ;
Ferreira, M. G. ;
Gonzalez-Garcia, Y. ;
Gonzalez, S. ;
Souto, R. M. .
CORROSION SCIENCE, 2007, 49 (02) :726-739
[22]   Corrosion inhibition at galvanized steel cut edges by phosphate pigments [J].
Simoes, A. M. ;
Torres, J. ;
Picciochi, R. ;
Fernandes, J. C. S. .
ELECTROCHIMICA ACTA, 2009, 54 (15) :3857-3865
[23]   Investigating corrosion processes in the micrometric range:: A SVET study of the galvanic corrosion of zinc coupled with iron [J].
Souto, R. M. ;
Gonzalez-Garcia, Y. ;
Bastos, A. C. ;
Simoes, A. M. .
CORROSION SCIENCE, 2007, 49 (12) :4568-4580
[24]  
Souto R. M., 2010, MICROSCOPY SCI TECHN, V4
[25]   SECM Imaging of Interfacial Processes in Defective Organic Coatings Applied on Metallic Substrates Using Oxygen as Redox Mediator [J].
Souto, Ricardo M. ;
Fernandez-Merida, Luis ;
Gonzalez, Sergio .
ELECTROANALYSIS, 2009, 21 (24) :2640-2646
[26]   Scanning electrochemical microscopy measurement of ferrous ion fluxes during localized corrosion of steel [J].
Völker, E ;
Inchauspe, CG ;
Calvo, EJ .
ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (01) :179-183
[27]   SCANNING ELECTROCHEMICAL MICROSCOPY .28. ION-SELECTIVE NEUTRAL CARRIER-BASED MICROELECTRODE POTENTIOMETRY [J].
WEI, C ;
BARD, AJ ;
NAGY, G ;
TOTH, K .
ANALYTICAL CHEMISTRY, 1995, 67 (08) :1346-1356
[28]   Zinc(II) PVC-based membrane sensor based on 5,6-benzo-4,7,13,16,21,24-hexaoxa-1,10-diazabicyclo[8,8,8]hexacos-5-ene [J].
Zamani, HA ;
Ganjali, MR ;
Pooyamanesh, MJ .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2006, 17 (01) :149-155