DEVELOPMENT OF SOLID CONTACT MICROPIPETTE Zn-ION SELECTIVE ELECTRODE FOR CORROSION STUDIES

被引:11
作者
Varga, Agnes [1 ]
Nagy, Livia [1 ]
Izquierdo, Javier [2 ]
Bitter, Istvan [3 ]
Souto, Ricardo M. [2 ]
Nagy, Geza [2 ]
机构
[1] Univ Pecs, Dept Gen & Phys Chem, H-7624 Pecs, Hungary
[2] Univ La Laguna, Dept Phys Chem, Tenerife, Spain
[3] Budapest Univ Technol & Econ, Budapest, Hungary
关键词
Corrosion; SECM; Zinc ion selective electrode; SCANNING ELECTROCHEMICAL MICROSCOPY; CONCENTRATION PROFILES; DEGRADATION PROCESSES; GALVANIC CORROSION; FAST-RESPONSE; SVET; SENSOR; SECM;
D O I
10.1080/00032719.2011.582545
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Micron-size ion selective micropipettes can be used in scanning electrochemical microscopy (SECM). They can provide excellent spatial resolution. Unfortunately the resistance of these small sensors is high. Their application needs special shielding and slow scanning rates. Usually their lifetime hardly exceeds a few days. Zinc layer or dispersed zinc particles containing films are often used for providing cathodic protection against corrosion in case of metal surfaces. Therefore, in corrosion studies, measurements of local zinc ion concentration can give important information about the nature of the process. For corrosion studies we needed SECM measuring tips for imaging concentration profiles of Zn(2+)ions involved in surface processes. Based on our earlier experience, solid contact micropipettes for selective measurements of Zn(2+)ion concentration were prepared with a tip size of a few micrometers. The properties of the micropipettes were investigated. They were also used in SECM imaging. In this paper, details of Zn(2+)ion selective microelectrode preparation are described. Data about their properties, lifetime, resistance, and ion activity response are shown. Preliminary findings in SECM imaging of zinc ion concentration profiles are shown. The improvement of the scanning rate achieved by lowering tip resistance is a main advantage in potentiometric SECM.
引用
收藏
页码:2876 / 2886
页数:11
相关论文
共 28 条
[1]   LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS [J].
AMMANN, D ;
PRETSCH, E ;
SIMON, W ;
LINDNER, E ;
BEZEGH, A ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) :119-129
[2]   Micropotentiometric mapping of local distributions of Zn2+ relevant to corrosion studies [J].
Bastos, A. C. ;
Taryba, M. G. ;
Karavai, O. V. ;
Zheludkevich, M. L. ;
Lamaka, S. V. ;
Ferreira, M. G. S. .
ELECTROCHEMISTRY COMMUNICATIONS, 2010, 12 (03) :394-397
[3]   Imaging concentration profiles of redox-active species in open-circuit corrosion processes with the scanning electrochemical microscope [J].
Bastos, AC ;
Simoes, AM ;
González, S ;
González-García, Y ;
Souto, RM .
ELECTROCHEMISTRY COMMUNICATIONS, 2004, 6 (11) :1212-1215
[4]   Investigation of concentration profiles inside operating biocatalytic sensors with scanning electrochemical microscopy (SECM) [J].
Csóka, B ;
Kovács, B ;
Nagy, G .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (2-3) :141-149
[5]  
Denuault G., 2001, POTENTIOMETRIC PROBE
[6]   Concentration mapping around copper microelectrodes studied by scanning electrochemical microscopy [J].
Gabrielli, C ;
Ostermann, E ;
Perrot, H ;
Vivier, V ;
Beitone, L ;
Mace, C .
ELECTROCHEMISTRY COMMUNICATIONS, 2005, 7 (09) :962-968
[7]   Imaging metastable pits on austenitic stainless steel in situ at the open-circuit corrosion potential [J].
González-García, Y ;
Burstein, GT ;
González, S ;
Souto, RM .
ELECTROCHEMISTRY COMMUNICATIONS, 2004, 6 (07) :637-642
[8]  
Gonzalez-Garcia Y., 2007, THESIS U LA LAGUNA T
[9]   Scanning electrochemical microscopy for the investigation of localized degradation processes in coated metals [J].
Gonzalez-Garcia, Yaiza ;
Jose Santana, Juan ;
Gonzalez-Guzman, Jorge ;
Izquierdo, Javier ;
Gonzalez, Sergio ;
Souto, Ricardo M. .
PROGRESS IN ORGANIC COATINGS, 2010, 69 (02) :110-117
[10]   A porphyrin based potentiometric sensor for Zn2+ determination [J].
Gupta, VK ;
Chauhan, DK ;
Saini, VK ;
Agarwal, S ;
Antonijevic, MM ;
Lang, H .
SENSORS, 2003, 3 (07) :223-235