Self-navigated prospective motion correction for 3D-EPI acquisition

被引:3
作者
Bayih, Samuel Getaneh [1 ,2 ]
Jankiewicz, Marcin [1 ,3 ]
Alhamud, A. [1 ,3 ,4 ,5 ]
van der Kouwe, Andre J. W. [1 ,6 ,7 ]
Meintjes, Ernesta M. [1 ,2 ,3 ]
机构
[1] Univ Cape Town, Dept Human Biol, Div Biomed Engn, Biomed Engn Res Ctr, Cape Town, South Africa
[2] Univ Cape Town, Groote Schuur Hosp, Neurosci Inst, Cape Town, South Africa
[3] Univ Cape Town, Cape Univ Body Imaging Ctr, Cape Town, South Africa
[4] Modern Pioneer Ctr, Tripoli, Libya
[5] ArSMRM MRI Training & Dev, Tripoli, Libya
[6] Massachusetts Gen Hosp, AA Martinos Ctr Biomed Imaging, Charlestown, MA USA
[7] Harvard Med Sch, Dept Radiol, Boston, MA 02115 USA
基金
新加坡国家研究基金会;
关键词
prospective motion correction; real-time; self-navigated 3D EPI; volumetric navigator; RESTING-STATE FMRI; REAL-TIME MOTION; HEAD MOTION; FUNCTIONAL MRI; VOLUMETRIC NAVIGATORS; SIGNAL; EPI; ARTIFACTS; TRACKING; QUANTIFICATION;
D O I
10.1002/mrm.29202
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Although 3D EPI is more susceptible to motion artifacts than 2D EPI, it presents some benefits for functional MRI, including the absence of spin-history artifacts, greater potential for parallel imaging acceleration, and better functional sensitivity in high-resolution imaging. Here we present a self-navigated 3D-EPI sequence suitable for prospective motion-corrected functional MRI without additional hardware or pulses. Methods For each volume acquisition, the first 24 of the 52 partitions being acquired are accumulated to a new feedback block that was added to the image reconstruction pipeline. After zero-filling the remaining partitions, the feedback block constructs a volumetric self-navigator (vSNav), co-registers it to the reference vSNav acquired during the first volume acquisition, and sends motion estimates to the sequence. The sequence then updates its FOV and acquires subsequent partitions with the adjusted FOV, until the next update is received. The sequence was validated without and with intentional motion in phantom and in vivo on a 3T Skyra. Results For phantom scans, the FOV was updated 0.704 s after acquisition of the vSNav partitions, and for in vivo scans after 0.768 s. Both phantom and in vivo data demonstrated stable motion estimates in the absence of motion. For in vivo acquisitions, prospective head-pose estimates using the vSNav's and retrospective estimates with FLIRT (FMRIB's Linear Image Registration Tool) agreed to within 0.23 mm (< 10% of the slice thickness) and 0.14 degrees in all directions. Conclusion Depending when motion occurs during a volume acquisition, the proposed method fully corrects the FOV and recovers image quality within one volume acquisition.
引用
收藏
页码:211 / 223
页数:13
相关论文
共 46 条
  • [1] Rapid full-brain fMRI with an accelerated multi shot 3D EPI sequence using both UNFOLD and GRAPPA
    Afacan, Onur
    Hoge, W. Scott
    Janoos, Firdaus
    Brooks, Dana H.
    Morocz, Istvan A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (05) : 1266 - 1274
  • [2] Real-time measurement and correction of both B0 changes and subject motion in diffusion tensor imaging using a double volumetric navigated (DvNav) sequence
    Alhamud, A.
    Taylor, Paul A.
    van der Kouwe, Andre J. W.
    Meintjes, Ernesta M.
    [J]. NEUROIMAGE, 2016, 126 : 60 - 71
  • [3] Volumetric navigators for real-time motion correction in diffusion tensor imaging
    Alhamud, A.
    Tisdall, M. Dylan
    Hess, Aaron T.
    Hasan, Khader M.
    Meintjes, Ernesta M.
    van der Kouwe, Andre J. W.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (04) : 1097 - 1108
  • [4] FUNCTIONAL MAPPING OF THE HUMAN VISUAL-CORTEX BY MAGNETIC-RESONANCE-IMAGING
    BELLIVEAU, JW
    KENNEDY, DN
    MCKINSTRY, RC
    BUCHBINDER, BR
    WEISSKOFF, RM
    COHEN, MS
    VEVEA, JM
    BRADY, TJ
    ROSEN, BR
    [J]. SCIENCE, 1991, 254 (5032) : 716 - 719
  • [5] Bernal Byron, 2012, J Clin Med Res, V4, P363, DOI 10.4021/jocmr1047w
  • [6] Separating respiratory-variation-related neuronal-activity-related fluctuations in fluctuations from fMRI
    Birn, RM
    Diamond, JB
    Smith, MA
    Bandettini, PA
    [J]. NEUROIMAGE, 2006, 31 (04) : 1536 - 1548
  • [7] Buxton RB., 2009, INTRO FUNCTIONAL MAG, P341
  • [8] Chen JYE, 2015, NEUROPSYCHOL REV, V25, P289, DOI 10.1007/s11065-015-9294-9
  • [9] Dynamic scan-plane tracking using MR position monitoring
    Derbyshire, JA
    Wright, GA
    Henkelman, RM
    Hinks, RS
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04): : 924 - 932
  • [10] ORBITAL NAVIGATOR ECHOES FOR MOTION MEASUREMENTS IN MAGNETIC-RESONANCE-IMAGING
    FU, ZW
    WANG, Y
    GRIMM, RC
    ROSSMAN, PJ
    FELMLEE, JP
    RIEDERER, SJ
    EHMAN, RL
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (05) : 746 - 753