Two-compartment exchange model for perfusion quantification using arterial spin tagging

被引:90
|
作者
Zhou, JY
Wilson, DA
Ulatowski, JA
Trajstman, RJ
van Zijl, PCM
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21205 USA
[2] Johns Hopkins Univ, Sch Med, Dept Anesthesiol & Crit Care Med, Baltimore, MD 21205 USA
[3] Kennedy Krieger Inst, FM Kirby Res Ctr Funct Brain Imaging, Baltimore, MD USA
来源
关键词
cerebral blood flow; perfusion; arterial spin labeling; water exchange; microspheres; MRI;
D O I
10.1097/00004647-200104000-00013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The original well-mixed tissue model for the arterial spin tagging techniques is extended to a two-compartment model of restricted water exchange between microvascular (blood) and extravascular (tissue) space in the parenchyma. The microvascular compartment consists of arterioles, capillaries, and venules, with the blood/tissue water exchange taking place in the capillaries. It is shown that, in the case of limited water exchange, the individual FAIR (Flow-sensitive Alternating In version Recovery) signal intensities of the two compartments are comparable in magnitude, but are not overlapped in time. It is shown that when the limited water exchange is assumed to be fast, flows quantified from the signal-intensity difference are underestimated, an effect that becomes more significant for larger flows and higher magnetic field strengths. Experimental results on cat brain at 4.7 T comparing flow data from the FAIR signal-intensity difference with those from microspheres over a cerebral blood flow range from 15 to 150 mL, 100 g(-1) min(-1) confirm these theoretic predictions. FAIR flow values with correction for restricted exchange, however, correlate well with the radioactive microsphere flow values. The limitations of the approach in terms of choice of the intercompartmental exchange rates are discussed.
引用
收藏
页码:440 / 455
页数:16
相关论文
共 50 条
  • [21] A Two-Compartment Model of VEGF Distribution in the Mouse
    Yen, Phillip
    Finley, Stacey D.
    Engel-Stefanini, Marianne O.
    Popel, Aleksander S.
    PLOS ONE, 2011, 6 (11):
  • [22] A general two-compartment model for mechanical ventilation
    Crooke, PS
    Head, JD
    Marini, JJ
    MATHEMATICAL AND COMPUTER MODELLING, 1996, 24 (07) : 1 - 18
  • [23] A two-compartment phenomenological model of a dopaminergic neuron
    Zakharov D.G.
    Kuznetsov A.S.
    Nekorkin V.I.
    Biophysics, 2010, 55 (2) : 239 - 245
  • [24] Editorial for "Two-Compartment Perfusion MR IVIM Model to Investigate Normal and Pathological Placental Tissue"
    Lu, Tao
    Wang, Yi Xiang J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 59 (03) : 892 - 893
  • [25] Impact of omission or replacement of data below the limit of quantification on parameter estimates in a two-compartment model
    Duval, V
    Karlsson, MO
    PHARMACEUTICAL RESEARCH, 2002, 19 (12) : 1835 - 1840
  • [26] Impact of Omission or Replacement of Data Below the Limit of Quantification on Parameter Estimates in a Two-Compartment Model
    Vincent Duval
    Mats O. Karlsson
    Pharmaceutical Research, 2002, 19 : 1835 - 1840
  • [27] Two-compartment model for competitive hybridization on molecular biochips
    Chechetkin, V. R.
    PHYSICS LETTERS A, 2007, 360 (4-5) : 491 - 494
  • [28] Use of a two-compartment model to predict ethanol metabolism
    Levitt, MD
    Levitt, DG
    ALCOHOLISM-CLINICAL AND EXPERIMENTAL RESEARCH, 2000, 24 (04) : 409 - 410
  • [29] Quantification of Liver Perfusion Using Multidelay Pseudocontinuous Arterial Spin Labeling
    Pan, Xinlei
    Qian, Tianyi
    Fernandez-Seara, Maria A.
    Smith, Robert X.
    Li, Kuncheng
    Ying, Kui
    Sung, Kyunghyun
    Wang, Danny J. J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (05) : 1046 - 1054
  • [30] A mathematical analysis of a two-compartment model of urea kinetics
    Smye, SW
    Will, EJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (12): : 2005 - 2014