Surgically implanted aortic valve bioprostheses deform after implantation: insights from computed tomography

被引:3
作者
Faure, Marguerite E. [1 ,2 ]
Sucha, Dominika [3 ]
Schwartz, Fides R. [4 ]
Symersky, Petr [5 ]
Bogers, Ad J. J. C. [6 ]
Gaca, Jeffrey G. [7 ]
Koweek, Lynne M. [4 ]
de Heer, Linda M. [8 ,9 ]
Budde, Ricardo P. J. [1 ]
机构
[1] Erasmus MC, Dept Radiol & Nucl Med, POB 2040, NL-3000 CA Rotterdam, Netherlands
[2] AZ Monica, Dept Radiol, Antwerp, Belgium
[3] Univ Med Ctr Utrecht, Dept Radiol, Utrecht, Netherlands
[4] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27706 USA
[5] Vrije Univ Amsterdam Med Ctr, Dept Cardiothorac Surg, Amsterdam, Netherlands
[6] Erasmus MC, Dept Cardiothorac Surg, Rotterdam, Netherlands
[7] Duke Univ, Med Ctr, Dept Cardiothorac Surg, Durham, NC 27706 USA
[8] Leiden Univ, Med Ctr, Dept Cardiothorac Surg, Leiden, Netherlands
[9] Univ Med Ctr Utrecht, Dept Cardiothorac Surg, Utrecht, Netherlands
关键词
Heart valve prosthesis; Bioprosthesis; Multidetector-row computed tomography; CALCIFICATION; REPLACEMENT; GEOMETRY; STRESS; IMPACT;
D O I
10.1007/s00330-019-06634-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective Little is known about the prevalence and degree of deformation of surgically implanted aortic biological valve prostheses (bio-sAVRs). We assessed bio-sAVR deformation using multidetector-row computed tomography (MDCT). Methods Three imaging databases were searched for patients with MDCT performed after bio-sAVR implantation. Minimal and maximal valve ring diameters were obtained in systole and/or diastole, depending on the acquired cardiac phase(s). The eccentricity index (EI) was calculated as a measure of deformation as (1 - (minimal diameter/maximal diameter)) x 100%. EI of < 5% was considered none or trivial deformation, 5-10% mild deformation, and > 10% non-circular. Indications for MDCT and implanted valve type were retrieved. Results One hundred fifty-two scans of bio-sAVRs were included. One hundred seventeen measurements were performed in systole and 35 in diastole. None or trivial deformation (EI < 5%) was seen in 67/152 (44%) of patients. Mild deformation (EI 5-10%) was seen in 59/152 (39%) and non-circularity was found in 26/152 (17%) of cases. Overall, median EI was 5.5% (IQR 3.4-7.8). In 77 patients, both systolic and diastolic measurements were performed from the same scan. For these scans, the median EI was 6.5% (IQR 3.4-10.2) in systole and 5.1% (IQR3.1-7.6) in diastole, with a significant difference between both groups (p = 0.006). Conclusions Surgically implanted aortic biological valve prostheses show mild deformation in 39% of cases and were considered non-circular in 17% of studied valves.
引用
收藏
页码:2651 / 2657
页数:7
相关论文
共 30 条
[1]   Leaflet stress and strain distributions following incomplete transcatheter aortic valve expansion [J].
Abbasi, Mostafa ;
Azadani, Ali N. .
Journal of Biomechanics, 2015, 48 (13) :3663-3671
[2]  
BERNACCA GM, 1992, J BIOMED MATER RES, V26, P959
[3]   Impact of Post-Implant SAPIEN XT Geometry and Position on Conduction Disturbances, Hemodynamic Performance, and Paravalvular Regurgitation [J].
Binder, Ronald K. ;
Webb, John G. ;
Toggweiler, Stefan ;
Freeman, Melanie ;
Barbanti, Marco ;
Willson, Alexander B. ;
Alhassan, Donya ;
Hague, Cameron J. ;
Wood, David A. ;
Leipsic, Jonathon .
JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (05) :462-468
[4]   Transcatheter Aortic Valve Replacement With the SAPIEN 3 A New Balloon-Expandable Transcatheter Heart Valve [J].
Binder, Ronald K. ;
Rodes-Cabau, Josep ;
Wood, David A. ;
Mok, Michael ;
Leipsic, Jonathon ;
De Larochelliere, Robert ;
Toggweiler, Stefan ;
Dumont, Eric ;
Freeman, Melanie ;
Willson, Alexander B. ;
Webb, John G. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (03) :293-300
[5]   Prosthesis Oversizing in Balloon-Expandable Transcatheter Aortic Valve Implantation Is Associated With Contained Rupture of the Aortic Root [J].
Blanke, Philipp ;
Reinoehl, Jochen ;
Schlensak, Christian ;
Siepe, Matthias ;
Pache, Gregor ;
Euringer, Wulf ;
Geibel-Zehender, Annette ;
Bode, Christopher ;
Langer, Mathias ;
Beyersdorf, Friedhelm ;
Zehender, Manfred .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (04) :540-548
[6]   Isolated aortic valve replacement in North America comprising 108,687 patients in 10 years: Changes in risks, valve types, and outcomes in the Society of Thoracic Surgeons National Database [J].
Brown, James M. ;
O'Brien, Sean M. ;
Wu, Changfu ;
Sikora, Jo Ann H. ;
Griffith, Bartley P. ;
Gammie, James S. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (01) :82-90
[7]   Evaluation of Multislice Computed Tomography Early After Transcatheter Aortic Valve Implantation With the Edwards SAPIEN Bioprosthesis [J].
Caudron, Jerome ;
Fares, Jeannette ;
Hauville, Camille ;
Cribier, Alain ;
Dacher, Jean-Nicolas ;
Tron, Christophe ;
Bauer, Fabrice ;
Litzler, Pierre-Yves ;
Bessou, Jean-Paul ;
Eltchaninoff, Helene .
AMERICAN JOURNAL OF CARDIOLOGY, 2011, 108 (06) :873-881
[8]   Incidence, risk factors, clinical impact, and management of bioprosthesis structural valve degeneration [J].
Cote, Nancy ;
Pibarot, Philippe ;
Clavel, Marie-Annick .
CURRENT OPINION IN CARDIOLOGY, 2017, 32 (02) :123-129
[9]   Pulsatile Distention of the Nondiseased and Stenotic Aortic Valve Annulus: Analysis With Electrocardiogram-Gated Computed Tomography [J].
de Heer, Linda M. ;
Budde, Ricardo P. J. ;
van Prehn, Joffrey ;
Mali, Willem P. Th M. ;
Bartels, Lambertus W. ;
Stella, Pieter R. ;
van Herwerden, Lex A. ;
Kluin, Jolanda ;
Vincken, Koen L. .
ANNALS OF THORACIC SURGERY, 2012, 93 (02) :516-522
[10]   Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function [J].
Delgado, Victoria ;
Ng, Arnold C. T. ;
van de Veire, Nico R. ;
van der Kley, Frank ;
Schuijf, Joanne D. ;
Tops, Laurens F. ;
de Weger, Arend ;
Tavilla, Giuseppe ;
de Roos, Albert ;
Kroft, Lucia J. ;
Schalij, Martin J. ;
Bax, Jeroen J. .
EUROPEAN HEART JOURNAL, 2010, 31 (09) :1114-1123