Surface and transverse morphology of micrometer nickel columns fabricated by localized electrochemical deposition

被引:26
作者
Chang, T. K.
Lin, J. C.
Yang, J. H.
Yeh, P. C.
Lee, D. L.
Jiang, S. B.
机构
[1] Natl Cent Univ, Inst Mat Sci & Engn, Jhongli 320, Taoyuan County, Taiwan
[2] Natl Cent Univ, Dept Mech Engn, Jhongli 320, Taoyuan County, Taiwan
[3] Natl Cent Univ, Inst Optomechatron, Jhongli 320, Taoyuan County, Taiwan
关键词
D O I
10.1088/0960-1317/17/11/022
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Micrometer nickel columns were fabricated locally on a copper substrate in a Watts bath by microanode guided electroplating which is commonly known as localized electrochemical deposition (LECD). A microanode of platinum (125 mu m in diameter) served to move up intermittently, thus guiding the growth of Ni deposit from the substrate. The separation between the microanode and top of the microcolumn was initially set at 10 mu m before setting out the electroplating. The electroplating current and local potential near the local region after the LECD were monitored and examined in this work. Surface and transverse morphology of the microcolumns were examined through a scanning electron microscope. LECD performed at biases less than 3.56 +/- 0.01 V led to columns with smooth surfaces and circular internal transverse fully compacted, whereas when performed at biases higher than 3.56 +/- 0.01 V it led to columns with a rough surface and distorted circular internal transverse with porosity in the center. The higher the bias, the worse the surface smoothness. The less circular the transverse, the less compactness in the transverse center. A compromise between the estimated supplying rate and the consumption rate of the nickel ions in the local region after the LECD is discussed to understand the dependence of the morphologies on the biases.
引用
收藏
页码:2336 / 2343
页数:8
相关论文
共 23 条
[1]  
BARD AJ, ELECTROCHEMICAL METH, P29
[2]  
Choo J. H., 2001, Proceedings of the SPIE - The International Society for Optical Engineering, V4236, P260, DOI 10.1117/12.418765
[3]  
Choo JH, 2004, MICROSYST TECHNOL, V10, P127, DOI 10.1007/S00542-003-0305-z
[4]   Localized electrochemical deposition of copper microstructures [J].
El-Giar, EM ;
Said, RA ;
Bridges, GE ;
Thomson, DJ .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2000, 147 (02) :586-591
[5]   Localized electrochemical plating of interconnectors for microelectronics [J].
ElGiar, EM ;
Thomson, DJ .
IEEE WESCANEX 97 COMMUNICATIONS, POWER AND COMPUTING CONFERENCE PROCEEDINGS, 1997, :327-332
[6]  
Hunter W., 1997, Patent No. [005641391A, 005641391]
[7]   New micro stereo lithography for freely movable 3D micro structure - Super IH process with submicron resolution [J].
Ikuta, K ;
Maruo, S ;
Kojima, S .
MICRO ELECTRO MECHANICAL SYSTEMS - IEEE ELEVENTH ANNUAL INTERNATIONAL WORKSHOP PROCEEDINGS, 1998, :290-295
[8]   High resolution 3D microstructures made by localized electrodeposition of nickel [J].
Jansson, A ;
Thornell, G ;
Johansson, S .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2000, 147 (05) :1810-1817
[9]  
JONES DA, PRINCIPLES PREVENTIO, P44
[10]   Improved copper microcolumn fabricated by localized electrochemical deposition [J].
Lin, CS ;
Lee, CY ;
Yang, JH ;
Huang, YS .
ELECTROCHEMICAL AND SOLID STATE LETTERS, 2005, 8 (09) :C125-C129