Fluorozirconate-based glass ceramic X-ray detectors for digital radiography

被引:20
|
作者
Schweizer, Stefan
Johnson, Jacqueline A.
机构
[1] Argonne Natl Lab, Nucl Engn Div, Argonne, IL 60439 USA
[2] Univ Gesamthsch Paderborn, Dept Phys, D-33098 Paderborn, Germany
基金
美国国家卫生研究院;
关键词
glass ceramics; nanoparticles; storage phosphor; scintillator;
D O I
10.1016/j.radmeas.2007.01.056
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Two-dimensional indirect digital X-ray detectors use either a storage phosphor or a scintillator as an imaging plate. A storage phosphor forms a latent X-ray image, which is subsequently readout by a photostimulable luminescence process. A scintillator produces a visible image during X-ray illumination. Commercial storage-phosphor image plates have relatively poor spatial resolution because of light scattering during the readout. To improve their image resolution, europium (II)-doped fluorozirconate (FZ)-based glasses containing barium chloride nanoparticles have been developed. X-ray imaging showed that these storage-phosphor plates can resolve features as small as 17 mu m. By using appropriate thermal-processing conditions, the FZ-based glass ceramics can also be made into transparent glass ceramic scintillators. Imaging tests showed that these scintillators have a spatial resolution and efficiency comparable to those of a single-crystal CdWO4 scintillator. These results demonstrate that FZ-based glass ceramics are good candidates for digital radiography, either for storage phosphor or scintillator applications. (C) 2007 Published by Elsevier Ltd.
引用
收藏
页码:632 / 637
页数:6
相关论文
共 50 条
  • [41] A comparative study of digital x-ray software and detectors
    Prompalit, Sakunrat
    Sinsuebphon, Nattawut
    Thanasupsombat, Chalinee
    Thongvigitmanee, Saowapak
    13TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2021), 2018,
  • [42] Monitoring of quantum efficiency of digital x-ray detectors based on photostimulated luminophores
    Zelikman M.I.
    Kabanov S.P.
    Kruchinin S.A.
    Lobov D.P.
    Biomedical Engineering, 2008, 42 (5) : 249 - 252
  • [43] Experimental evaluation of a-Se and CdTe flat-panel X-ray detectors for digital radiography and fluoroscopy
    Adachi, S
    Hori, N
    Sato, K
    Tokuda, S
    Sato, T
    Uehara, K
    Izumi, Y
    Nagata, H
    Yoshimura, Y
    Yamada, S
    MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 : 38 - 47
  • [44] Development and evaluation of a-Se and CdTe flat-panel X-ray detectors for digital radiography and fluoroscopy
    Adachi, S
    Sato, K
    Uehara, K
    Izumi, Y
    Nagata, H
    Yamada, S
    RADIOLOGY, 1999, 213P : 234 - 234
  • [45] Evaluation of the performance of digital x-ray systems in pelvis radiography
    Jreije, Antonio
    Krynke, Leonid
    Griciene, Birute
    Rimkus, Bernardas
    Dementaviciene, Jurate
    Skovorodko, Kirill
    JOURNAL OF RADIOLOGICAL PROTECTION, 2024, 44 (03)
  • [46] Scattering and its correction techniques for x-ray digital radiography
    Lu, XZ
    Chen, SY
    Lu, HN
    ISTM/99: 3RD INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, 1999, : 66 - 69
  • [47] TECHNICAL HIGHLIGHTS FOR NDT DIGITAL RADIOGRAPHY (X-RAY) INSPECTION
    Pincu, R.
    Pick, L.
    Kleinberger, O.
    10TH EUROPEAN CONFERENCE ON NON-DESTRUCTIVE TESTING 2010 (ECNDT), VOLS 1-5, 2010, : 1021 - 1026
  • [48] X-RAY RADIOGRAPHY WITH X-RAY DIFFRACTION EQUIPMENT
    CLIFTON, HE
    JOURNAL OF SEDIMENTARY PETROLOGY, 1966, 36 (02): : 620 - &
  • [49] DQE and SNR of x-ray capillary optics in digital radiography
    Bradford, CD
    Peppler, WW
    RADIOLOGY, 2000, 217 : 313 - 314
  • [50] EVALUATION OF ELEMENTAL AND COMPOUND SEMICONDUCTORS FOR X-RAY DIGITAL RADIOGRAPHY
    BENCIVELLI, W
    BERTOLUCCI, E
    BOTTIGLI, U
    DELGUERRA, A
    MESSINEO, A
    NELSON, WR
    RANDACCIO, P
    ROSSO, V
    RUSSO, P
    STEFANINI, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2): : 210 - 214