Fluorozirconate-based glass ceramic X-ray detectors for digital radiography

被引:20
|
作者
Schweizer, Stefan
Johnson, Jacqueline A.
机构
[1] Argonne Natl Lab, Nucl Engn Div, Argonne, IL 60439 USA
[2] Univ Gesamthsch Paderborn, Dept Phys, D-33098 Paderborn, Germany
基金
美国国家卫生研究院;
关键词
glass ceramics; nanoparticles; storage phosphor; scintillator;
D O I
10.1016/j.radmeas.2007.01.056
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Two-dimensional indirect digital X-ray detectors use either a storage phosphor or a scintillator as an imaging plate. A storage phosphor forms a latent X-ray image, which is subsequently readout by a photostimulable luminescence process. A scintillator produces a visible image during X-ray illumination. Commercial storage-phosphor image plates have relatively poor spatial resolution because of light scattering during the readout. To improve their image resolution, europium (II)-doped fluorozirconate (FZ)-based glasses containing barium chloride nanoparticles have been developed. X-ray imaging showed that these storage-phosphor plates can resolve features as small as 17 mu m. By using appropriate thermal-processing conditions, the FZ-based glass ceramics can also be made into transparent glass ceramic scintillators. Imaging tests showed that these scintillators have a spatial resolution and efficiency comparable to those of a single-crystal CdWO4 scintillator. These results demonstrate that FZ-based glass ceramics are good candidates for digital radiography, either for storage phosphor or scintillator applications. (C) 2007 Published by Elsevier Ltd.
引用
收藏
页码:632 / 637
页数:6
相关论文
共 50 条
  • [21] A new X-ray scintillator for digital radiography
    Nagarkar, VV
    Tipnis, SV
    Miller, SR
    Lempicki, A
    Brecher, C
    Szupryczynski, P
    Lingertat, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (03) : 297 - 300
  • [22] A new x-ray scintillator for digital radiography
    Nagarkar, VV
    Tipnis, SV
    Miller, SR
    Lempicki, A
    Brecher, C
    Szupryczynski, P
    Lingertat, H
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 134 - 137
  • [23] X-RAY PHOTOEMISSION-STUDY OF FLUOROZIRCONATE GLASS AND RELATED CRYSTALS
    ALMEIDA, RM
    LAU, J
    MACKENZIE, JD
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 1984, 69 (01) : 161 - 165
  • [24] X-ray detection properties of polycrystalline Cd1-xZnxTe detectors for digital radiography
    Kang, SS
    Park, JK
    Lee, DG
    Mun, CW
    Kim, JH
    Nam, SH
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 853 - 860
  • [25] Recent developments on a CdTe based X-ray detector for digital radiography
    Glasser, F
    Martin, JL
    Thevenin, B
    Schermesser, P
    Pantigny, P
    Laurent, JY
    Rambaud, P
    Pitault, B
    Paltrier, S
    PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 513 - 519
  • [26] Multipurpose digital X-Ray image detectors
    Veip Y.A.
    Mazurov A.I.
    Biomedical Engineering, 2009, 43 (5) : 231 - 233
  • [27] X-ray radiography of HPGe detectors for Monte Carlo simulations
    Pohuliai, Serhii
    Vlasenko, Andrey
    Malgin, Vladislav
    Kanapelka, Marina
    APPLIED RADIATION AND ISOTOPES, 2023, 198
  • [28] Multifunctional digital x-ray image detectors
    Zhlobinskaya S.V.
    Morgun O.N.
    Nemchenko K.E.
    Biomedical Engineering, 2008, 42 (5) : 256 - 260
  • [29] Scintillating glass-ceramic substrates for indirect flat panel detectors in digital radiography
    Leonard, Russell L.
    Berkowitz, Danielle T.
    Thomas, Austin
    Howansky, Adrian
    Lubinsky, Anthony R.
    Johnson, Jacqueline A.
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2020, 103 (12) : 6893 - 6900
  • [30] Digital X-ray Radiogrammetry versus radiography as predictors
    Hoff, Mari
    SCANDINAVIAN JOURNAL OF RHEUMATOLOGY, 2010, 39 : 13 - 13