Periimplant Bone Response in Human- Retrieved, Clinically Stable, Successful, and Functioning Dental Implants After a Long-Term Loading Period: A Report of 17 Cases From 4 to 20 Years

被引:19
作者
Iezzi, Giovanna [1 ]
Piattelli, Adriano [2 ]
Mangano, Carlo
Degidi, Marco
Testori, Tiziano [3 ]
Vantaggiato, Giovanni
Fiera, Elisabetta
Frosecchi, Massimo
Floris, Pierluigi
Perroni, Roberto
Ravera, Lorenzo
Gomez Moreno, Gerardo [4 ]
De Martinis, Emanuele
Perrotti, Vittoria [1 ,5 ]
机构
[1] Univ G dAnnunzio, Dept Med Oral & Biotechnol Sci, Chieti, Italy
[2] Univ G dAnnunzio, Dept Med Oral & Biotechnol Sci, Oral Pathol & Med, Chieti, Italy
[3] Univ Milan, Sch Dent, Dept Biomed Surg & Dent Sci, Sect Implant Dent & Oral Rehabil,IRCCS Galeazzi I, Milan, Italy
[4] Univ Granada, Fac Dent, Pharmacol Res Dent, Dept Special Care Dent, Granada, Spain
[5] Univ G dAnnunzio, Sch Dent, Chieti, Italy
关键词
bone-to-implant contact; histomorphometry; osseointegration; removed implants; ROOT-FORM IMPLANTS; SUBANTRAL AUGMENTATION PROCEDURE; SCANNING-ELECTRON-MICROSCOPY; HISTOLOGIC EVALUATION; HISTOMORPHOMETRIC EVALUATION; OSSEOINTEGRATION; TITANIUM; CONJUNCTION; INTERFACE; TISSUES;
D O I
10.1097/ID.0000000000000415
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: This study aimed at a histologic and histomorphometric analysis of the periimplant tissues and bone-titanium interface reactions in successfully osseointegrated, clinically stable, and immobile human titanium dental implants retrieved after a long loading period. Materials and Methods: In the last 30 months (2013-2015), 21 implants, retrieved from individuals for different causes after a loading period ranging from 4 to 20 years, were sent to the Implant Retrieval Center, University of Chieti-Pescara, Italy. In 4 cases, almost all the bone had been lost during the retrieval, whereas in the remaining 17 cases, mineralized bone was still present. Results: Around the majority of the implants, mature compact bone with few marrow spaces was found. The trabecular bone, constituted by a few thin bone trabeculae, was in a periimplant location around only a few implants. A high percentage of bone-implant contact (BIC) (comprised between 32 +/- 4.1% and 83 +/- 2.9%) was present. In almost all implants, the space within the threads was almost completely filled by compact lamellar bone or by a thin layer of bone. Close and tight contact between bone and implant surface was observed in all specimens with no gaps or connective tissue at the interface. Conclusions: All implants appeared to be well integrated in the surrounding mineralized bone, and all of them showed adequate boneto- implant contact percentages.
引用
收藏
页码:380 / 386
页数:7
相关论文
共 38 条
[1]   Human cadaveric histomorphological and metallurgical analysis of dental implants following 12.5 years of service [J].
Abbott, John R. ;
Marino, Victor ;
Bartold, P. Mark .
CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (02) :266-271
[2]  
Albrektsson T, 1993, CLIN MAT, V122, P1
[3]  
Coelho Paulo G, 2010, J Long Term Eff Med Implants, V20, P335
[4]  
Degidi Marco, 2005, J Oral Implantol, V31, P18
[5]  
Di Stefano Danilo, 2006, J Oral Implantol, V32, P171
[6]   Progressive plateau root form dental implant osseointegration: A human retrieval study [J].
Gil, Luiz F. ;
Suzuki, Marcelo ;
Janal, Malvin N. ;
Tovar, Nick ;
Marin, Charles ;
Granato, Rodrigo ;
Bonfante, Estevam A. ;
Jimbo, Ryo ;
Gil, Jose N. ;
Coelho, Paulo G. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2015, 103 (06) :1328-1332
[7]   POSTMORTEM EXAMINATION OF 6 MAXILLARY CORE-VENT IMPLANTS - REPORT OF A CASE [J].
GORES, RJ ;
HAYES, CK ;
UNNI, KK .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1989, 47 (03) :302-306
[8]  
Iezzi Giovanna, 2005, J Oral Implantol, V31, P225, DOI 10.1563/1548-1336(2005)31[225:BRTSUI]2.0.CO
[9]  
2
[10]  
Iezzi G, 2012, J OSSEOINTEGRATION, V4, P39