Adherence of self-monitoring of blood glucose in persons with type 1 diabetes in Sweden

被引:75
作者
Mostrom, Peter [1 ]
Ahlen, Elsa [2 ,3 ,4 ]
Imberg, Henrik [5 ,6 ,7 ]
Hansson, Per-Olof [4 ]
Lind, Marcus [3 ,4 ]
机构
[1] Alingsas Lasarett, Dept Internal Med, Alingsas, Sweden
[2] Varnamo Hosp, Dept Med, Varnamo, Sweden
[3] NU Hosp Grp, Dept Med, Uddevalla, Sweden
[4] Univ Gothenburg, Sahlgrenska Acad, Inst Med, Dept Mol & Clin Med, Gothenburg, Sweden
[5] Stat Konsultgrp, Gothenburg, Sweden
[6] Chalmers Univ Technol, Dept Math Sci, Gothenburg, Sweden
[7] Univ Gothenburg, Gothenburg, Sweden
关键词
INSULIN-PUMP THERAPY; GLYCEMIC CONTROL; FREQUENCY; MELLITUS; SMBG;
D O I
10.1136/bmjdrc-2016-000342
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The primary aim was to evaluate the extent to which persons with type 1 diabetes perform self-monitoring of blood glucose (SMBG) according to guidelines. Secondary objectives were to investigate predictors for good SMBG adherence, reasons for non-adherence, and association between SMBG frequency and hemoglobin A1c (HbA1c). Methods: This was a survey-based cross-sectional study. Questionnaires were sent out to 600 random patients at five sites. Patients were included if they were diagnosed with type 1 diabetes and >= 18 years old and excluded if they were currently using continuous glucose monitoring (CGM). Analysis of data was performed separately for the three sites where the answer frequency was >= 70%. Results: In total, 138 of 314 study participants, 43.9% (95% CI 38.5% to 49.4%) performed SMBG >= 4 times per day. For the three clinics where >= 70% of surveyed patients were included in the analysis, results were similar, 41.3% (95% CI 34.7% to 47.8%). Top three reported reasons for not performing more frequent SMBG were lack of time, not remembering, and self-consciousness. Frequency of SMBG was associated with HbA1c levels (p<0.0001). 30% of patients believed that <= 3 SMBG/day was recommended by healthcare providers. Conclusions: Less than 50% of patients in Sweden follow guidelines of SMBG >= 4 times per day, despite glucose meters and strips being generally available at no cost. This indicates a need for further support in performing SMBG and increased availability of other tools for glucose monitoring.
引用
收藏
页数:9
相关论文
共 27 条
[1]  
Ahlen Elsa, 2016, J Diabetes Sci Technol, V10, P1006, DOI 10.1177/1932296816652901
[2]   Standards of Medical Care in Diabetes-2014 [J].
不详 .
DIABETES CARE, 2014, 37 :S14-S80
[3]  
[Anonymous], EGENMATNING BLODGLUK
[4]  
[Anonymous], VAGLEDNING UPPHANDLI
[5]   Factors associated with adherence to self-monitoring of blood glucose among persons with diabetes [J].
Barner, JC ;
Lopez, D .
DIABETES EDUCATOR, 2004, 30 (01) :112-125
[6]   Effect of Continuous Glucose Monitoring on Hypoglycemia in Type 1 Diabetes [J].
Battelino, Tadej ;
Phillip, Moshe ;
Bratina, Natasa ;
Nimri, Revital ;
Oskarsson, Per ;
Bolinder, Jan .
DIABETES CARE, 2011, 34 (04) :795-800
[7]   Psychological and pharmacological interventions for depression in patients with diabetes mellitus: an abridged Cochrane review [J].
Baumeister, H. ;
Hutter, N. ;
Bengel, J. .
DIABETIC MEDICINE, 2014, 31 (07) :773-786
[8]   Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes [J].
Bergenstal, Richard M. ;
Tamborlane, William V. ;
Ahmann, Andrew ;
Buse, John B. ;
Dailey, George ;
Davis, Stephen N. ;
Joyce, Carol ;
Peoples, Tim ;
Perkins, Bruce A. ;
Welsh, John B. ;
Willi, Steven M. ;
Wood, Michael A. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (04) :311-320
[9]  
Breton Marc D, 2010, J Diabetes Sci Technol, V4, P562
[10]   Do diabetes mellitus patients adhere to self-monitoring of blood glucose (SMBG) and is this associated with glycemic control? Experiences from a SMBG program in western Kenya [J].
Charity, K. Wambui ;
Kumar, Ajay M. V. ;
Hinderaker, Sven Gudmund ;
Chinnakali, Palanivel ;
Pastakia, Sonak D. ;
Kamano, Jemimah .
DIABETES RESEARCH AND CLINICAL PRACTICE, 2016, 112 :37-43