Ultrasound-Enhanced Transcorneal Drug Delivery for Treatment of Fungal Keratitis
被引:3
|
作者:
Allison, Claire
论文数: 0引用数: 0
h-index: 0
机构:
George Washington Univ, Dept Biomed Engn, 800 22nd St NW,Rm 6670, Washington, DC 20052 USAGeorge Washington Univ, Dept Biomed Engn, 800 22nd St NW,Rm 6670, Washington, DC 20052 USA
Allison, Claire
[1
]
Cellum, Blake
论文数: 0引用数: 0
h-index: 0
机构:
George Washington Univ, Dept Biomed Engn, 800 22nd St NW,Rm 6670, Washington, DC 20052 USAGeorge Washington Univ, Dept Biomed Engn, 800 22nd St NW,Rm 6670, Washington, DC 20052 USA
Cellum, Blake
[1
]
Karpinecz, Bianca
论文数: 0引用数: 0
h-index: 0
机构:
George Washington Univ, Dept Biomed Engn, 800 22nd St NW,Rm 6670, Washington, DC 20052 USAGeorge Washington Univ, Dept Biomed Engn, 800 22nd St NW,Rm 6670, Washington, DC 20052 USA
Karpinecz, Bianca
[1
]
Nasrallah, Fadi
论文数: 0引用数: 0
h-index: 0
机构:
Retina Consultants, Washington, DC USAGeorge Washington Univ, Dept Biomed Engn, 800 22nd St NW,Rm 6670, Washington, DC 20052 USA
Nasrallah, Fadi
[2
]
论文数: 引用数:
h-index:
机构:
Zderic, Vesna
[1
]
机构:
[1] George Washington Univ, Dept Biomed Engn, 800 22nd St NW,Rm 6670, Washington, DC 20052 USA
Purpose: Transcorneal drug delivery is hindered by ocular physical and biochemical properties, such as tear production, the epithelial layer of the cornea, and blinking. The aim of this study was to determine whether ultrasound can be applied to increase the transcorneal drug delivery of natamycin used in the treatment of fungal keratitis without dangerously overheating the surrounding ocular tissues. Methods: To verify the safety of various sets of ultrasound parameters, modeling studies were conducted using OnScale, an ultrasonic wave modeling software. Ultrasound parameters determined optimal for ocular tissue safety were used in a laboratory setting in a jacketed Franz diffusion cell setup. Histological images of the cross-section of the corneas used in experiments were examined for cell damage under a microscope. Results: Increases in transcorneal drug delivery were seen in every treatment parameter combination when compared with the sham treatment. The highest increase was 4.0 times for 5 minutes of pulsed ultrasound at a 25% duty cycle and a frequency of 400 kHz and an intensity of 0.5 W/cm(2) with statistical significance (P < 0.001). Histological analysis revealed structural damage only in the corneal epithelium, with most damage being at the epithelial surface. Conclusions: This study suggests that ultrasound is a safe, effective, and minimally invasive treatment method for enhancing the transcorneal drug delivery of natamycin. Further research is needed into the long-term effects of ultrasound parameters used in this study on human ocular tissues.