Automatic motion estimation using flow parameters for dynamic contrast-enhanced ultrasound

被引:3
作者
Barrois, Guillaume [1 ,2 ]
Coron, Alain [1 ,2 ]
Lucidarme, Olivier [1 ,2 ,3 ]
Bridal, S. Lori [1 ,2 ]
机构
[1] Univ Paris 06, Sorbonne Univ, Lab Imagerie Biomed, INSERM,U1146,UMR, F-75005 Paris, France
[2] CNRS, UMR7371, F-75005 Paris, France
[3] Grp Hosp Pitie Salpetriere, Serv Radiol Polyvalente & Oncol, F-75634 Paris, France
关键词
motion compensation; contrast-enhanced imaging; flow quantification; ultrasound; microbubbles; BLOOD-FLOW; REGISTRATION; PERFUSION; MODEL; LOCALIZATION; SEQUENCES; US;
D O I
10.1088/0031-9155/60/6/2117
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dynamic contrast-enhanced ultrasound (DCE-US) sequences are subject to motion which can disturb functional flow quantification. This can make estimated parameters more variable or unreliable. Methods that compensate for motion are therefore desirable. The most commonly used motion correction techniques in DCE-US register the images in the sequence with respect to a user-selected reference image. However, this image may not include all features that are representative of the whole sequence. Moreover, image-based registration neglects pertinent, functional-flow information contained in the DCE-US sequence. An operator-free method is proposed that combines the motion estimation and flow-parameter quantification (M/Q method) in a single mathematical framework. This method is based on a realistic multiplicative model of the DCE-US noise. By computing likelihood in this model, motion and flow parameters are both estimated iteratively. First, the maximization is accomplished by estimating functional and motion parameters. Then, a final registration based on a non-parametric temporal smoothing of the sequence is performed. This method is compared to a conventional (mutual information) registration method where all the images of the sequence are registered with respect to a reference image chosen by an expert. The two methods are evaluated on simulated sequences and DCE-US sequences acquired in patients (N = 15). The M/Q method demonstrates significantly (p < 0.05) lower Dice coefficients and Hausdorff distance than the conventional method on the simulated data sets. On the in vivo sequences analysed, the M/Q methods outperformed the conventional method in terms of mean Dice and Hausdorff distance on 80% of the sequences, and in terms of standard deviation of Dice and Hausdorff distance on 87% of the sequences.
引用
收藏
页码:2117 / 2133
页数:17
相关论文
共 33 条
  • [1] Model-based registration for dynamic cardiac perfusion MRI
    Adluru, Ganesh
    DiBella, Edward V. R.
    Schabel, Matthias C.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (05) : 1062 - 1070
  • [2] [Anonymous], 2006, P 8 C AC TOURS FRANC
  • [3] Simulation of dynamic contrast-enhanced ultrasound sequences using example-based texture generation
    Barrois, G.
    Coron, A.
    Bridal, S. L.
    [J]. IRBM, 2014, 35 (05) : 233 - 243
  • [4] A Multiplicative Model for Improving Microvascular Flow Estimation in Dynamic Contrast-Enhanced Ultrasound (DCE-US): Theory and Experimental Validation
    Barrois, Guillaume
    Coron, Alain
    Payen, Thomas
    Dizeux, Alexandre
    Bridal, Lori
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (11) : 2284 - 2294
  • [5] Bhushan M, 2011, LECT NOTES COMPUT SC, V6891, P476, DOI 10.1007/978-3-642-23623-5_60
  • [6] Dual-mode registration of dynamic contrast-enhanced ultrasound combining tissue and contrast sequences
    Bouhlel, Nizar
    Coron, Alain
    Barrois, Guillaume
    Lucidarme, Olivier
    Bridal, S. Lori
    [J]. ULTRASONICS, 2014, 54 (05) : 1289 - 1299
  • [7] Tracer kinetic model-driven registration for dynamic contrast-enhanced MRI time-series data
    Buonaccorsi, Giovanni A.
    O'Connor, James P. B.
    Caunce, Angela
    Roberts, Caleb
    Cheung, Sue
    Watson, Yvonne
    Davies, Karen
    Hope, Lynn
    Jackson, Alan
    Jayson, Gordon C.
    Parker, Geoffrey J. M.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (05) : 1010 - 1019
  • [8] Automatic Respiratory Gating for Contrast Ultrasound Evaluation of Liver Lesions
    Christofides, Damianos
    Leen, Edward
    Averkiou, Michalakis A.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (01) : 25 - 32
  • [9] ULTRASOUND SCATTERING PROPERTIES OF ALBUNEX MICROSPHERES
    DEJONG, N
    HOFF, L
    [J]. ULTRASONICS, 1993, 31 (03) : 175 - 181
  • [10] Quantitative microbubble enhanced transrectal ultrasound as a tool for monitoring hormonal treatment of prostate carcinoma
    Eckersley, RJ
    Sedelaar, JPM
    Blomley, MJK
    Wijkstra, H
    deSouza, NM
    Cosgrove, DO
    de la Rosette, JJMCH
    [J]. PROSTATE, 2002, 51 (04) : 256 - 267