Safety Margin Assessment After Radiofrequency Ablation of the Liver Using Registration of Preprocedure and Postprocedure CT Images

被引:79
作者
Kim, Kyung Won [1 ,2 ]
Lee, Jeong Min [1 ,2 ]
Klotz, Ernst [3 ]
Kim, Soo Jin [1 ,2 ]
Kim, Se Hyung [1 ,2 ]
Kim, Ji Young [1 ,2 ]
Han, Joon Koo [1 ,2 ]
Choi, Byung Ihn [1 ,2 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Inst Radiat Med, Seoul 110744, South Korea
[3] Siemens Healthcare, CT Div, Forchheim, Germany
基金
新加坡国家研究基金会;
关键词
CT; liver; radiofrequency ablation (RFA); registration; safety margin; TUMOR; FEASIBILITY; PET;
D O I
10.2214/AJR.10.5122
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to evaluate a new technique for registration of postprocedure to preprocedure CT images to determine the effect on the safety margin assessment after radiofrequency ablation (RFA). MATERIALS AND METHODS. Registration of post-RFA CT to pre-RFA CT images was performed using prototype software via nonrigid registration in 31 patients with hepatocellular carcinoma who were treated with RFA. Registration accuracy was validated by setting pairs of corresponding landmarks on registered post-RFA CT and pre-RFA CT images and by calculating the mean difference between the corresponding landmarks. Three radiologists independently conducted a retrospective review of the pre-RFA and post-RFA CT images for safety margin assessment with and without registered images. The safety margin was rated using a 4-point scale (1, residual tumor; 2, < 2 mm safety margin; 3, 2 to < 5 mm safety margin; and 4, >= 5 mm safety margin). Interobserver agreement was evaluated using the weighted kappa test. RESULTS. The mean difference between the corresponding landmarks was 1.3 mm, thus suggesting accurate registration. A more accurate correlation between the degree of the reader safety margin and the reference value was obtained from pre-RFA and post-RFA CT images using registered CT images than without using registered images (gamma, 0.918 vs 0.887 for reader 1, 0.888 vs 0.651 for reader 2, and 0.811 vs 0.497 for reader 3, respectively). Interobserver agreement (kappa) increased from 0.503-0.558 in the first session without registered images to 0.807-0.869 in the second session with registered CT images. CONCLUSION. Registration of post-RFA CT to pre-RFA CT images is an accurate and useful technique for assessing the safety margin immediately after RFA.
引用
收藏
页码:W565 / W572
页数:8
相关论文
共 16 条
  • [1] Evaluation of liver metastases after radiofrequency ablation:: Utility of 18F-FDG PET and PET/CT
    Barker, DW
    Zagoria, RJ
    Morton, KA
    Kavanagh, PV
    Shen, P
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 1096 - 1102
  • [2] Feasibility of a novel deformable image registration technique to facilitate classification, targeting, and monitoring of tumor and normal tissue
    Brock, KK
    Dawson, LA
    Sharpe, MB
    Moseley, DJ
    Jaffray, DA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (04): : 1245 - 1254
  • [3] Management of hepatoceullular carcinoma
    Bruix, J
    Sherman, M
    [J]. HEPATOLOGY, 2005, 42 (05) : 1208 - 1236
  • [4] Chefd'hotel C, 2002, 2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, P753
  • [5] Radiofrequency ablation of liver tumours: systematic review
    Decadt, B
    Siriwardena, AK
    [J]. LANCET ONCOLOGY, 2004, 5 (09) : 550 - 560
  • [6] A feasibility study: Evaluation of radiofrequency ablation therapy to hepatocellular carcinoma using image registration of preoperative and postoperative CT
    Fujioka, Chikako
    Horiguchi, Jun
    Ishifuro, Minoru
    Kakizawa, Hideaki
    Kiguchi, Masao
    Matsuura, Noriaki
    Hieda, Masashi
    Tachikake, Toshihiro
    Alam, Farzana
    Furukawa, Takashi
    Ito, Katsuhide
    [J]. ACADEMIC RADIOLOGY, 2006, 13 (08) : 986 - 994
  • [7] Giesel F. L., 2009, Experimental Oncology, V31, P106
  • [8] Image-guided tumor ablation: Standardization of terminology and reporting criteria
    Goldberg, SN
    Grassi, CJ
    Cardella, JF
    Charboneau, JW
    Dodd, GD
    Dupuy, DE
    Gervais, D
    Gillams, AR
    Kane, RA
    Lee, FT
    Livraghi, T
    McGahan, J
    Phillips, DA
    Rhim, H
    Silverman, SG
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 16 (06) : 765 - 778
  • [9] Algorithms for radiological image registration and their clinical application
    Hawkes, DJ
    [J]. JOURNAL OF ANATOMY, 1998, 193 : 347 - 361
  • [10] Quantitative CT Color Mapping of the Arterial Enhancement Fraction of the Liver to Detect Hepatocellular Carcinoma
    Kim, Kyung Won
    Lee, Jeong Min
    Klotz, Ernst
    Park, Hee Sun
    Lee, Dong Ho
    Kim, Ji Young
    Kim, Soo Jin
    Kim, Se Hyung
    Lee, Jae Young
    Han, Joon Koo
    Choi, Byung Ihn
    [J]. RADIOLOGY, 2009, 250 (02) : 425 - 434