Investigation of changes in optical attenuation of bone and neuronal cells in organ culture or three-dimensional constructs in vitro with optical coherence tomography: relevance to cytochrome oxidase monitoring

被引:32
作者
Xu, XQ [1 ]
Wang, RKK [1 ]
El Haj, A [1 ]
机构
[1] Keele Univ, N Staffordshire Hosp Trust, Sch Med, Ctr Sci & Technol Med, Stoke On Trent ST4 7QB, Staffs, England
来源
EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS | 2003年 / 32卷 / 04期
基金
英国工程与自然科学研究理事会;
关键词
absorption; cytochrome oxidase; optical coherence tomography; scattering; tissue and cells;
D O I
10.1007/s00249-003-0285-z
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Changes in optical attenuation, relevant to cytochrome oxidase, of the rat bone periosteal tissue in explanted culture and human neuronal cells in three-dimensional agarose constructs have been monitored by the use of optical coherence tomography (OCT), with potential applications in tissue engineering and diagnosis. A superluminescent diode (SLD) with a peak emission wavelength (lambda=820 nm) that is the near-infrared absorption band of the oxidized form of CytOx was employed. The attenuation coefficient was obtained from the depth-resolved reflectance profiles of liquid phantoms (naphthol green B with intralipid), explant culture (periosteum of calvaria from rats) and cells in 3D agarose constructs. The absorption coefficient of naphthol green B can be accurately quantified by the linear relationship between attenuation coefficients and the concentration. The difference in the attenuation coefficient of astrocytoma cells in agarose before and after reduction of CytOx is 0.26+/-0.10 mm(-1) (n = 9), whereas no attenuation is observed with the agarose control. Reduction of the enzyme in periosteal tissue leads to a change in attenuation coefficient of 0.43+/-0.24 mm(-1) (n = 7). For comparison, using a biochemical assay, the absorption coefficient of the oxidized-reduced form of CytOx is measured at approximately 8.3+/-1.5x10(-3) mm(-1) (n = 4) and 8.7+/-2.5x 10(-3) mm(-1) (n = 4) at 820 nm for astrocytoma cells and rat periosteum, respectively. The lower value of CytOx concentration using biochemical versus OCT measurements may result from shifts in the scattering profile and the amplifying influences of multiple heme-based oxidases, indicating that conventional OCT is not specific enough to monitor redox changes in cytochrome oxidase. However, qualitative shifts in oxidation state are apparent using the technique. Our results suggest the potential application of OCT in providing high-resolution tomographic imaging of tissues in organ culture and cells grown in three-dimensional constructs in vitro.
引用
收藏
页码:355 / 362
页数:8
相关论文
共 24 条
  • [1] CYTOCHROME-OXIDASE CONTENT OF RAT-BRAIN DURING DEVELOPMENT
    BROWN, GC
    CROMPTON, M
    WRAY, S
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA, 1991, 1057 (02) : 273 - 275
  • [2] Quantification in tissue near-infrared spectroscopy
    Delpy, DT
    Cope, M
    [J]. PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 1997, 352 (1354) : 649 - 659
  • [3] Iizuka MN, 1999, LASER SURG MED, V25, P159, DOI 10.1002/(SICI)1096-9101(1999)25:2<159::AID-LSM10>3.3.CO
  • [4] 2-M
  • [5] NONINVASIVE, INFRARED MONITORING OF CEREBRAL AND MYOCARDIAL OXYGEN SUFFICIENCY AND CIRCULATORY PARAMETERS
    JOBSIS, FF
    [J]. SCIENCE, 1977, 198 (4323) : 1264 - 1267
  • [6] KIERNAN JA, 1990, HISTOLOGICAL HISTOCH, P258
  • [7] Liu H, 1996, J Biomed Opt, V1, P200, DOI 10.1117/12.231370
  • [8] PERFORMANCE COMPARISON OF SEVERAL PUBLISHED TISSUE NEAR-INFRARED SPECTROSCOPY ALGORITHMS
    MATCHER, SJ
    ELWELL, CE
    COOPER, CE
    COPE, M
    DELPY, DT
    [J]. ANALYTICAL BIOCHEMISTRY, 1995, 227 (01) : 54 - 68
  • [9] Spectroscopic optical coherence tomography
    Morgner, U
    Drexler, W
    Kärtner, FX
    Li, XD
    Pitris, C
    Ippen, EP
    Fujimoto, JG
    [J]. OPTICS LETTERS, 2000, 25 (02) : 111 - 113
  • [10] Evaluation of optical coherence quantitation of analytes in turbid media by use of two wavelengths
    Sathyam, US
    Colston, BW
    Da Silva, LB
    Everett, MJ
    [J]. APPLIED OPTICS, 1999, 38 (10) : 2097 - 2104