Friction and wear behavior of poly(vinyl alcohol)/poly(vinyl pyrrolidone) hydrogels for articular cartilage replacement

被引:83
作者
Katta, Jayanth K.
Marcolongo, Michele
Lowman, Anthony
Mansmann, Kevin A.
机构
[1] Drexel Univ, Sch Biomed Engn, Philadelphia, PA 19104 USA
[2] Arthroscopy Res Inst, Bryn Mawr, PA 19010 USA
[3] Drexel Univ, Dept Mat Engn, Philadelphia, PA 19104 USA
[4] Drexel Univ, Dept Chem Engn, Philadelphia, PA 19104 USA
关键词
hydrogels; artificial cartilage; friction; wear-synovial fluid;
D O I
10.1002/jbm.a.31238
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Many hydrogels have been proposed as articular cartilage replacements as an alternative to partial or total joint replacements. In the current study, poly(vinyl alcohol)/poly(vinyl pyrrolidone) (PVA/PVP) hydrogels were investigated as potential cartilage replacements by investigating their in vitro wear and friction characteristics in a pin-on-disk setup. A three-factor variable-level experiment was designed to study the wear and friction characteristics of PVA/PVP hydrogels. The three different factors studied were (a) polymer content of PVA/PVP hydrogels, (b) load, and (c) effect of lubricant. Twelve tests were conducted, with each lasting 100,000 cycles against Co-Cr pins. The average coefficient of friction for synovial fluid lubrication was a low 0.035 compared with 0.1 for bovine serum lubrication. Frictional behavior of PVA/PVP hydro-gels did not follow Amonton's law of friction. Wear of the hydrogels was quantified by measuring their dry masses before and after the tests. Higher polymer content significantly reduced the wear of hydrogel samples with 15% PVA/PVP samples, showing an average dry polymer loss of 4.74% compared with 6.05% for 10% PVA/PVP samples. A trend change was observed in both the friction and wear characteristics of PVA/PVP hydrogels at 125 N load, suggesting a transition in the lubricating mechanism at the pin-hydrogel interface at the critical 125 N load. (c) 2007 Wiley Periodicals, Inc.
引用
收藏
页码:471 / 479
页数:9
相关论文
共 56 条
[21]   Development of an artificial meniscus using polyvinyl alcohol-hydrogel for early return to, and continuance of, athletic life in sportspersons with severe meniscus injury. I: mechanical evaluation [J].
Kobayashi, M ;
Toguchida, J ;
Oka, M .
KNEE, 2003, 10 (01) :47-51
[22]   Simulation of initial frontside and backside wear rates in a modular acetabular component with multiple screw holes [J].
Kurtz, SM ;
Ochoa, JA ;
Hovey, CB ;
White, CV .
JOURNAL OF BIOMECHANICS, 1999, 32 (09) :967-976
[23]  
Lozinsky VI, 1996, J APPL POLYM SCI, V61, P1991, DOI 10.1002/(SICI)1097-4628(19960912)61:11<1991::AID-APP13>3.0.CO
[24]  
2-2
[25]  
Mallapragada SK, 1997, J BIOMED MATER RES, V36, P125, DOI 10.1002/(SICI)1097-4636(199707)36:1<125::AID-JBM15>3.0.CO
[26]  
2-H
[27]  
Mallapragada SK, 1996, J POLYM SCI POL PHYS, V34, P1339, DOI 10.1002/(SICI)1099-0488(199605)34:7<1339::AID-POLB15>3.0.CO
[28]  
2-B
[29]   Physical properties of gamma irradiated poly(vinyl alcohol) hydrogel preparations [J].
Mondino, AV ;
González, ME ;
Romero, GR ;
Smolko, EE .
RADIATION PHYSICS AND CHEMISTRY, 1999, 55 (5-6) :723-726
[30]  
Mow Van C., 1997, P275