Non-contact measurement of lightning and switching transient overvoltage based on capacitive coupling and pockels effects

被引:21
作者
Han, Rui [1 ]
Yang, Qing [1 ]
Sima, Wenxia [1 ]
Zhang, Yu [2 ]
Sun, Shangpeng [1 ]
Liu, Tong [1 ]
Chen, Shaoqing [2 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400044, Peoples R China
[2] Sichuan Elect Power Res Inst, Chengdu 610072, Peoples R China
基金
中国国家自然科学基金;
关键词
Lightning overvoltage; Switching overvoltage; Non-contact measurement; Pockels effect; Stray coupling capacitor; LiNbO3; crystal; SYSTEM; DESIGN; SENSOR;
D O I
10.1016/j.epsr.2015.11.037
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Measurement of lightning and switching transient overvoltage in power system is significant to the research that guides the protection of power system. Anew type of sensor for non-contact measurement of lightning and switching transient overvoltage in power system is designed in this study. This sensor is composed of two parts, namely, voltage induction and optoelectronic conversion units. Given the existing stray coupling capacitor C-1 between the transmission line or bus bar and a metal plate placed under it, a voltage induction unit is designed by utilizing the C-1 and a capacitor with fixed value C-2 connected in series, then the high-voltage non-contact induction on a transmission line or bus bar is achieved. The optoelectronic conversion unit is designed based on the Pockels effect of the LiNbO3 crystal. The voltage signal induced by the voltage induction unit can be converted to an optical signal by the optoelectronic conversion unit for long-distance transmission through optical fibers without power supply at the monitoring site. Laboratory and field tests revealed that the new developed sensor possesses good linear region, high precision, and wide frequency band of the response to lightning and switching transient overvoltage in power system. The sensor can also be applied to the non-contact measurement of lightning and switching transient overvoltage in power system with different voltage levels by conveniently adjusting the distance between the sensor and the line. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:93 / 100
页数:8
相关论文
共 19 条
[1]   Categorization and analysis of power system transients [J].
Bollen, MHJ ;
Styvaktakis, E ;
Gu, IYH .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (03) :2298-2306
[2]   Research on a New Type of Overvoltages Monitoring Sensor and Decoupling Technology [J].
Chen, Shaoqing ;
Wang, Hanyu ;
Du, Lin ;
Li, Jianming .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2014, 24 (05)
[3]  
Dong H., 2014, THESIS
[4]  
Han R, 2014, 2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), P1147, DOI 10.1109/ICLP.2014.6973299
[5]   INTEGRATED-OPTICS POCKELS CELL HIGH-VOLTAGE SENSOR [J].
JAEGER, NAF ;
RAHMATIAN, F .
IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (01) :127-134
[6]  
Jia XF, 2002, POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, P994, DOI 10.1109/ICPST.2002.1047548
[7]  
Kiuchi K, 2012, C ELECT INSUL DIEL P, P199, DOI 10.1109/CEIDP.2012.6378755
[8]   Directly High-Voltage Measuring System Based on Pockels Effect [J].
Kumada, Akiko ;
Hidaka, Kunihiko .
IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (03) :1306-1313
[9]   Measurement of AC electric power based on dual transverse Pockels effect [J].
Li, CS ;
Cui, X ;
Yoshino, T .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2001, 50 (05) :1375-1380
[10]   Design of Closed-Loop Detection System for Optical Voltage Sensors Based on Pockels Effect [J].
Li, Hui ;
Bi, Lan ;
Wang, Rui ;
Li, Lijing ;
Lin, Zhili ;
Zhang, Chunxi .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 2013, 31 (12) :1921-1928