On-line dialysis as a sample preparation technique for ion chromatography

被引:17
作者
De Borba, BM
Brewer, JM
Camarda, J
机构
[1] Metrohm Peak, Houston, TX 77034 USA
[2] Brinkmann Instruments, Westbury, NY 11590 USA
关键词
sample preparation; dialysis; stopped-flow technique;
D O I
10.1016/S0021-9673(01)00797-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of on-line dialysis as a sample preparation technique for ion chromatography is described. A fully automated sample preparation device coupled to an ion chromatographic system for the determination of anions and cations in various matrices is presented. The method was based on stopped-flow dialysis, where the samples were continuously dialyzed for 10 min while the acceptor solution was stationary within the recipient channel. The matrices examined, without additional sample treatment, included milk, untreated wastewater, fruit juice, engine coolant, and a multivitamin tablet. The analyte recoveries for anions and cations in various matrices ranged from 87 to 106%. In addition, multiple sample injections were performed and repeatabilities were found in the range of 0.2 to 4%. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 18 条
[1]   ONLINE COMBINATION OF DIALYSIS AND COLUMN-SWITCHING LIQUID-CHROMATOGRAPHY AS A FULLY AUTOMATED SAMPLE PREPARATION TECHNIQUE FOR BIOLOGICAL SAMPLES - DETERMINATION OF NITROFURAN RESIDUES IN EDIBLE PRODUCTS [J].
AERTS, MML ;
BEEK, WMJ ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1990, 500 :453-468
[2]   Automated determination of verapamil and norverapamil in human plasma with on-line coupling of dialysis to high-performance liquid chromatography and fluorometric detection [J].
Ceccato, A ;
Chiap, P ;
Hubert, P ;
Toussaint, B ;
Crommen, J .
JOURNAL OF CHROMATOGRAPHY A, 1996, 750 (1-2) :351-360
[3]   AUTOMATED SEQUENTIAL TRACE ENRICHMENT OF DIALYSATES AND ROBOTICS - A TECHNIQUE FOR THE PREPARATION OF BIOLOGICAL SAMPLES PRIOR TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
COOPER, JDH ;
TURNELL, DC ;
GREEN, B ;
VERILLON, F .
JOURNAL OF CHROMATOGRAPHY, 1988, 456 (01) :53-69
[4]   Determination of flumequine and oxolinic acid in fortified chicken tissue using on-line dialysis and high-performance liquid chromatography with fluorescence detection [J].
Eng, GY ;
Maxwell, RJ ;
Cohen, E ;
Piotrowski, EG ;
Fiddler, W .
JOURNAL OF CHROMATOGRAPHY A, 1998, 799 (1-2) :349-354
[5]   Developments in sample preparation and separation techniques for the determination of inorganic ions by ion chromatography and capillary electrophoresis [J].
Haddad, PR ;
Doble, P ;
Macka, M .
JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) :145-177
[6]   SAMPLE CLEANUP METHODS FOR ION CHROMATOGRAPHY [J].
HADDAD, PR .
JOURNAL OF CHROMATOGRAPHY, 1989, 482 (02) :267-278
[7]   FLOW INJECTION ANALYSIS .6. DETERMINATION OF PHOSPHATE AND CHLORIDE IN BLOOD-SERUM BY DIALYSIS AND SAMPLE DILUTION [J].
HANSEN, EH ;
RUZICKA, J .
ANALYTICA CHIMICA ACTA, 1976, 87 (02) :353-363
[8]   AUTOMATED-ANALYSIS OF FREE AND TOTAL CONCENTRATIONS OF 3 ANTIEPILEPTIC DRUGS IN PLASMA WITH ONLINE DIALYSIS AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
JOHANSEN, K ;
KROGH, M ;
ANDRESEN, AT ;
CHRISTOPHERSEN, AS ;
LEHNE, G ;
RASMUSSEN, KE .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 669 (02) :281-288
[9]  
KUBAN P, 1997, ANAL CHEM, V69, P1167
[10]   On-line sample preparation techniques for ion chromatography [J].
Montgomery, RM ;
Saari-Nordhaus, R ;
Nair, LM ;
Anderson, JM .
JOURNAL OF CHROMATOGRAPHY A, 1998, 804 (1-2) :55-62