Single-magnet rotary flowmeter for liquid metals

被引:36
作者
Priede, Janis [1 ]
Buchenau, Dominique [2 ]
Gerbeth, Gunter [2 ]
机构
[1] Coventry Univ, Appl Math Res Ctr, Coventry, W Midlands, England
[2] Helmholtz Zentrum Dresden Rossendorf, MHD Dept, Dresden, Germany
关键词
FORCES;
D O I
10.1063/1.3610440
中图分类号
O59 [应用物理学];
学科分类号
摘要
We present a theory of single-magnet flowmeter for liquid metals and compare it with experimental results. The flowmeter consists of a freely rotating permanent magnet, which is magnetized perpendicularly to the axle it is mounted on. When such a magnet is placed close to a tube carrying liquid metal flow, it rotates so that the driving torque due to the eddy currents induced by the flow is balanced by the braking torque induced by the rotation itself. The equilibrium rotation rate, which varies directly with the flow velocity and inversely with the distance between the magnet and the tube, is affected neither by the electrical conductivity of the metal nor by the magnet strength. We obtain simple analytical solutions for the force and torque on slowly moving and rotating magnets due to eddy currents in a layer of infinite horizontal extent. The predicted equilibrium rotation rates qualitatively agree with the magnet rotation rate measured on a liquid sodium flow in stainless steel duct. (C) 2011 American Institute of Physics. [doi: 10.1063/1.3610440]
引用
收藏
页数:10
相关论文
共 29 条
  • [1] Abramowitz M., 1972, HDB MATH FUNCTIONS
  • [2] [Anonymous], 2009, Classical Electrodynamics
  • [3] THEORY OF INDUCED VOLTAGE ELECTROMAGNETIC FLOWMETERS
    BEVIR, MK
    [J]. JOURNAL OF FLUID MECHANICS, 1970, 43 : 577 - &
  • [4] BUCENIEKS I, 2005, P 8 INT S MAGN SUSP, P204
  • [5] Bucenieks I., 2002, P 8 INT PAM C FUND A, V1, P103
  • [6] The performance of electromagnetic flowmeters in a liquid metal two-phase flow
    Cha, JE
    Ahn, YC
    Se, KW
    Nam, HY
    Choi, JH
    Kim, MH
    [J]. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2003, 40 (10) : 744 - 753
  • [7] Velocity measurements in liquid sodium by means of ultrasound Doppler velocimetry
    Eckert, S
    Gerbeth, G
    [J]. EXPERIMENTS IN FLUIDS, 2002, 32 (05) : 542 - 546
  • [8] Eckert S, 2011, J NUCL SCI TECHNOL, V48, P490, DOI [10.3327/jnst.48.490, 10.1080/18811248.2011.9711724]
  • [9] ANALYSIS OF EDDY-CURRENT FLOWMETERS
    FENG, CC
    DEEDS, WE
    DODD, CV
    [J]. JOURNAL OF APPLIED PHYSICS, 1975, 46 (07) : 2935 - 2940
  • [10] Dry calibration of electromagnetic flowmeters based on numerical models combining multiple physical phenomena (multiphysics)
    Fu, X.
    Hu, L.
    Lee, K. M.
    Zou, J.
    Ruan, X. D.
    Yang, H. Y.
    [J]. JOURNAL OF APPLIED PHYSICS, 2010, 108 (08)