Detection of factor VIII gene mutations by high-resolution melting analysis

被引:31
作者
Laurie, Andrew D. [1 ]
Smith, Mark P. [1 ]
George, Peter M. [1 ]
机构
[1] Canterbury Hlth Labs, Dept Mol Pathol, Christchurch, New Zealand
关键词
D O I
10.1373/clinchem.2007.093781
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Single base-pair substitution mutations in the gene for coagulation factor VIII, procoagulant component (hemophilia A) (F8) account for approximately 50% of severe cases of hemophilia A (HA), and almost all moderate or mild cases. Because F8 is a large gene, mutation screening using denaturing HPLC or DNA sequencing is time-consuming and expensive. Methods: We evaluated high-resolution melting analysis as an option for screening for F8 gene mutations. The melting curves of amplicons heterozygous for known F8 gene mutations were compared with melting curves of the corresponding normal amplicons to assess whether melting analysis could detect these variants. We examined 2 platforms, the Roche LightCycler 480 (LC480) and the Idaho Technology LightScanner. Results: On both instruments, 18 (90%) of the 20 F8 gene variants we examined were resolved by melting analysis. For the other 2 mutations, the melting curves of the heterozygous amplicons were similar to the corresponding normal amplicons, suggesting these variants may not be detected by this approach in a mutation-scanning screen. Conclusion: High-resolution melting analysis is an appealing technology for F8 gene screening. It is rapid and quickly identifies mutations in the, majority of HA patients; samples in which no mutation is detected require further testing by DNA sequencing. The LC480 and LightScanner platforms performed similarly. (C) 2007 American Association for Clinical Chemistry.
引用
收藏
页码:2211 / 2214
页数:4
相关论文
共 15 条
[1]   A comparison of high-resolution melting analysis with denaturing high-performance liquid chromatography for mutation scanning - Cystic fibrosis transmembrane conductance regulator gene as a model [J].
Chou, LS ;
Lyon, E ;
Wittwer, CT .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2005, 124 (03) :330-338
[2]   Mutations in the phenflalanine hydroxylase gene identified in 95 patients with phenylketonuria using novel systems of mutation scanning and specific genotyping based upon thermal melt profiles [J].
Dobrowolski, Steven F. ;
Ellingson, Clinton ;
Coyne, Thomas ;
Grey, Jesse ;
Martin, Ranae ;
Naylor, Edwin W. ;
Koch, Richard ;
Levy, Harvey L. .
MOLECULAR GENETICS AND METABOLISM, 2007, 91 (03) :218-227
[3]   DETECTION OF MUTATIONS IN THE FACTOR-VIII GENE USING SINGLE-STRANDED CONFORMATIONAL POLYMORPHISM (SSCP) [J].
ECONOMOU, EP ;
KAZAZIAN, HH ;
ANTONARAKIS, SE .
GENOMICS, 1992, 13 (03) :909-911
[4]   Haemophilia A: From mutation analysis to new therapies [J].
Graw, J ;
Brackmann, HH ;
Oldenburg, J ;
Schneppenheim, R ;
Spannagl, M ;
Schwaab, R .
NATURE REVIEWS GENETICS, 2005, 6 (06) :488-501
[5]  
*IDAH TECHN INV, LIGHTSCANNER INSTR D
[6]  
*J HOPK U, ONL MEND INH MAN OMM
[7]   The Factor VIII Structure and Mutation Resource Site: HAMSTeRS Version 4 [J].
Kemball-Cook, G ;
Tuddenham, EGD ;
Wacey, AI .
NUCLEIC ACIDS RESEARCH, 1998, 26 (01) :216-219
[8]   Mutation scanning the GJB1 gene with high-resolution melting analysis:: Implications for mutation scanning of genes for Charcot-Marie-Tooth disease [J].
Kennerson, L. ;
Warburton, Trent ;
Nelis, Eva ;
Brewer, Megan ;
Polly, Patsie ;
De Jonghe, Peter ;
Timmerman, Vincent ;
Nicholson, Garth A. .
CLINICAL CHEMISTRY, 2007, 53 (02) :349-352
[9]   High resolution melting analysis for the rapid and sensitive detection of mutations in clinical samples:: KRAS codon 12 and 13 mutations in non-small cell lung cancer [J].
Krypuy, Michael ;
Newnham, Genni M. ;
Thomas, David M. ;
Conron, Matthew ;
Dobrovic, Alexander .
BMC CANCER, 2006, 6 (1)
[10]   The molecular aetiology of haemophilia A in a New Zealand patient group [J].
Laurie, A. D. ;
Sheen, C. R. ;
Hanrahan, V. ;
Smith, M. P. ;
George, P. M. .
HAEMOPHILIA, 2007, 13 (04) :420-427