Comparing the Effects of Additives on Protein Analysis Between Desorption Electrospray (DESI) and Electrospray Ionization (ESI)

被引:24
作者
Honarvar, Elahe [1 ]
Venter, Andre R. [1 ]
机构
[1] Western Michigan Univ, Dept Chem, Kalamazoo, MI 49008 USA
基金
美国国家科学基金会;
关键词
Ambient ionization; DESI; Desorption electrospray ionization; Protein; Ammonium bicarbonate; Electrospray; Ionization; Cytochrome c; Myoglobin; Chymotrypsinogen; INDUCED SIGNAL SUPPRESSION; MASS-SPECTROMETRY; HOFMEISTER SERIES; AMBIENT IONIZATION; MOLECULE REACTIONS; DROPLET DYNAMICS; REAL-TIME; GAS-PHASE; ION; SENSITIVITY;
D O I
10.1007/s13361-018-2058-z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
It is frequently said that DESI-MS follows a similar ionization mechanism as ESI because of similarities usually observed in their respective mass spectra. However, practical use of DESI-MS for protein analysis is limited to proteins with lower molecular weights (<25kDa) due to a mass-dependent loss in signal intensity. Here we investigated commonly used volatile acids and their ammonium salt buffers for DESI-MS analysis of protein. We noticed that, surprisingly, some additives influence the analysis differently in DESI compared to ESI. Improved signal intensities with both DESI and ESI were obtained when acetic and formic acid were added into aqueous methanol spray solvents with both DESI and ESI. On the other hand, while with ESI the addition of ammonium salts into spray solutions strongly reduced both signal and S/N, with DESI signal intensities and S/N were improved dramatically. Ammonium bicarbonate when used with DESI reduced the total amount of adduction and delivered excellent signal-to-noise ratios with high intensity; however, it also denatures protein. When native state protein mass spectra are preferred, ammonium acetate would also deliver reasonable adduct removal and improved S/N. The amount of total adduction of individual adducting species and of all species could not be correlated with differences in either solutions pH values or with proton affinities of the anions. An obvious difference between DESI and ESI mass spectrometry is the effects of protein solubility during droplet pickup (desorption), but differences in the sizes, velocities, and composition of ionizing droplets were also discussed as important factors.
引用
收藏
页码:2443 / 2455
页数:13
相关论文
共 65 条
[1]   Salt effects on the picosecond dynamics of lysozyme hydration water investigated by terahertz time-domain spectroscopy and an insight into the Hofmeister series for protein stability and solubility [J].
Aoki, Katsuyoshi ;
Shiraki, Kentaro ;
Hattori, Toshiaki .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2016, 18 (22) :15060-15069
[2]   Analysis of polar organic micropollutants in water with ion chromatography electrospray mass spectrometry [J].
Bauer, KH ;
Knepper, TP ;
Maes, A ;
Schatz, V ;
Voihsel, M .
JOURNAL OF CHROMATOGRAPHY A, 1999, 837 (1-2) :117-128
[3]   DETECTION, IDENTIFICATION AND STRUCTURAL INVESTIGATION OF BIOLOGICALLY IMPORTANT COMPOUNDS BY SECONDARY ION MASS-SPECTROMETRY [J].
BENNINGHOVEN, A ;
SICHTERMANN, WK .
ANALYTICAL CHEMISTRY, 1978, 50 (08) :1180-1184
[4]   Why forces between proteins follow different Hofmeister series for pH above and below pI [J].
Boström, M ;
Tavares, FW ;
Finet, S ;
Skouri-Panet, F ;
Tardieu, A ;
Ninham, BW .
BIOPHYSICAL CHEMISTRY, 2005, 117 (03) :217-224
[5]   Desalting protein ions in native mass spectrometry using supercharging reagents [J].
Cassou, Catherine A. ;
Williams, Evan R. .
ANALYST, 2014, 139 (19) :4810-4819
[6]   Anions in Electrothermal Supercharging of Proteins with Electrospray Ionization Follow a Reverse Hofmeister Series [J].
Cassou, Catherine A. ;
Williams, Evan R. .
ANALYTICAL CHEMISTRY, 2014, 86 (03) :1640-1647
[7]   ORIGIN AND REMOVAL OF ADDUCTS (MOLECULAR MASS = 98-U) ATTACHED TO PEPTIDE AND PROTEIN IONS IN ELECTROSPRAY IONIZATION MASS-SPECTRA [J].
CHOWDHURY, SK ;
KATTA, V ;
BEAVIS, RC ;
CHAIT, BT .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1990, 1 (05) :382-388
[8]   Effects of salt concentration on analyte response using electrospray ionization mass spectrometry [J].
Constantopoulos, TL ;
Jackson, GS ;
Enke, CG .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (07) :625-634
[9]   Ambient mass spectrometry [J].
Cooks, RG ;
Ouyang, Z ;
Takats, Z ;
Wiseman, JM .
SCIENCE, 2006, 311 (5767) :1566-1570
[10]   Simulated splashes: Elucidating the mechanism of desorption electrospray ionization mass spectrometry [J].
Costa, Anthony B. ;
Cooks, R. Graham .
CHEMICAL PHYSICS LETTERS, 2008, 464 (1-3) :1-8