Computational Fluid Dynamics of Carotid Arteries After Carotid Endarterectomy or Carotid Artery Stenting Based on Postoperative Patient-Specific Computed Tomography Angiography and Ultrasound Flow Data

被引:20
作者
Hayase, Hitoshi
Tokunaga, Koji [1 ]
Nakayama, Toshio [2 ]
Sugiu, Kenji
Nishida, Ayumi
Arimitsu, Seiji
Hishikawa, Tomohito
Ono, Shigeki
Ohta, Makoto [2 ]
Date, Isao
机构
[1] Okayama Univ, Dept Neurol Surg, Grad Sch Med Dent & Pharmaceut Sci, Kita Ku, Okayama 7008558, Japan
[2] Tohoku Univ, Inst Fluid Sci, Sendai, Miyagi 980, Japan
关键词
Carotid artery; Computational fluid dynamics; Endarterectomy; Patch angioplasty; Stent; PATCH ANGIOPLASTY; SHEAR-STRESS; PRIMARY CLOSURE; RISK-FACTOR; GEOMETRY; RUPTURE; TRIALS;
D O I
10.1227/NEU.0b013e318208f1a0
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: There are significant differences in the postoperative morphological and hemodynamic conditions of the carotid arteries between carotid artery stenting (CAS) and endarterectomy (CEA). OBJECTIVE: To compare the postoperative rheological conditions after CAS with those after CEA with patch angioplasty (patch CEA) through the use of computational fluid dynamics (CFD) based on patient-specific data. METHODS: The rheological conditions in the carotid arteries were simulated in 2 patients after CAS and in 2 patients after patch CEA by CFD calculations. Three-dimensional reconstruction of the carotid arteries was performed with the images obtained with computed tomography angiography. The streamlines and wall shear stress (WSS) were calculated by a supercomputer. Adequate boundary conditions were determined by comparing the simulation results with ultrasound flow data. RESULTS: CFD was successfully calculated for all patients. The differences between the flow velocities of ultrasound data and those of the simulation results were limited. In the streamline analysis, the maximum flow velocities in the internal carotid artery after patch CEA were around two-thirds of those after CAS. Rotational slow flow was observed in the internal carotid artery bulb after patch CEA. WSS analysis found regional low WSS near the outer wall of the bulb. High WSS was observed at the distal end of the arteriotomy after patch CEA and at the residual stenosis after CAS. CONCLUSION: CFD of postoperative carotid arteries disclosed the differences in streamlines and WSS between CAS and patch CEA. CFD may allow us to obtain adequate rheological conditions conducive to achieving the best clinical results.
引用
收藏
页码:1096 / 1101
页数:6
相关论文
共 44 条
[1]   Prospective randomized study of carotid endarterectomy with polytetrafluoroethylene versus collagen-impregnated Dacron (Hemashield) patching: Perioperative (30-day) results [J].
AbuRahma, AF ;
Hannay, RS ;
Khan, JH ;
Robinson, PA ;
Hudson, JK ;
Davis, EA .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (01) :125-130
[2]   A randomized trial of synthetic patch versus direct primary closure in carotid endarterectomy [J].
Al-Rawi, Pippa G. ;
Turner, Carole L. ;
Waran, Vicknes ;
Ng, Ivan ;
Kirkpatrick, Peter J. .
NEUROSURGERY, 2006, 59 (04) :822-828
[3]  
[Anonymous], 2004, COCHRANE DB SYST REV, DOI DOI 10.1002/14651858.CD000071.PUB2
[4]   PATCH ANGIOPLASTY IN CAROTID ENDARTERECTOMY - ADVANTAGES, CONCERNS, AND CONTROVERSIES [J].
AWAD, IA ;
LITTLE, JR .
STROKE, 1989, 20 (03) :417-422
[5]  
Baráth K, 2004, AM J NEURORADIOL, V25, P1750
[6]   Analysis of haemodynamic disturbance in the atherosclerotic carotid artery using computational fluid dynamics [J].
Birchall, D ;
Zaman, A ;
Hacker, J ;
Davies, G ;
Mendelow, D .
EUROPEAN RADIOLOGY, 2006, 16 (05) :1074-1083
[7]   Systematic review of randomized controlled trials of patch angioplasty versus primary closure and different types of patch materials during carotid endarterectomy [J].
Bond, R ;
Rerkasem, K ;
Naylor, AR ;
AbuRahma, FF ;
Rothwell, PM .
JOURNAL OF VASCULAR SURGERY, 2004, 40 (06) :1126-1135
[8]   Clinical results of carotid artery stenting compared with carotid endarterectomy [J].
Brahmanandam, Soma ;
Ding, Eric L. ;
Conte, Michael S. ;
Belkin, Michael ;
Nguyen, Louis L. .
JOURNAL OF VASCULAR SURGERY, 2008, 47 (02) :343-349
[9]   Parametric geometry exploration of the human carotid artery bifurcation [J].
Bressloff, Nell W. .
JOURNAL OF BIOMECHANICS, 2007, 40 (11) :2483-2491
[10]   Results using a self-expanding stent alone in the treatment of severe symptomatic carotid bifurcation stenosis [J].
Bussiere, Miguel ;
Pelz, David M. ;
Kalapos, Paul ;
Lee, Donald ;
Gulka, Irene ;
Leung, Andrew ;
Lownie, Stephen P. .
JOURNAL OF NEUROSURGERY, 2008, 109 (03) :454-460