Wireless Readout of Passive LC Sensors

被引:150
作者
Nopper, Reinhard [1 ]
Niekrawietz, Remigius [1 ]
Reindl, Leonhard [2 ]
机构
[1] Robert Bosch GmbH, Microsyst Technol Dept, Corp Sector Res & Adv Engn, D-70839 Gerlingen, Germany
[2] Univ Freiburg, Inst Microsyst Technol IMTEK, Lab Elect Instrumentat, D-79110 Freiburg, Germany
关键词
Capacitance transducers; inductive coupling; LC circuits; remote sensing; resonance detection; telemetry; PRESSURE TRANSENSOR; CIRCUIT;
D O I
10.1109/TIM.2009.2032966
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper reports simple yet precise equations for automated wireless measurement of the resonance frequency, Q-factor, and coupling coefficient of inductively coupled passive resonant LC circuits. This allows remote sensing of all physical and chemical quantities that can be measured with capacitance transducers. Formerly reported front-end circuit concepts for wireless sensor readout, i.e., phase dip measurement and the dip meter, are subsequently discussed. It is shown that, due to fundamental system limitations, the formerly reported circuit concepts are not applicable if the distance between the sensor and the readout electronic circuit becomes too small, resulting in large coupling coefficients. Therefore, we present an improved concept for an analog front-end circuit of the readout system that overcomes these limitations and hence allows wireless sensor readout under a wider range of operating distances.
引用
收藏
页码:2450 / 2457
页数:8
相关论文
共 13 条
[1]   A self-resonant frequency-modulated micromachined passive pressure transensor [J].
Baldi, A ;
Choi, W ;
Ziaie, B .
IEEE SENSORS JOURNAL, 2003, 3 (06) :728-733
[2]   Wireless, passive, resonant-circuit, inductively coupled, inductive strain sensor [J].
Butler, JC ;
Vigliotti, AJ ;
Verdi, FW ;
Walsh, SM .
SENSORS AND ACTUATORS A-PHYSICAL, 2002, 102 (1-2) :61-66
[4]   A readout circuit for an intra-ocular pressure sensor [J].
Coosemans, J ;
Catrysse, M ;
Puers, R .
SENSORS AND ACTUATORS A-PHYSICAL, 2004, 110 (1-3) :432-438
[5]  
COOSEMANS J, 2002, P EUROSENSORS, V16, P533
[6]   Wireless micromachined ceramic pressure sensor for high-temperature applications [J].
Fonseca, MA ;
English, JM ;
von Arx, M ;
Allen, MG .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2002, 11 (04) :337-343
[7]   High-quality factor electrolyte insulator silicon capacitor for wireless chemical sensing [J].
Garcia-Canton, J. ;
Merlos, A. ;
Baldi, A. .
IEEE ELECTRON DEVICE LETTERS, 2007, 28 (01) :27-29
[8]   A PRECISE 4-QUADRANT MULTIPLIER WITH SUBNANOSECOND RESPONSE [J].
GILBERT, B .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1968, SC 3 (04) :365-&
[9]   A passive humidity monitoring system for in situ remote wireless testing of micropackages [J].
Harpster, TJ ;
Hauvespre, S ;
Dokmeci, MR ;
Najafi, K .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2002, 11 (01) :61-67
[10]   A new passive telemetry LC pressure and temperature sensor optimized for TPMS [J].
Nabipoor, M. ;
Majlis, B. Y. .
INTERNATIONAL MEMS CONFERENCE 2006, 2006, 34 :770-775