Influence of the Light Source and Bleaching Gel on the Efficacy of the Tooth Whitening Process

被引:35
作者
Dominguez, Arantza [1 ]
Antonio Garcia, Juan [2 ]
Costela, Angel [1 ]
Gomez, Clara [1 ]
机构
[1] CSIC, Inst Quim Fis Rocasolano, Dept Laser Chem, E-28006 Madrid, Spain
[2] UCM, Fac Dent, Dept Stomatol 3, Madrid, Spain
关键词
PULP CHAMBER TEMPERATURE; IN-VITRO; LASER IRRADIATION; DIODE-LASER; ROOT CANALS; TEETH; COLOR; SURFACE; PEROXIDE; INCREASE;
D O I
10.1089/pho.2009.2751
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To examine the whitening efficacy of three whitening agents in combination with six different photoactivation systems. Background: Bleaching techniques have achieved significant advances using photoactivation with coherent or incoherent radiation sources. Methods: Quick White, Ena White Power, and Opalescence Endo bleaching agents, all containing 35% hydrogen peroxide, were stimulated with halogen lamp, light-emitting diode (LED), low-power diode laser, and neodymium: yttrium-aluminum-garnet (Nd:YAG), second harmonic of Nd:YAG, and Er:YAG lasers. One hundred twenty-six extracted human incisors were treated, and color change, pulpal temperature, and enamel morphological alterations were evaluated. Results: Only the groups that were photoactivated using a diode laser, halogen lamp, and LED showed statistically significant differences (p < 0.005) in color change when compared with the control group (without photoactivation). All whitening protocols were safe with regard to the increase in pulpal temperature. Scanning electron microscopy showed no evidence of effects on the integrity of enamel. Conclusions: The source of irradiation is more relevant than the bleaching agent for efficient tooth whitening. In addition, photoactivation with LED was found to be the best choice: it yielded significant change in color with only a minor increase in pulpal temperature.
引用
收藏
页码:53 / 59
页数:7
相关论文
共 33 条
[1]  
Browning William D, 2003, J Esthet Restor Dent, V15 Suppl 1, pS13, DOI 10.1111/j.1708-8240.2003.tb00314.x
[2]   In vitro efficacy and risk for adverse effects of light-assisted tooth bleaching [J].
Bruzell, Ellen M. ;
Johnsen, Bjorn ;
Aalerud, Tommy Nakken ;
Dahl, Jon E. ;
Christensen, Terje .
PHOTOCHEMICAL & PHOTOBIOLOGICAL SCIENCES, 2009, 8 (03) :377-385
[3]   External bleaching therapy with activation by heat, light or laser - A systematic review [J].
Buchalla, Wolfgang ;
Attin, Thomas .
DENTAL MATERIALS, 2007, 23 (05) :586-596
[4]   IN VITRO STUDY OF THE PULP CHAMBER TEMPERATURE RISE DURING LIGHT-ACTIVATED BLEACHING [J].
Carrasco, Thaise Graciele ;
Carrasco-Guerisoli, Laise Daniela ;
Froner, Izabel Cristina .
JOURNAL OF APPLIED ORAL SCIENCE, 2008, 16 (05) :355-359
[5]   The tooth-whitening revolution [J].
Christensen, GJ .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2002, 133 (09) :1277-1279
[6]   Clinical evaluation of a novel whitening gel, containing 6% hydrogen peroxide and a standard fluoride toothpaste [J].
Collins, LZ ;
Maggio, B ;
Liebman, J ;
Blanck, M ;
Lefort, S ;
Waterfield, P ;
Littlewood, D ;
Naeeni, M ;
Schäfer, F .
JOURNAL OF DENTISTRY, 2004, 32 :13-17
[7]   Comparison of temperature increase in in vitro human tooth pulp by different light sources in the dental whitening process [J].
Coutinho, Daniela Soares ;
Silveira, Landulfo, Jr. ;
Nicolau, Renata Amadei ;
Zanin, Fatima ;
Brugnera, Aldo, Jr. .
LASERS IN MEDICAL SCIENCE, 2009, 24 (02) :179-185
[8]   Optical properties and surface structure comparison of tooth whitening using four laser system and chemical action agents [J].
Dostalova, TA ;
Jelinkova, H ;
Koranda, P ;
Nemec, M ;
Sulc, J ;
Housova, D ;
Myiagi, M ;
Kokta, MR .
LASERS IN DENTISTRY IX, 2003, 4950 :37-45
[9]   Pulpal temperature rise during light-activated bleaching [J].
Eldeniz, AU ;
Usumez, A ;
Usumez, S ;
Ozturk, N .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 72B (02) :254-259
[10]  
Gerlach Robert W, 2002, Compend Contin Educ Dent, V23, P16