Toward adaptive radiotherapy for head and neck patients: Uncertainties in dose warping due to the choice of deformable registration algorithm

被引:74
|
作者
Veiga, Catarina [1 ]
Lourenco, Ana Monica [1 ,2 ]
Mouinuddin, Syed [3 ]
van Herk, Marcel [4 ]
Modat, Marc [5 ]
Ourselin, Sebastien [5 ]
Royle, Gary [1 ]
McClelland, Jamie R. [5 ]
机构
[1] UCL, Dept Med Phys & Biomed Engn, Radiat Phys Grp, London WC1E 6BT, England
[2] Natl Phys Lab, Acoust & Ionizing Radiat Team, Teddington TW11 0LW, Middx, England
[3] Univ Coll London Hosp, Dept Radiotherapy, London NW1 2BU, England
[4] Netherlands Canc Inst, Dept Radiat Oncol, NL-1066 CX Amsterdam, Netherlands
[5] UCL, Ctr Med Image Comp, Dept Med Phys & Biomed Engn, London WC1E 6BT, England
基金
英国工程与自然科学研究理事会;
关键词
adaptive radiotherapy; cone-beam CT; deformable registration; dose warping; head and neck; inverse consistency; IMAGE REGISTRATION; RADIATION-THERAPY; DEFORMING ANATOMY; SPATIAL ACCURACY; VECTOR FIELD; FRAMEWORK; CONSISTENCY; DELINEATION; VALIDATION; TRACKING;
D O I
10.1118/1.4905050
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aims of this work were to evaluate the performance of several deformable image registration (DIR) algorithms implemented in our in-house software (NiftyReg) and the uncertainties inherent to using different algorithms for dose warping. Methods: The authors describe a DIR based adaptive radiotherapy workflow, using CT and conebeam CT (CBCT) imaging. The transformations that mapped the anatomy between the two time points were obtained using four different DIR approaches available in NiftyReg. These included a standard unidirectional algorithm and more sophisticated bidirectional ones that encourage or ensure inverse consistency. The forward (CT-to-CBCT) deformation vector fields (DVFs) were used to propagate the CT Hounsfield units and structures to the daily geometry for "dose of the day" calculations, while the backward (CBCT-to-CT) DVFs were used to remap the dose of the day onto the planning CT (pCT). Data from five head and neck patients were used to evaluate the performance of each implementation based on geometrical matching, physical properties of the DVFs, and similarity between warped dose distributions. Geometrical matching was verified in terms of dice similarity coefficient (DSC), distance transform, false positives, and false negatives. The physical properties of the DVFs were assessed calculating the harmonic energy, determinant of the Jacobian, and inverse consistency error of the transformations. Dose distributions were displayed on the pCT dose space and compared using dose difference (DD), distance to dose difference, and dose volume histograms. Results: All the DIR algorithms gave similar results in terms of geometrical matching, with an average DSC of 0.85 +/- 0.08, but the underlying properties of the DVFs varied in terms of smoothness and inverse consistency. When comparing the doses warped by different algorithms, we found a root mean square DD of 1.9% +/- 0.8% of the prescribed dose (pD) and that an average of 9% +/- 4% of voxels within the treated volume failed a 2% pD DD-test (DD2%-pp). Larger DD2%-pp was found within the high dose gradient (21% +/- 6%) and regions where the CBCT quality was poorer (28% +/- 9%). The differences when estimating the mean and maximum dose delivered to organs-at-risk were up to 2.0% pD and 2.8% pD, respectively. Conclusions: The authors evaluated several DIR algorithms for CT-to-CBCT registrations. In spite of all methods resulting in comparable geometrical matching, the choice of DIR implementation leads to uncertainties in dose warped, particularly in regions of high gradient and/or poor imaging quality. (C) 2015 Author(s).
引用
收藏
页码:760 / 769
页数:10
相关论文
共 50 条
  • [1] Towards adaptive radiotherapy for head and neck patients: validation of an in-house deformable registration algorithm
    Veiga, C.
    McClelland, J.
    Moinuddin, S.
    Ricketts, K.
    Modat, M.
    Ourselin, S.
    D'Souza, D.
    Royle, G.
    XVII INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY (ICCR 2013), 2014, 489
  • [2] Evaluation of deformable image registration methods for dose monitoring in head and neck adaptive radiotherapy
    Rigaud, B.
    Simon, A.
    Castelli, J.
    Gobeli, M.
    Arango, J. D. Ospina
    Cazoulat, G.
    Henry, O.
    Haigron, P.
    De Crevoisier, R.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S488 - S489
  • [3] Toward adaptive radiotherapy for head and neck patients: Feasibility study on using CT-to-CBCT deformable registration for "dose of the day" calculations
    Veiga, Catarina
    McClelland, Jamie
    Moinuddin, Syed
    Lourenco, Ana
    Ricketts, Kate
    Annkah, James
    Modat, Marc
    Ourselin, Sebastien
    D'Souza, Derek
    Royle, Gary
    MEDICAL PHYSICS, 2014, 41 (03)
  • [4] The Accuracy or Deformable Registration for Adaptive Radiotherapy of Head and Neck Cancer
    van Kranen, S.
    Mencarelli, A.
    van Beek, S.
    Rasch, C.
    Sonke, J.
    van Herk, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S573 - S573
  • [5] Evaluation of the Block Matching deformable registration algorithm in the field of head-and-neck adaptive radiotherapy
    Huger, S.
    Graff, P.
    Harter, V.
    Marchesi, V.
    Royer, P.
    Diaz, J. C.
    Aouadi, S.
    Wolf, D.
    Peiffert, D.
    Noel, A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (03): : 301 - 308
  • [6] The Role of Regularization in Deformable Image Registration for Head and Neck Adaptive Radiotherapy
    Ciardo, D.
    Peroni, M.
    Riboldi, M.
    Alterio, D.
    Baroni, G.
    Orecchia, R.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2013, 12 (04) : 323 - 331
  • [7] The impact of robustness of deformable image registration on contour propagation and dose accumulation for head and neck adaptive radiotherapy
    Zhang, Lian
    Wang, Zhi
    Shi, Chengyu
    Long, Tengfei
    Xu, X. George
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 185 - 194
  • [8] Evaluation of Deformable Image Registration Methods for Dose Monitoring in Head and Neck Radiotherapy
    Rigaud, Bastien
    Simon, Antoine
    Castelli, Joel
    Gobeli, Maxime
    Arango, Juan-David Ospina
    Cazoulat, Guillaume
    Henry, Olivier
    Haigron, Pascal
    De Crevoisier, Renaud
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [9] Deformable Image Registration Based Delivered Dose Estimation for Head and Neck Radiotherapy
    Kumarasiri, A.
    Liu, C.
    Chetvertkov, M.
    Gordon, J.
    Siddiqui, F.
    Chetty, I.
    Kim, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 191 - 192
  • [10] DEFORMABLE REGISTRATION FOR ADAPTIVE RADIOTHERAPY OF HEAD AND NECK CANCER GETS WORSE IN TIME
    Rasch, C.
    Mencarelli, A.
    van Kranen, S. R.
    Hamming-Vrieze, O.
    van Beek, S.
    van Herk, M.
    Sonke, J. J.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S42 - S42